SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Extended search

WFRF:(Eastwood Glenn M.)
 

Search: WFRF:(Eastwood Glenn M.) > Near-infrared spect...

Near-infrared spectroscopy of the thenar eminence : comparison of dynamic testing protocols

Lipcsey, Miklos (author)
Uppsala universitet,Anestesiologi och intensivvård
Eastwood, Glenn M. (author)
Woinarski, Nicholas C. Z. (author)
show more...
Bellomo, Rinaldo (author)
show less...
 (creator_code:org_t)
2012
2012
English.
In: Critical Care and Resuscitation. - 1441-2772. ; 14:2, s. 142-147
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Near-infrared spectroscopy of the thenar eminence (NIRSth) is a non-invasive bedside method for assessing tissue oxygenation. The vascular occlusion test (VOT) with a pressure cuff can be used to provide a dynamic assessment of the tissue oxygenation response to ischaemia. VOT has been applied to assess the microcirculation by NIRSth in critically ill patients. The optimal mode of performing such VOT, however, remains controversial. Design, participants and setting: Prospective observational study among a cohort of 11 healthy volunteers in a tertiary intensive care department. Intervention: Measurement of NIRS-derived parameters using 1-, 2- and 3-minute VOTs or VOT to 40% tissue oxygen saturation (StO(2)). Main outcome measure: Changes in StO(2) and tissue haemoglobin index (THI) over time, and relative change from baseline for StO(2) and THI. Results: Mean baseline StO(2) was 80% (SD, 5%) and mean THI was 13.7 (SD, 1.9). The lowest StO(2) at the end of the VOT was 39% (SD, 13%) and 39% (SD, 2%) in the 3-minute and the 40% StO(2) VOTs, respectively. The duration of the 40% StO(2) VOT ranged from 1:35 to 8:21 minutes (median, 3:29 min). There was a difference between the StO(2) curves for the 3-minute and 40% StO(2) VOT (P = 0.005) but not the THI curves. Reported pain score was a median of 3.5 (IQR, 2.5-5.5) and 4 (IQR 2-4) for the 3-minute and 40% StO(2) VOTs, respectively. Conclusions: The 3-minute VOT and the 40% StO(2) appear equivalent. However, the 3-minute VOT carries a degree of decreased patient discomfort and shorter overall duration of execution.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view