SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-200369"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-200369" > Cross-vendor multip...

Cross-vendor multiparametric mapping of the human brain using 3D-QALAS: A multicenter and multivendor study

Fujita, Shohei (författare)
Juntendo Univ, Japan; Univ Tokyo, Japan; Athinoula A Martinos Ctr Biomed Imaging, MA USA; Harvard Med Sch, MA USA
Gagoski, Borjan (författare)
Harvard Med Sch, MA USA; Boston Childrens Hosp, MA USA
Hwang, Ken-Pin (författare)
MD Anderson Canc Ctr, TX USA
visa fler...
Hagiwara, Akifumi (författare)
Juntendo Univ, Japan
Warntjes, Marcel Jan Bertus (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,SyntheticMR, Linkoping, Sweden
Fukunaga, Issei (författare)
Juntendo Univ, Japan
Uchida, Wataru (författare)
Juntendo Univ, Japan
Saito, Yuya (författare)
Juntendo Univ, Japan
Sekine, Towa (författare)
Juntendo Univ, Japan
Tachibana, Rina (författare)
Juntendo Univ, Japan
Muroi, Tomoya (författare)
Juntendo Univ, Japan
Akatsu, Toshiya (författare)
Juntendo Univ, Japan
Kasahara, Akihiro (författare)
Univ Tokyo, Japan
Sato, Ryo (författare)
Univ Tokyo, Japan
Ueyama, Tsuyoshi (författare)
Univ Tokyo, Japan
Andica, Christina (författare)
Juntendo Univ, Japan; Juntendo Univ, Japan
Kamagata, Koji (författare)
Juntendo Univ, Japan
Amemiya, Shiori (författare)
Univ Tokyo, Japan
Takao, Hidemasa (författare)
Univ Tokyo, Japan
Hoshino, Yasunobu (författare)
Juntendo Univ, Japan
Tomizawa, Yuji (författare)
Juntendo Univ, Japan
Yokoyama, Kazumasa (författare)
Juntendo Univ, Japan
Bilgic, Berkin (författare)
Athinoula A Martinos Ctr Biomed Imaging, MA USA; Harvard Med Sch, MA USA; Harvard MIT Hlth Sci & Technol, MA USA
Hattori, Nobutaka (författare)
Juntendo Univ, Japan
Abe, Osamu (författare)
Univ Tokyo, Japan
Aoki, Shigeki (författare)
Juntendo Univ, Japan
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : WILEY. - 0740-3194 .- 1522-2594.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To evaluate a vendor-agnostic multiparametric mapping scheme based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) for whole-brain T1, T2, and proton density (PD) mapping.Methods: This prospective, multi-institutional study was conducted between September 2021 and February 2022 using five different 3T systems from four prominent MRI vendors. The accuracy of this technique was evaluated using a standardized MRI system phantom. Intra-scanner repeatability and inter-vendor reproducibility of T1, T2, and PD values were evaluated in 10 healthy volunteers (6 men; mean age +/- SD, 28.0 +/- 5.6 y) who underwent scan-rescan sessions on each scanner (total scans = 100). To evaluate the feasibility of 3D-QALAS, nine patients with multiple sclerosis (nine women; mean age +/- SD, 48.2 +/- 11.5 y) underwent imaging examination on two 3T MRI systems from different manufacturers.Results: Quantitative maps obtained with 3D-QALAS showed high linearity (R2 = 0.998 and 0.998 for T1 and T2, respectively) with respect to reference measurements. The mean intra-scanner coefficients of variation for each scanner and structure ranged from 0.4% to 2.6%. The mean structure-wise test-retest repeatabilities were 1.6%, 1.1%, and 0.7% for T1, T2, and PD, respectively. Overall, high inter-vendor reproducibility was observed for all parameter maps and all structure measurements, including white matter lesions in patients with multiple sclerosis.Conclusion: The vendor-agnostic multiparametric mapping technique 3D-QALAS provided reproducible measurements of T1, T2, and PD for human tissues within a typical physiological range using 3T scanners from four different MRI manufacturers.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

cross-vendor technique; data pooling; multiparametric mapping; quantitative magnetic resonance imaging; relaxation time; relaxometry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy