SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0034 6748 OR L773:1089 7623
 

Sökning: L773:0034 6748 OR L773:1089 7623 > Imaging surface pla...

Imaging surface plasmon resonance sensor based on multiple wavelengths : Sensitivity considerations

Johansen, K (författare)
Arwin, Hans (författare)
Linköpings universitet,Tekniska högskolan,Tillämpad optik
Lundström, Ingemar (författare)
Linköpings universitet,Tekniska högskolan,Tillämpad Fysik
visa fler...
Liedberg, Bo (författare)
Linköpings universitet,Tekniska högskolan,Sensorvetenskap och Molekylfysik
visa färre...
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Review of Scientific Instruments. - 0034-6748 .- 1089-7623. ; 71:9, s. 3530-3538
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A new, multiple wavelength surface plasmon resonance apparatus for imaging applications is presented. It can be used for biosensing, e.g., for monitoring of chemical and biological reactions in real time with label-free molecules. A setup with a fixed incident angle in the Kretschmann configuration with gold as the supporting metal is described, both theoretically and experimentally. Simulations of the sensor response based on independently recorded optical (ellipsometric) data of gold show that the sensitivity for three-dimensional recognition layers (bulk) increases with increasing wavelength. For two-dimensional recognition layers (adlayer) maximum sensitivity is obtained within a limited wavelength range. In this situation, the rejection of bulk disturbances, e.g., emanating from temperature variations, decreases, with increasing wavelength. For imaging surface plasmon resonance the spatial resolution decreases with increasing wavelength. Hence, there is always a compromise between spatial resolution, bulk disturbance rejection, and sensitivity. Most importantly, by simultaneously using multiple wavelengths, it is possible to maintain a high sensitivity and accuracy over a large dynamic range. Furthermore, our simulations show that the sensitivity is independent of the refractive index of the prism. (C) 2000 American Institute of Physics. [S0034-6748(00)02909-9].

Nyckelord

TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy