Utilisation of a Pd-MOS sensor for on-line monitoring of dissolved hydrogen in anaerobic digestion

Björnsson, Lovisa (author)
Lund University,Lunds universitet,Miljö- och energisystem,Institutionen för teknik och samhälle,Institutioner vid LTH,Lunds Tekniska Högskola,Environmental and Energy Systems Studies,Department of Technology and Society,Departments at LTH,Faculty of Engineering, LTH
Hörnsten, Gunnar (author)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Mattiasson, Bo (author)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2001
2001
English.
In: Biotechnology and Bioengineering. - 1097-0290. ; 73:1, s. 35-43
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The use of a hydrogen-sensitive palladium-metal oxide semiconductor (Pd-MOS) sensor in combination with a membrane for liquid-to-gas transfer for the detection of dissolved hydrogen was investigated. The system was evaluated with known concentrations of dissolved hydrogen in water. The lowest concentration detected with this set-up was 160 nM. The method was applied to monitoring of a laboratory-scale anaerobic digestion process employing mixed sludge containing mainly food/industrial waste. Pulse loads of glucose were added to the system at different levels of microbial activity, and the microbial status of the culture was reflected in the dissolved hydrogen response. Simultaneous headspace hydrogen measurements were performed, and at the lower levels of dissolved hydrogen no corresponding headspace hydrogen could be detected. When glucose was added to a resting culture the dissolved hydrogen response was rapid and the first response could be detected 9 min after addition of glucose, whereas headspace hydrogen concentrations increased only after 80 to 110 min. This indicates limitations in the liquid-to-gas hydrogen transfer and illustrates the importance of hydrogen monitoring in the liquid. The sensor system developed is flexible, the membrane is easily replaceable, and the probe for liquid-to-gas hydrogen transfer can be adjusted easily to large-scale applications.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Keyword

palladium-metal oxide semiconductor (Pd-MOS) sensor
dissolved hydrogen
on-line
anaerobic digestion
biogas

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Björnsson, Lovis ...
Hörnsten, Gunnar
Mattiasson, Bo
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Industrial Biote ...
Articles in the publication
Biotechnology an ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view