SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-21206"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-21206" > Standardized evalua...

Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms

Schaap, M. (författare)
Biomedical Imaging Group Rotterdam, The Netherlands
Metz, C.T. (författare)
Biomedical Imaging Group Rotterdam, The Netherlands,Universidad Politécnica de Madrid, Spain
van Walsum, T. (författare)
Biomedical Imaging Group Rotterdam, The Netherlands
visa fler...
van der Giessen, A.G. (författare)
Biomedical Imaging Group Rotterdam, The Netherlands
Weustink, A.C. (författare)
Erasmus MC, Rotterdam, The Netherlands
Mollet, N.R. (författare)
Erasmus MC, Rotterdam, The Netherlands
Bauer, C. (författare)
Graz University of Technology, Austria
Bogunovic, H. (författare)
Center for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), Barcelona, Spain
Castro, C. (författare)
Universidad Politécnica de Madrid, Spain,MeVis Research, Bremen, Germany
Deng, X. (författare)
Siemens Corporate Research, Princeton, NJ, USA
Dikici, E. (författare)
University of Florida College of Medicine, Jacksonville, FL, USA
O'Donnell, T. (författare)
Siemens Corporate Research, Princeton, NJ, USA
Frenay, M. (författare)
Leiden University Medical Center, The Netherlands
Friman, O. (författare)
MeVis Research, Bremen, Germany
Hoyos, M.H. (författare)
Universidad de los Andes, Bogota, Colombia
Kitslaar, P.H. (författare)
Leiden University Medical Center, The Netherlands
Krissian, K. (författare)
University of Las Palmas of Gran Canaria, Spain,Childrens Hospital Boston, MA, USA
Kuhnel, C. (författare)
MeVis Research, Bremen, Germany
Luengo-Oroz, M.A. (författare)
Universidad Politécnica de Madrid, Spain
Orkisz, M. (författare)
Université de Lyon, France
Smedby, Örjan (författare)
Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping
Styner, M. (författare)
University of North Carolina, Chapel Hill, NC, USA
Szymczak, A. (författare)
Colorado School of Mines, Golden, CO, USA
Tek, H. (författare)
Siemens Corporate Research, Princeton, NJ, USA
Wang, Chunliang (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Linköping Univ., Linköping, Sweden
Warfield, S.K. (författare)
Childrens Hospital Boston, MA, USA
Zambal, S. (författare)
VRVis Research Center for Virtual Reality and Visualization, Vienna, Austria
Zhang, Y. (författare)
The Methodist Hospital Research Institute, Houston, TX, USA
Krestin, G.P. (författare)
Erasmus MC, Rotterdam, The Netherlands
Niessen, W.J. (författare)
Erasmus MC, Rotterdam, The Netherlands
visa färre...
 (creator_code:org_t)
Elsevier, 2009
2009
Engelska.
Ingår i: Medical Image Analysis. - : Elsevier. - 1361-8415 .- 1361-8423. ; 13:5, s. 701-714
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available, and (4) 13 coronary artery centerline extraction algorithms, implemented by different research groups, are quantitatively evaluated and compared. The presented evaluation framework is made available to the medical imaging community for benchmarking existing or newly developed coronary centerline extraction algorithms.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Centerline extraction; Computed tomography; Coronaries; Standardized evaluation; Tracking
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy