SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-8358"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-8358" > Automated Nano-Elec...

Automated Nano-Electrospray Mass Spectrometry for Protein-Ligand Screening by Noncovalent Interaction Applied to Human H-FABP and A-FABP

Benkestock, Kurt (författare)
KTH,Kemi
Van Pelt, C. K. (författare)
Advion BioSci Inc, Ithaca, NY USA
Åkerud, Tomas (författare)
Lund University,Lunds universitet,Biofysikalisk kemi,Centrum för Molekylär Proteinvetenskap,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biophysical Chemistry,Center for Molecular Protein Science,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH,Lund Univ, Dept Biophys Chem
visa fler...
Sterling, A. (författare)
Advion BioSci Ltd, Norwich, Norfolk England
Edlund, Per Olof (författare)
Biovitrum AB, Analyt Sci
Roeraade, Johan (författare)
KTH,Kemi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2003
2003
Engelska.
Ingår i: Journal of Biomolecular Screening. - : Elsevier BV. - 1087-0571 .- 1552-454X. ; 8:3, s. 247-256
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A method for ligand screening by automated nano-electrospray ionization mass spectrometry (nano-ESI/MS) is described. The core of the system consisted of a chip-based platform for automated sample delivery from a 96-well plate and subsequent analysis based on noncovalent interactions. Human fatty acid binding protein, H-FABP (heart) and A-FABP (adipose), with small potential ligands was analyzed. The technique has been compared with a previously reported method based on nuclear magnetic resonance (NMR), and excellent correlation with the found hits was obtained. In the current MS screening method, the cycle time per sample was 1.1 min, which is approximately 50 times faster than NMR for single compounds and approximately 5 times faster for compound mixtures. High reproducibility was achieved, and the protein consumption was in the range of 88 to 100 picomoles per sample. Furthermore, a novel protocol for preparation of A-FABP without the natural ligand is presented. The described screening approach is suitable for ligand screening very early in the drug discovery process before conventional high-throughput screens (HTS) are developed and/or used as a secondary screening for ligands identified by HTS.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
NATURVETENSKAP  -- Kemi -- Fysikalisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Physical Chemistry (hsv//eng)

Nyckelord

automated nano-electrospray; noncovalent; screening; FABP; ACID-BINDING PROTEINS; COMPLEXES; MICRODIALYSIS; RESOLUTION; ADIPOCYTE; RECEPTOR
Analytical chemistry
Analytisk kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy