The role of functional parameters for topographical characterization of bone-anchored implants

Arvidsson, Anna, 1973 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Sater, Bashar (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Wennerberg, Ann, 1955 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
 (creator_code:org_t)
2006
2006
Engelska.
Ingår i: Clin Implant Dent Relat Res. ; 8:2, s. 70-6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: The surface topographical characterization of bone-anchored implants has been recommended to be based on amplitude, spatial, and hybrid parameters. There are also functional parameters that have the potential to describe characteristics important for a specific application. PURPOSE: The aim of the present study was to evaluate if parameters that have been described as functional in engineering applications are also relevant in the topographical characterization of bone-anchored implants. MATERIALS AND METHODS: The surface topography of threaded titanium implants with different surface roughness (S(a), S(ds), and S(dr)) was analyzed with an optical interferometer, and five candidating functional parameters (S(bi), S(ci), S(vi), S(m), and S(c)) were calculated. Examples of the same parameters for five commercially available dental implants were also calculated. Results The highest core fluid retention index (S(ci)) was displayed by the turned implants, followed by fixtures blasted with 250- and 25-microm particles, respectively. Fixtures blasted with 75-microm Al(2)O(3) particles displayed the lowest S(ci) value. This is the inverse order of the bone biological ranking based on earlier in vivo studies with the experimental surfaces included in the present study. CONCLUSION: A low core fluid retention index (S(ci)) seems favorable for bone-anchored implants. Therefore, it is suggested to include S(ci) to the set of topographical parameters for bone-anchored implants to possibly predict the biological outcome.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Air Abrasion
Dental
Aluminum Oxide/chemistry
Biomechanics
*Dental Implants
Dental Materials/chemistry
*Dental Prosthesis Design
Humans
Interferometry
Optics
Particle Size
Surface Properties
Titanium/chemistry
Wettability

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Arvidsson, Anna, ...
Sater, Bashar
Wennerberg, Ann, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy