Sökning: WFRF:(Jonson Björn) >
Dynamic elastic pre...
Dynamic elastic pressure-volume loops in healthy pigs recorded with inspiratory and expiratory sinusoidal flow modulationRelationship to static pressure-volume loops.
-
- Bitzén, Ulrika (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Drefeldt, Björn (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Niklason, Lisbet (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Jonson, Björn (författare)
- Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 2004-02-13
- 2004
- Engelska.
-
Ingår i: Intensive Care Medicine. - : Springer Science and Business Media LLC. - 0342-4642 .- 1432-1238. ; 30:3, s. 481-488
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: The objective was to analyse relationships between inspiratory and expiratory static and dynamic elastic pressure-volume (P-el/V) curves in healthy pigs. Design: The modulated low flow method was developed to allow studies also of the expiratory P-el/V curves. Static P-el/V (P-el,P-st/V) and dynamic P-el/V (P-el,P-dyn/V) loops were studied in healthy pigs. Setting: Animal research laboratory in a university hospital. Material: Ten healthy anaesthetised and paralysed pigs. Interventions and measurements: A computer controlled a Servo Ventilator 900C with respect to respiratory rate, inspiratory flow and expiratory pressure to achieve a sinusoidal modulation of inspiration and expiration for determination of P-el,P-dyn/V loops from zero end-expiratory pressure (ZEEP) and from a positive end-expiratory pressure (PEEP) of 6 cmH(2)O to 20, 35 and 50 cmH(2)O. The same system was used for studies of P-el,P-st/V loops with the flow-interruption method from ZEEP and PEEP to 35 cmH(2)O. Recordings were analysed with an iterative technique. Results: The feasibility of automated determination of P-el,P-dyn/V loops was demonstrated. Differences between P-el,P-dyn/V and P-el,P-st/V loops were explained by viscoelastic behaviour. P-el,P-st/V loops recorded from PEEP to 35 cmH(2)O showed no significant hysteresis, indicating a non-significant surface tension hysteresis. P-el,P-dyn/V loops from PEEP and both P-el,P-st/V and P-el,P-dyn/V loops from ZEEP to 35 cmH(2)O showed hysteresis. This indicates that lung collapse/re-expansion caused P-el/V loop hysteresis which, in P-el,P-dyn/V loops, was augmented by viscoelastic behaviour. Conclusions: Viscoelasticity influences P-el,P-dyn/V curves. Hysteresis caused by surface tension merits re-evaluation. Lung collapse and re-expansion may be indicated by hysteresis of P-el/V loops.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
Nyckelord
- mechanical
- respiratory mechanics
- hysteresis
- compliance
- ventilation
- swine
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas