Sökning: L773:1969 6213 >
Comparison of two d...
Comparison of two drug-eluting balloons : a report from the SCAAR registry
-
- Bondesson, Per (författare)
- Skåne University Hospital, Lund University, Sweden
-
- Lagerqvist, Bo (författare)
- Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),kardiologi,Uppsala University, Sweden
-
- James, Stefan K. (författare)
- Uppsala universitet,Uppsala kliniska forskningscentrum (UCR),kardiologi,Uppsala University, Sweden
-
visa fler...
-
- Olivecrona, Göran (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital, Lund University, Sweden
-
- Venetsanos, Dimitrios (författare)
- Östergötlands Läns Landsting,Kardiologiska kliniken US
-
- Harnek, Jan (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital, Lund University, Sweden
-
visa färre...
-
(creator_code:org_t)
- Europa Edition, 2012
- 2012
- Engelska.
-
Ingår i: EuroIntervention. - : Europa Edition. - 1774-024X .- 1969-6213. ; 8:4, s. 444-449
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://urn.kb.se/re...
-
https://doi.org/10.4...
-
https://urn.kb.se/re...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- Aims: Recently, drug-eluting balloons have received a guideline class IIa recommendation in the treatment of in-stent restenosis after bare metal stent implantation. It is not known if different balloons perform equally. Using a large real world registry, restenosis frequency was reported for two drug-eluting balloons. less thanbrgreater than less thanbrgreater thanMethods and results: From April 2009 until September 2011, 1,129 patients were treated with paclitaxel-eluting balloons in Sweden. Mean follow-up was 328 +/- 210 days. Nine hundred and nineteen patients were treated with a balloon using a contrast agent as a drug-carrier and 217 with a balloon without a contrast agent as a drug-carrier. The indications were predominantly de novo (45.4%) or in-stent restenotic (51.8%) lesions. The overall incidence of restenosis at six months was 3.4% with the paclitaxel balloon using a contrast agent as carrier, compared with 12.5% with the paclitaxel-eluting balloon without a carrier (risk ratio: 0.42; 95% confidence interval [CI] [0.26-0.68]). After adjusting for indications, lesion types and procedural factors, the risk ratio was 0.39; 95% CI (0.24-0.65). less thanbrgreater than less thanbrgreater thanConclusions: This observational study from a large real world population shows a major difference between two paclitaxel-eluting balloons. The findings suggest that there are no class effects for drug-eluting balloons and factors other than the drug may be important for the clinical effect.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- drug-eluting balloon
- restenosis
- in-stent restenosis
- paclitaxel
- revascularisation
- TECHNOLOGY
- TEKNIKVETENSKAP
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas