SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-136141"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-136141" > Postoperative Monit...

Postoperative Monitoring of Free Flaps in Autologous Breast Reconstruction : A Multicenter Comparison of 398 Flaps Using Clinical Monitoring, Microdialysis, and the Implantable Doppler Probe

Whitaker, Iain S. (författare)
Uppsala universitet,Plastikkirurgi
Rozen, Warren M. (författare)
Chubb, Daniel (författare)
Uppsala universitet,Plastikkirurgi
visa fler...
Acosta, Rafael (författare)
Uppsala universitet,Plastikkirurgi
Kiil, Birgitte J. (författare)
Birke-Sorensen, Hanne (författare)
Grinsell, Damien (författare)
Uppsala universitet,Plastikkirurgi
Ashton, Mark W. (författare)
visa färre...
 (creator_code:org_t)
2010-03-10
2010
Engelska.
Ingår i: Journal of reconstructive microsurgery. - : Georg Thieme Verlag KG. - 0743-684X .- 1098-8947. ; 26:6, s. 409-416
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Many techniques for flap monitoring following free tissue transfer have been described; however, there is little evidence that any of these techniques allow for greater rates of flap salvage over clinical monitoring alone. We sought to compare three established monitoring techniques across three experienced microsurgical centers in a comparable cohort of patients. A retrospective, matched cohort study of 398 consecutive free flaps in 347 patients undergoing autologous breast reconstruction was undertaken across three institutions during the same 3-year period, with a single form of postoperative monitoring used at each institution: clinical monitoring alone, the Cook-Swartz implantable Doppler probe, or microdialysis. Both objective and subjective measures of efficacy were assessed. Clinical monitoring alone, the implantable Doppler probe, and microdialysis showed statistically similar rates of flap salvage. False-negative rates were also statistically similar (only seen in the clinically monitored group). However, there was a statistically significant increase in false-positive alarms causing needless take-backs to theater in the microdialysis and implantable Doppler arms, p < 0.001. This study did not find any technique superior to clinical monitoring alone. New monitoring technologies should be compared objectively with clinical monitoring as the current standard in postoperative flap monitoring.

Nyckelord

Breast reconstruction
deep inferior epigastric artery
DIEP flap
perforator flap
superficial inferior epigastric artery perforator flap
Cook probe
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy