Reduced EEG montage has a high accuracy in the post cardiac arrest setting
-
- Backman, Sofia (författare)
- Lund University,Lunds universitet,Klinisk neurofysiologi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Neurophysiology,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
- Cronberg, Tobias (författare)
- Lund University,Lunds universitet,Neurologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Rosén, Ingmar (författare)
- Lund University,Lunds universitet,Klinisk neurofysiologi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Neurophysiology,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
visa fler...
-
- Westhall, Erik (författare)
- Lund University,Lunds universitet,Klinisk neurofysiologi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Neurophysiology,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2020
- 2020
- Engelska 8 s.
-
Ingår i: Clinical Neurophysiology. - : Elsevier BV. - 1388-2457. ; 131:9, s. 2216-2223
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: To study if comatose cardiac arrest patients can be assessed with a reduced number of EEG electrodes. Methods: 110 routine EEGs from 67 consecutive patients, including both hypothermic and normothermic EEGs were retrospectively assessed by three blinded EEG-experts using two different electrode montages. A standard 19-electrode-montage was compared to the reduced version of the same EEGs, down-sampled to six electrodes (F3, T3, P3, F4, T4, P4). We used intra-rater and inter-observer statistics to assess the reliability of the reduced montage for background features and discharges. Results: The reduced montage had almost perfect performance for background continuity (κ 0.80–0.88), including identification of highly malignant backgrounds (burst-suppression/suppression) (κ 0.85–0.94) and benign backgrounds (continuous/nearly continuous) (κ 0.85–0.91). We found substantial performance for identifying rhythmic/periodic discharges (κ 0.79–0.86). The reduced montage had high accuracy for assessment of both highly malignant (sensitivity 91–95%, specificity 94–99%) and benign (sensitivity 89–98%, specificity 91–96%) backgrounds, and periodic/rhythmic patterns (sensitivity 79–100%, specificity 89–99%), compared to the full montage. The inter-observer variability was not increased by the reduced montage. Conclusion: Reduced EEG had high performance for classifying important background and discharge patterns in this post cardiac arrest cohort. Significance: Our results support the use of reduced EEG-montage for monitoring comatose cardiac arrest patients.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
Nyckelord
- Cardiac arrest
- Coma
- EEG monitoring
- Montage
- Postanoxic encephalopathy