SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:oru-82326"
 

Sökning: onr:"swepub:oai:DiVA.org:oru-82326" > Stable refraction a...

Stable refraction and visual acuity in diabetic patients with variable glucose levels under routine care

Agardh, Elisabet (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
Hellgren, Karl-Johan, 1971- (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
Bengtsson, Boel (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
 (creator_code:org_t)
2011-02-23
2011
Engelska.
Ingår i: Acta Ophthalmologica. - : Wiley-Blackwell. - 1755-375X .- 1755-3768. ; 89:2, s. 107-110
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To investigate how refraction and visual acuity may vary in patients with diabetes under routine care.METHODS: Fifty-three eyes of 53 patients with various degrees of diabetic retinopathy were examined prospectively on four different occasions within a month. Refraction, best-corrected visual acuity (expressed as logMAR score) and blood glucose were measured on each occasion. Intraindividual variability was calculated as the range between the highest and lowest measurements. Associations between blood glucose levels and each of the other variables were tested by linear regression analysis for each patient.RESULTS: Refraction was completely stable in 43 patients and changed only slightly in 10, in whom the mean intraindividual variability of the spherical equivalent was 0.4 dioptres. Visual acuity test results were also highly reproducible. Mean intraindividual variability in visual acuity was 0.08 logMAR. Mean haemoglobin A1c (HbA1c) was 7.3 ± 1.5% but individual blood glucose levels ranged from 2.8 to > 22.2 mmol/l. Intraindividual variability ranged from 0.5 to 18.1 mmol/l, with a median of 6.0 mmol/l for the entire group. There were no associations between refraction or visual acuity and blood glucose levels or inter- or intraindividual glucose variations.CONCLUSION: Refraction and visual acuity test results were highly reproducible and stable in patients with reasonably well controlled diabetes but variable blood glucose levels under routine care.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Blood glucose
diabetes
refraction
visual acuity

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Agardh, Elisabet
Hellgren, Karl-J ...
Bengtsson, Boel
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
Acta Ophthalmolo ...
Av lärosätet
Örebro universitet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy