Sökning: onr:"swepub:oai:DiVA.org:liu-21206" > Standardized evalua...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 05811naa a2200721 4500 | |
001 | oai:DiVA.org:liu-21206 | |
003 | SwePub | |
008 | 090930s2009 | |||||||||||000 ||eng| | |
009 | oai:DiVA.org:kth-258836 | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-212062 URI |
024 | 7 | a https://doi.org/10.1016/j.media.2009.06.0032 DOI |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-2588362 URI |
040 | a (SwePub)liud (SwePub)kth | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Schaap, M.u Biomedical Imaging Group Rotterdam, The Netherlands4 aut |
245 | 1 0 | a Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms |
264 | 1 | b Elsevier,c 2009 |
338 | a print2 rdacarrier | |
500 | a QC 20190913 | |
520 | a Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available, and (4) 13 coronary artery centerline extraction algorithms, implemented by different research groups, are quantitatively evaluated and compared. The presented evaluation framework is made available to the medical imaging community for benchmarking existing or newly developed coronary centerline extraction algorithms. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk bildbehandling0 (SwePub)206032 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Image Processing0 (SwePub)206032 hsv//eng |
653 | a Centerline extraction; Computed tomography; Coronaries; Standardized evaluation; Tracking | |
653 | a MEDICINE | |
653 | a MEDICIN | |
700 | 1 | a Metz, C.T.u Biomedical Imaging Group Rotterdam, The Netherlands,Universidad Politécnica de Madrid, Spain4 aut |
700 | 1 | a van Walsum, T.u Biomedical Imaging Group Rotterdam, The Netherlands4 aut |
700 | 1 | a van der Giessen, A.G.u Biomedical Imaging Group Rotterdam, The Netherlands4 aut |
700 | 1 | a Weustink, A.C.u Erasmus MC, Rotterdam, The Netherlands4 aut |
700 | 1 | a Mollet, N.R.u Erasmus MC, Rotterdam, The Netherlands4 aut |
700 | 1 | a Bauer, C.u Graz University of Technology, Austria4 aut |
700 | 1 | a Bogunovic, H.u Center for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), Barcelona, Spain4 aut |
700 | 1 | a Castro, C.u Universidad Politécnica de Madrid, Spain,MeVis Research, Bremen, Germany4 aut |
700 | 1 | a Deng, X.u Siemens Corporate Research, Princeton, NJ, USA4 aut |
700 | 1 | a Dikici, E.u University of Florida College of Medicine, Jacksonville, FL, USA4 aut |
700 | 1 | a O'Donnell, T.u Siemens Corporate Research, Princeton, NJ, USA4 aut |
700 | 1 | a Frenay, M.u Leiden University Medical Center, The Netherlands4 aut |
700 | 1 | a Friman, O.u MeVis Research, Bremen, Germany4 aut |
700 | 1 | a Hoyos, M.H.u Universidad de los Andes, Bogota, Colombia4 aut |
700 | 1 | a Kitslaar, P.H.u Leiden University Medical Center, The Netherlands4 aut |
700 | 1 | a Krissian, K.u University of Las Palmas of Gran Canaria, Spain,Childrens Hospital Boston, MA, USA4 aut |
700 | 1 | a Kuhnel, C.u MeVis Research, Bremen, Germany4 aut |
700 | 1 | a Luengo-Oroz, M.A.u Universidad Politécnica de Madrid, Spain4 aut |
700 | 1 | a Orkisz, M.u Université de Lyon, France4 aut |
700 | 1 | a Smedby, Örjanu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping4 aut0 (Swepub:liu)orjsm14 |
700 | 1 | a Styner, M.u University of North Carolina, Chapel Hill, NC, USA4 aut |
700 | 1 | a Szymczak, A.u Colorado School of Mines, Golden, CO, USA4 aut |
700 | 1 | a Tek, H.u Siemens Corporate Research, Princeton, NJ, USA4 aut |
700 | 1 | a Wang, Chunliangu Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Linköping Univ., Linköping, Sweden4 aut0 (Swepub:kth)u1tbkeej |
700 | 1 | a Warfield, S.K.u Childrens Hospital Boston, MA, USA4 aut |
700 | 1 | a Zambal, S.u VRVis Research Center for Virtual Reality and Visualization, Vienna, Austria4 aut |
700 | 1 | a Zhang, Y.u The Methodist Hospital Research Institute, Houston, TX, USA4 aut |
700 | 1 | a Krestin, G.P.u Erasmus MC, Rotterdam, The Netherlands4 aut |
700 | 1 | a Niessen, W.J.u Erasmus MC, Rotterdam, The Netherlands4 aut |
710 | 2 | a Biomedical Imaging Group Rotterdam, The Netherlandsb Universidad Politécnica de Madrid, Spain4 org |
773 | 0 | t Medical Image Analysisd : Elsevierg 13:5, s. 701-714q 13:5<701-714x 1361-8415x 1361-8423 |
856 | 4 | u https://cdr.lib.unc.edu/downloads/cn69mc016 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-21206 |
856 | 4 8 | u https://doi.org/10.1016/j.media.2009.06.003 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-258836 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy