Volumetric and dosimetric evaluation of radiation treatment plans: radiation conformity index

Knöös, Tommy (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Kristensen, Ingrid (författare)
Lund University,Lunds universitet,Bröstcancer-genetik,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Breastcancer-genetics,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
Nilsson, Per (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
1998
1998
Engelska.
Ingår i: International Journal of Radiation Oncology, Biology, Physics. - 0360-3016. ; 42:5, s. 1169-1176
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: The use of conformal radiation therapy has grown substantially during the last years since three-dimensional (3D) treatment planning systems with beams-eye-view planning has become commercially available. We studied the degree of conformity reached in clinical routines for some common diagnoses treated at our department by calculating a radiation conformity index (RCI). METHODS AND MATERIALS: The radiation conformity index, determined as the ratio between the target volume (PTV) and the irradiated volume, has been evaluated for 57 patients treated with 3D treatment plans. RESULTS AND CONCLUSION: The RCI was found to vary from 0.3 to 0.6 (average 0.4), a surprisingly low figure. The higher RCI is typical for pelvic treatments (e.g., prostate) and stereotactic treatments. The lower RCI is found for extended tumors, such as mammary carcinomas where the adjacent nodes are included. The latter is also valid for most lung cancer patients studied. The RCI gives a consistent method for quantifying the degree of conformity based on isodose surfaces and volumes. Care during interpretation of RCI must always be taken, since small changes in the minimum dose can dramatically change the treated volume.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Three-dimensional
Conformal therapy
Treatment planning
Radiation therapy
Conformity index

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Knöös, Tommy
Kristensen, Ingr ...
Nilsson, Per
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
International Jo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy