SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-167590"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-167590" > Biofeedback neuromu...

Biofeedback neuromuscular electrical stimulation front-end for dysphagia treatment

Hu, R. (författare)
Qin, Yajie (författare)
Tian, Y. (författare)
visa fler...
Hong, Z. (författare)
Yang, Geng (författare)
KTH,Industriell och Medicinsk Elektronik
Zheng, Lirong (författare)
KTH,Industriell och Medicinsk Elektronik,Fudan University, China
Jia, Jie (författare)
5 Department of Rehabilitation, Huashan Hospital, Shanghai, China
Yang, Cuiwei (författare)
Department of Electronics Engineering, Fudan University, Shanghai, China
Wu, X. (författare)
Wang, Y. (författare)
visa färre...
 (creator_code:org_t)
IEEE Press, 2014
2014
Engelska.
Ingår i: IEEE 2014 Biomedical Circuits and Systems Conference, BioCAS 2014 - Proceedings. - : IEEE Press. - 9781479923465 ; , s. 612-615
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • A dedicated front-end for biofeedback neuromuscular electrical stimulation (NESM) system is proposed. For controllable dysphagia treatment, the integrated circuit (IC) provides a stimulator front-end with programmable stimulation parameters (2μA-1mA current amplitude, DC-2KHz frequency, and variable duty cycle) and an electromyogram/impedance (EMG/ETI) readout front-end with programmable gain and bandwidth (42-80dB, 0.1Hz-1.2KHz) for biofeedback. Area-efficient, low-power but high precision current controlling is achieved by inducing the sigma-delta modulator technique in the stimulation channel. The measured impedance and EMG signal are used to determine the stimulation parameters, enabling a closed loop optimized treatment. The proposed front-end is fabricated in a 0.18 μm standard CMOS process technology and dissipates a peak power of 2.3 mW at the supply voltage of 1.8 V. Measurement results on a live person are also provided to validate the system's effectiveness.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

Biofeedback
EMG
Neuromuscular electrical stimulation
CMOS integrated circuits
Delta modulation
Delta sigma modulation
Electromyography
Modulators
Measured impedance
Programmable gain
Programmable stimulation
Sigma Delta modulator
Standard CMOS process
Stimulation parameters

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy