On the Frisch–Grid signal in ionization chambers
-
- Al-Adili, Ali (författare)
- Uppsala universitet,Tillämpad kärnfysik
-
- Hambsch, Franz-Josef (författare)
- IRMM JRC EC
-
- Bencardino, Raffaele (författare)
- IRMM JRC EC
-
visa fler...
-
- Pomp, Stephan (författare)
- Uppsala universitet,Tillämpad kärnfysik
-
- Oberstedt, Stephan (författare)
- IRMM JRC EC
-
- Zeynalov, Shakir (författare)
- JINR
-
visa färre...
-
(creator_code:org_t)
- Elsevier, 2012
- 2012
- Engelska.
-
Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 671, s. 103-107
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A recent theoretical approach concerning the grid-inefficiency (GI) problem in Twin Frisch–Grid Ionization Chambers was validated experimentally. The experimental verification focused on the induced signal on the anode plate. In this work the investigation was extended by studying the grid signal. The aim was to verify the grid-signal dependency on the grid inefficiency σ. The measurements were made with fission fragments from 252Cf(sf), using two different grids, with 1 and 2 mm wire distances, leading to the GI values: σ=0.031 and σ=0.083, respectively. The theoretical grid signal was confirmed because the detected grid pulse-height distribution was smaller for the larger σ. By applying the additive GI correction approach, the two grid pulse heights were consistent. In the second part of the work, the corrected grid signal was used to deduce emission angles of the fission fragments. It is inconvenient to treat the grid signal by means of conventional analogue electronics, because of its bipolarity. Therefore, the anode and grid signals were summed to create a unipolar, angle-dependent pulse height. Until now the so-called summing method has been the well-established approach to deduce the angle from the grid signal. However, this operation relies strongly on an accurate and stable calibration between the two summed signals. By application of digital-signal processing, the grid signal's bipolarity is no longer an issue. Hence one can bypass the intermediate summation step of the two different pre-amplifier signals, which leads to higher stability. In this work the grid approach was compared to the summing method in three cases: 252Cf(sf), 235U(n,f) and 234U(n,f). By using the grid directly, the angular resolution was found equally good in the first case but gave 7% and 20% improvements, respectively, in the latter cases.
Nyckelord
- Grid inefficiency
- Ionization chambers
- Summing method
- Physics
- Fysik
- Nuclear Physics
- Kärnfysik