SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:31329c0e-5c8b-400e-84d1-0bbdac852574"
 

Sökning: onr:"swepub:oai:research.chalmers.se:31329c0e-5c8b-400e-84d1-0bbdac852574" > Elevation angle ali...

Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements

Moseev, D. (författare)
Max Planck Gesellschaft zur Förderung der Wissenschaften e.V. (MPG),Max Planck Society for the Advancement of Science (MPG)
Meo, F. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Korsholm, S. B. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
visa fler...
Bindslev, H. (författare)
Århus Universitet,Aarhus University
Furtula, Vedran, 1981 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Kantor, M. (författare)
Forschungszentrum Jülich GmbH,Russian Academy of Sciences
Leipold, F. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Michelsen, P. K. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Nielsen, S. K. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Salewski, M. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Stejner, M. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
visa färre...
Max Planck Gesellschaft zur Förderung der Wissenschaften eV. (MPG) Danmarks Tekniske Universitet (creator_code:org_t)
AIP Publishing, 2012
2012
Engelska.
Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 1089-7623 .- 0034-6748. ; 83:10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Localized measurements of the fast ion velocity distribution function and the plasma composition measurements are of significant interest for the fusion community. Collective Thomson scattering (CTS) diagnostics allow such measurements with spatial and temporal resolution. Localized measurements require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic on TEXTOR without a source of probing radiation in discharges with sawtooth oscillations, an elevation angle misalignment of 0.9 degrees was found with an accuracy of 0.25 degrees.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

radiation
ion temperature

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy