SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:0250 7005 OR L773:1791 7530
 

Sökning: L773:0250 7005 OR L773:1791 7530 > Dosimetric and radi...

Dosimetric and radiobiological evaluation of hybrid inverse planning and optimization for cervical cancer brachytherapy

dos Santos Matias, Lucílio (författare)
Stockholms universitet,Fysikum,Eduardo Mondlane University, Mozambique
Palmqvist, Tomas (författare)
Wolke, Jeanette (författare)
visa fler...
Nilsson, Josef (författare)
Beskow, Catharina (författare)
Karolinska Institutet
Maphossa, Alexandre M. (författare)
Toma-Dasu, Iuliana (författare)
Karolinska Institutet,Stockholms universitet,Fysikum
visa färre...
 (creator_code:org_t)
2015
2015
Engelska.
Ingår i: Anticancer Research. - 0250-7005 .- 1791-7530. ; 35:11, s. 6091-6096
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Aim: To compare manual graphical optimization (GrO) with hybrid inverse planning optimization (HIPO) of cervical cancer brachytherapy treatment plans using physical and radiobiological tools. Patients and Methods: Ten patients suffering from cervical cancer, treated with pulsed brachytherapy using GrO plans, were included in the study. For each patient, four different HIPO class solutions with different dose objectives to the target and constraints to the organs at risk (OAR) produced four optimized plans, that were each compared to the corresponding GrO plan. Class solution in HIPO is a set of parameters consisting of dose constraints and penalty weights, which are used for optimization. The comparison was based on the following dosimetric parameters: conformity index (COIN), minimum dose received by 98% and 90% of the high-risk clinical target volume (represented by D98 and D90, respectively), and the minimum dose imparted to 2 cm3 (D2cm3) of the most exposed OAR i.e. bladder, sigmoid colon or rectum. The HIPO class solution which produced plans with overall better dosimetric parameters was selected and its plans were compared with manual GrO plans from a radiobiological viewpoint based on the calculated complication-free tumour control probability, P+. Results: The average COIN for the GrO and the selected HIPO plans were 0.22 and 0.30, respectively. The median COIN of the GrO and the HIPO plans were not statistically different (p>0.05, Wilcoxon test). The relative percentage difference of the averaged P+ values between the HIPO and GrO plans evaluated together with the external beam radiation therapy plans was 0.01%, 0.37% and 0.98% for the bladder, sigmoid colon and rectum, respectively. The lowest P+ value for all the plans was 98.44% for sigmoid colon. Conclusion: HIPO presented comparable results in relation to manual planning with respect to dosimetric and radiobiological parameters.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

Pulsed brachytherapy
optimization
radiobiology
treatment planning
HIPO

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy