SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:88d43823-4d4c-4e2e-a23d-d854397ab228"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:88d43823-4d4c-4e2e-a23d-d854397ab228" > Accuracy of 1-Hour ...

Accuracy of 1-Hour Plasma Glucose During the Oral Glucose Tolerance Test in Diagnosis of Type 2 Diabetes in Adults : A Meta-analysis

Ahuja, Vasudha (författare)
Institute for Molecular Medicine Finland (FIMM),University of Helsinki
Aronen, Pasi (författare)
Helsinki University Central Hospital,University of Helsinki
Pramodkumar, T. A. (författare)
Madras Diabetes Research Foundation
visa fler...
Looker, Helen (författare)
National Institute of Diabetes and Digestive and Kidney Diseases, Phoenix
Chetrit, Angela (författare)
Gertner Institute for Epidemiology and Health Policy Research
Bloigu, Aini H. (författare)
University of Oulu
Juutilainen, Auni (författare)
University of Eastern Finland
Bianchi, Cristina (författare)
University Hospital of Pisa
La Sala, Lucia (författare)
IRCCS Multimedica
Anjana, Ranjit Mohan (författare)
Madras Diabetes Research Foundation
Pradeepa, Rajendra (författare)
Madras Diabetes Research Foundation
Venkatesan, Ulagamadesan (författare)
Madras Diabetes Research Foundation
Jebarani, Sarvanan (författare)
Madras Diabetes Research Foundation
Baskar, Viswanathan (författare)
Madras Diabetes Research Foundation
Fiorentino, Teresa Vanessa (författare)
University Magna Graecia
Timpel, Patrick (författare)
Dresden University of Technology
DeFronzo, Ralph A. (författare)
University of Texas Health Science Centre
Ceriello, Antonio (författare)
IRCCS Multimedica
Del Prato, Stefano (författare)
University Hospital of Pisa
Abdul-Ghani, Muhammad (författare)
University of Texas Health Science Centre
Keinänen-Kiukaanniemi, Sirkka (författare)
University of Oulu
Dankner, Rachel (författare)
Gertner Institute for Epidemiology and Health Policy Research,Tel-Aviv University
Bennett, Peter H. (författare)
National Institute of Diabetes and Digestive and Kidney Diseases, Phoenix
Knowler, William C. (författare)
National Institute of Diabetes and Digestive and Kidney Diseases, Phoenix
Schwarz, Peter (författare)
German Center for Diabetes Research,Dresden University of Technology,University Clinic Carl Gustav Carus at the TU Dresden
Sesti, Giorgio (författare)
Sapienza University of Rome
Oka, Rie (författare)
Hokuriku Central Hospital
Mohan, Viswanathan (författare)
Madras Diabetes Research Foundation
Groop, Leif (författare)
Lund University,Lunds universitet,Translationell Muskel Forskning,Forskargrupper vid Lunds universitet,Translational Muscle Research,Lund University Research Groups,University of Helsinki,Institute for Molecular Medicine Finland (FIMM)
Tuomilehto, Jaakko (författare)
Finnish National Institute for Health and Welfare,University of Helsinki,King Abdulaziz University
Ripatti, Samuli (författare)
Broad Institute,Institute for Molecular Medicine Finland (FIMM),University of Helsinki
Bergman, Michael (författare)
New York University
Tuomi, Tiinamaija (författare)
Lund University,Lunds universitet,Diabetiska komplikationer,Forskargrupper vid Lunds universitet,Diabetic Complications,Lund University Research Groups,Institute for Molecular Medicine Finland (FIMM),Helsinki University Central Hospital,Folkhälsan Research Center,University of Helsinki
visa färre...
 (creator_code:org_t)
2021-03-15
2021
Engelska 8 s.
Ingår i: Diabetes Care. - : American Diabetes Association. - 1935-5548 .- 0149-5992. ; 44:4, s. 1062-1069
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: One-hour plasma glucose (1-h PG) during the oral glucose tolerance test (OGTT) is an accurate predictor of type 2 diabetes. We performed a meta-analysis to determine the optimum cutoff of 1-h PG for detection of type 2 diabetes using 2-h PG as the gold standard. RESEARCH DESIGN AND METHODS: We included 15 studies with 35,551 participants from multiple ethnic groups (53.8% Caucasian) and 2,705 newly detected cases of diabetes based on 2-h PG during OGTT. We excluded cases identified only by elevated fasting plasma glucose and/or HbA1c. We determined the optimal 1-h PG threshold and its accuracy at this cutoff for detection of diabetes (2-h PG ≥11.1 mmol/L) using a mixed linear effects regression model with different weights to sensitivity/specificity (2/3, 1/2, and 1/3). RESULTS: Three cutoffs of 1-h PG, at 10.6 mmol/L, 11.6 mmol/L, and 12.5 mmol/L, had sensitivities of 0.95, 0.92, and 0.87 and specificities of 0.86, 0.91, and 0.94 at weights 2/3, 1/2, and 1/3, respectively. The cutoff of 11.6 mmol/L (95% CI 10.6, 12.6) had a sensitivity of 0.92 (0.87, 0.95), specificity of 0.91 (0.88, 0.93), area under the curve 0.939 (95% confidence region for sensitivity at a given specificity: 0.904, 0.946), and a positive predictive value of 45%. CONCLUSIONS: The 1-h PG of ≥11.6 mmol/L during OGTT has a good sensitivity and specificity for detecting type 2 diabetes. Prescreening with a diabetes-specific risk calculator to identify high-risk individuals is suggested to decrease the proportion of false-positive cases. Studies including other ethnic groups and assessing complication risk are warranted.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Publikations- och innehållstyp

for (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy