SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-106944"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-106944" > Clinical implicatio...

  • Flejmer, Anna M.Linköpings universitet,Avdelningen för kliniska vetenskaper,Hälsouniversitetet (författare)

Clinical implications of the ISC technique for breast cancer radiotherapy and comparison with clinical recommendations

  • Artikel/kapitelEngelska2014

Förlag, utgivningsår, omfång ...

  • International Institute of Anticancer Research,2014
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-106944
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-106944URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Purpose: The project studied the implications of using the irregular surface compensator (ISC) technique in comparison to three-dimensional conformal radiation therapy (3D-CRT) for breast cancer treatment. ISC is an electronic compensation algorithm that modulates the fluence across the radiation fields to compensate for irregularly shaped surfaces and deliver a homogeneous dose to a compensation plane. Methods: Ten breast cancer patients (five left- and five right-sided) were planned with both techniques. The planning was done for 50 Gy in 25 fractions with 2 Gy per fraction in all patients. Physical parameters such as doses to the clinical target volume (CTV-T) and the planned target volume (PTV), heterogeneity index and doses to lung and heart were determined and compared for the treatment plans. Results: The ISC technique led to significantly better coverage of the CTV-T and PTV in almost all patients with statistically significant better homogeneity of the dose distribution. The contralateral lung and the heart receive the same doses with both ISC and 3D-CRT plans. However, ISC showed a trend towards decreasing the volumes of the ipsilateral lung irradiated with high doses. Consequently this led to better compliance with the national recommendations for breast radiotherapy. Conclusion: The ISC technique leads to an improvement of the target coverage and the radiation burden of the ipsilateral lung thus allowing better compliance with the national recommendations and increasing the potential for improved quality of life for breast cancer patients. It should therefore be preferred over 3D-CRT for breast cases with difficult dose homogeneity to the PTV or CTV-T.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Josefsson, DanÖstergötlands Läns Landsting,Linköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet,Radiofysikavdelningen US(Swepub:liu)danjo94 (författare)
  • Nilsson, MatsFuturum - Academy for Health and Care, Jönköping (författare)
  • Stenmarker, MargarethaFuturum - Academy for Health and Care, Jönköping (författare)
  • Dasu, AlexandruÖstergötlands Läns Landsting,Linköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet,Radiofysikavdelningen US(Swepub:liu)aleda92 (författare)
  • Linköpings universitetAvdelningen för kliniska vetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Anticancer Research: International Institute of Anticancer Research34:7, s. 3563-35680250-70051791-7530

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy