SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Luciano Michelle)
 

Sökning: WFRF:(Luciano Michelle) > Reliability of puls...

Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression

Messina, Antonio (författare)
IRCCS Humanitas Res Hosp, Italy; Humanitas Univ, Italy
Caporale, Mariagiovanna (författare)
Univ Cattolica Sacro Cuore, Italy
Calabro, Lorenzo (författare)
IRCCS Humanitas Res Hosp, Italy; Humanitas Univ, Italy
visa fler...
Lionetti, Giulia (författare)
IRCCS Humanitas Res Hosp, Italy; Humanitas Univ, Italy
Bono, Daniele (författare)
IRCCS Humanitas Res Hosp, Italy; Humanitas Univ, Italy
Matronola, Guia Margherita (författare)
Humanitas Univ, Italy
Brunati, Andrea (författare)
Humanitas Univ, Italy
Frassanito, Luciano (författare)
Univ Cattolica Sacro Cuore, Italy
Morenghi, Emanuela (författare)
IRCCS Humanitas Res Hosp, Italy; Humanitas Univ, Italy
Antonelli, Massimo (författare)
Univ Cattolica Sacro Cuore, Italy
Chew, Michelle (författare)
Linköpings universitet,Avdelningen för klinisk kemi och farmakologi,Medicinska fakulteten,Region Östergötland, ANOPIVA US
Cecconi, Maurizio (författare)
IRCCS Humanitas Res Hosp, Italy; Humanitas Univ, Italy
visa färre...
 (creator_code:org_t)
BMC, 2023
2023
Engelska.
Ingår i: Critical Care. - : BMC. - 1364-8535 .- 1466-609X. ; 27:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BackgroundPulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia.MethodsSystematic review and metanalysis of PPV and SVV use in surgical adult patients. The QUADAS-2 scale was used to assess the risk of bias of included studies. We adopted a metanalysis pooling of aggregate data from 5 subgroups of studies with random effects models using the common-effect inverse variance model. The area under the curve (AUC) of pooled receiving operating characteristics (ROC) curves was reported. A metaregression was performed using FC type, volume, and rate as independent variables.ResultsWe selected 59 studies enrolling 2,947 patients, with a median of fluid responders of 55% (46-63). The pooled AUC for the PPV was 0.77 (0.73-0.80), with a mean threshold of 10.8 (10.6-11.0). The pooled AUC for the SVV was 0.76 (0.72-0.80), with a mean threshold of 12.1 (11.6-12.7); 19 studies (32.2%) reported the grey zone of PPV or SVV, with a median of 56% (40-62) and 57% (46-83) of patients included, respectively. In the different subgroups, the AUC and the best thresholds ranged from 0.69 and 0.81 and from 6.9 to 11.5% for the PPV, and from 0.73 to 0.79 and 9.9 to 10.8% for the SVV. A high Vt and the choice of colloids positively impacted on PPV performance, especially among patients with closed chest and abdomen, or in prone position.ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Pulse pressure variation; Stroke volume variation; Fluid responsiveness; Fluid therapy; Hemodynamic monitoring

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy