Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Klinisk laboratoriemedicin)
> (2010-2014) >
Calibrators for Cli...
Calibrators for Clinical Measurements of Phosphorylated H2AX in Patient Cells by Flow Cytometry
-
- Muslimovic, Aida (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
-
- Johansson, Pegah, 1978 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
-
- Rüetschi, Ulla, 1962 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
-
visa fler...
-
- Hammarsten, Ola (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
-
visa färre...
-
(creator_code:org_t)
- Bentham Science Publishers Ltd. 2012
- 2012
- Engelska.
-
Ingår i: The Open Clinical Chemistry Journal. - : Bentham Science Publishers Ltd.. - 2588-7785 .- 1874-2416. ; 5:1, s. 33-39
- Relaterad länk:
-
http://benthamopen.c...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.2...
-
visa färre...
Abstract
Ämnesord
Stäng
- Abstract: Agents that induce DNA double-strand breaks (DSBs), such as ionizing radiation, are frequently used in cancer therapy. H2AX is rapidly phosphorylated in response to DSBs and serves as a way to measure the extent of DSBs induced in patient cells. We have previously reported a flow cytometry-based method for measuring H2AX phosphorylation in pa-tient cells undergoing radiotherapy. To be able to implement measurement of H2AX phosphorylation in clinical practice, we have characterized calibrators for the flow cytometry analysis based on phosphopeptide-coated beads and fixed cells. The calibrator beads and fixed cells lost less than 11% of the signal after storage for 40 days under optimal conditions and were able to correct for day-to-day variation in method performance.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Nyckelord
- H2AX
- flow cytometry
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas