SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Borga Magnus)
 

Sökning: WFRF:(Borga Magnus) > Reproducibility and...

Reproducibility and repeatability of MRI-based body composition analysis

Borga, Magnus (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,AMRA Med AB, Linkoping, Sweden
Ahlgren, Andre (författare)
AMRA Med AB, Linkoping, Sweden
Romu, Thobias (författare)
AMRA Med AB, Linkoping, Sweden
visa fler...
Widholm, Per (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping,AMRA Med AB, Linkoping, Sweden
Dahlqvist Leinhard, Olof, 1978- (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,AMRA Med AB, Linkoping, Sweden
West, Janne (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,AMRA Med AB, Linkoping, Sweden
visa färre...
 (creator_code:org_t)
2020-06-10
2020
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : WILEY. - 0740-3194 .- 1522-2594. ; 84:6, s. 3146-3156
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose There is an absence of reproducibility studies on MRI-based body composition analysis in current literature. Therefore, the aim of this study was to investigate the between-scanner reproducibility and the repeatability of a method for MRI-based body composition analysis. Methods Eighteen healthy volunteers of varying body mass index and adiposity were each scanned twice on five different 1.5T and 3T scanners from three different vendors. Two-point Dixon neck-to knee images and two additional liver scans were acquired with similar protocols. Visceral adipose tissue (VAT) volume, abdominal subcutaneous adipose tissue (ASAT) volume, thigh muscle volume, and muscle fat infiltration (MFI) in the thigh muscle were measured. Liver proton density fat fraction (PDFF) was assessed using two different methods, the scanner vendors 6-point method and an in-house 2-point method. Within-scanner test-retest repeatability and between-scanner reproducibility were calculated using analysis of variance. Results Repeatability coefficients were 13 centiliters (cl) (VAT), 24 cl (ASAT), 17 cl (total thigh muscle volume), 0.53% (MFI), and 1.27-1.37% for liver PDFF. Reproducibility coefficients were 24 cl (VAT), 42 cl (ASAT), 31 cl (total thigh muscle volume), 1.44% (MFI), and 2.37-2.40% for liver PDFF. Conclusion For all measures except MFI, the within-scanner repeatability explained much of the overall reproducibility. The two methods for measuring liver fat had similar reproducibility. This study showed that the investigated method eliminates effects due to scanner differences. The results can be used for power calculations in clinical studies or to better understand the scanner-induced variability in clinical applications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

body composition analysis; chemical shift encoded MRI; fat fraction; MRI; repeatability; reproducibility; water-fat imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy