SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:mau-5025"
 

Sökning: onr:"swepub:oai:DiVA.org:mau-5025" > High-sensitive card...

High-sensitive cardiac Troponin T is superior to echocardiography in predicting 1-year mortality in patients with SIRS and shock in intensive care.

Bergenzaun, Lill (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine,Lund Univ, Sweden
Öhlin, Hans (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund Univ, Sweden
Gudmundsson, Petri (författare)
Malmö högskola,Institutionen för vårdvetenskap (VV),Malmo Univ, Sweden
visa fler...
Düring, Joachim (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Forskargrupper vid Lunds universitet,Anaesthesiology and Intensive Care Medicine,Lund University Research Groups,Lund Univ, Sweden
Willenheimer, Ronnie (författare)
Lund University,Lunds universitet,Kardiologiska klinikens forskargrupp,Forskargrupper vid Lunds universitet,Cardiology Research Group,Lund University Research Groups,Lund Univ, Sweden
Chew, Michelle (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine,Lund Univ, Sweden
visa färre...
 (creator_code:org_t)
2012-09-24
2012
Engelska.
Ingår i: BMC Anesthesiology. - : BioMed Central. - 1471-2253 .- 1471-2253. ; 12:25
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Left ventricular (LV) dysfunction is well documented in the critically ill. We assessed 1-year mortality in relation to cardiac biomarkers and LV function parameters by echocardiography in patients with shock. METHODS: A prospective, observational, cohort study of 49 patients. B-natriuretic peptide (BNP), highsensitive troponin T (hsTNT) and transthoracic echocardiography (TTE) were assessed within 12 h of study inclusion. LV systolic function was measured by ejection fraction (LVEF), mean atrioventricular plane displacement (AVPDm), peak systolic tissue Doppler velocity imaging (TDIs) and velocity time integral in the LV outflow tract (LVOT VTI). LV diastolic function was evaluated by transmitral pulsed Doppler (E, A, E/A, E-deceleration time), tissue Doppler indices (e, a, E/e) and left atrial volume (La volume). APACHE II (Acute Physiology and Chronic Health Evaluation) and SOFA (Sequential Organ Failure Assessment) scores were calculated. RESULTS: hsTNT was significantly higher in non-survivors than in survivors (60 [17.0-99.5] vs 168 [89.8-358] ng/l, p = 0.003). Other univariate predictors of mortality were APACHE II (p = 0.009), E/e (p = 0.023), SOFA (p = 0.024) and age (p = 0.031). Survivors and nonsurvivors did not differ regarding BNP (p = 0.26) or any LV systolic function parameter (LVEF p = 0.87, AVPDm p = 0.087, TDIs p = 0.93, LVOT VTI p = 0.18). Multivariable logistic regression analysis identified hsTNT (p = 0.010) as the only independent predictor of 1-year mortality; adjusted odds ratio 2.0 (95% CI 1.2- 3.5). CONCLUSIONS: hsTNT was the only independent predictor of 1-year mortality in patients with shock. Neither BNP nor echocardiographic parameters had an independent prognostic value. Further studies are needed to establish the clinical significance of elevated hsTNT in patients in shock.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Nyckelord

Echocardiography
BNP
High-sensitive TNT
Myocardial function
Mortality
Shock
Echocardiography
BNP
High-sensitive TNT
Myocardial function
Mortality
Shock

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy