Deflections of an implant-supported cantilever beam subjected to vertically directed loads : In vitro measurements in three dimensions using an optoelectronic method. II Analysis of methodological errors.

Cassel, Björn (författare)
Lundgren, Dan (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Karlsson, Dan (författare)
Jönköping University,HHJ, Avdelningen för rehabilitering,HHJ. Ortopedteknisk plattform
 (creator_code:org_t)
2010-12-02
2010
Engelska.
Ingår i: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 22:6, s. 645-650
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Aim: The aim of this study was to evaluate the accuracy, i.e. trueness (validity) and precision (repeatability) for load-dependent deflections in three dimensions of an implant-supported cantilever beam obtained with an optoelectronic motion analysis system compared with a well-known reference method.Materials and methods: A cantilever beam with a length of 22 mm (roughly corresponding to the width of two premolars) was screw-connected to an implant–abutment unit stiffly anchored in a steel plate. The positional changes of beam-end were measured when the beam-end step by step was subjected to four loads, 15.5–40.1 N. This measurement procedure was repeated to comprise six consecutive measurements. The trueness of the method was estimated by comparing the data obtained for vertical deflections with those from a reference method where a hydraulic test system was used to measure the load-deflection ratios of the same beam when subjected to the four mentioned vertical loads.Results: All applied transducer-mediated loads had accuracies (truenesses and repeatabilities below 0.05%). Also, the trueness and precision of the reference method, regarding both movements (deflections) of tested objects and magnitude of applied loads, were tested and found to be high, not exceeding 0.5%.The optoelectronic method however underestimated the smallest vertical deflections for the cantilever beam when compared with the data obtained from the reference method. The underestimation was 26.4%, 15.5% and 8.6% for loads 15.5, 26.6 and 32.6 N, respectively, while there was a slight overestimation of 1.2% for 40.1 N. The precision for the optoelectronic method was found to be for z-axis 1.8 μm, y-axis 3.8 μm and x-axis 1.9 μm.Conclusion: It can be concluded that the trueness (validity) for the optoelectronic method is very high for deflections above 143 μm. The precision (repeatability) of the optoelectronic method was found to be very high.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

3D deflections
biomechanics
cantilever loads
methodological errors
motion analysis system
screw joints

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Cassel, Björn
Lundgren, Dan
Karlsson, Dan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Clinical Oral Im ...
Av lärosätet
Jönköping University
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy