Evaluation of Pressure Generated by Resistors From Different Positive Expiratory Pressure Devices

Fagevik Olsén, Monika, 1964 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery,Gothenburg Univ, Dept Gastrosurg Res & Educ, Sahlgrenska Acad, Gothenburg, Sweden.;Gothenburg Univ, Dept Phys Therapy, Sahlgrenska Univ Hosp, Gothenburg, Sweden.;Gothenburg Univ, Sahlgrenska Acad, Gothenburg, Sweden.,Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital,Department of Gastrosurgical Research and Education, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden; Department of Physical Therapy, Sahlgrenska University Hospital and Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden
Carlsson, Maria L., 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation,Gothenburg Univ, Dept Phys Therapy, Sahlgrenska Univ Hosp, Gothenburg, Sweden.;Gothenburg Univ, Sahlgrenska Acad, Gothenburg, Sweden.,Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital,Department of Physical Therapy, Sahlgrenska University Hospital and Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden
Olsén, Erik, 1994 (författare)
Chalmers, S-41296 Gothenburg, Sweden.,Chalmers tekniska högskola,Chalmers University of Technology,Chalmers University of Technology, Gothenburg, Sweden
visa fler...
Westerdahl, Elisabeth (författare)
Uppsala universitet,Klinisk fysiologi,Örebro universitet,Örebro University,Institutionen för hälsovetenskap och medicin,Department of Medical Sciences, Clinical Physiology, Uppsala University, Uppsala, Sweden
visa färre...
 (creator_code:org_t)
2015-05-05
2015
Engelska.
Ingår i: Respiratory Care. - : Daedalus Enterprises. - 0020-1324 .- 1943-3654. ; 60:10, s. 1418-1423
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. METHODS: Resistors from 4 flow-regulated PEP devices (Pep/Rmt system, Wellspect HealthCare; Pipe P breathing exerciser, Koo Medical Equipment; Mini-PEP, Philips Respironics [including resistors by Rusch]; and 15-mm endo-adapter, VBM Medizintechnik) were tested randomly by a blinded tester at constant flows of 10 and 18 L/min from an external gas system. All resistors were tested 3 times. RESULTS: Resistors with a similar diameter produced statistically significant different pressures at the same flow. The differences were smaller when the flow was 10 L/min compared with 18 L/min. The differences were also smaller when the diameter of the resistor was increased. The pressures produced by the 4 resistors of the same size were all significantly different when measuring 1.5- and 2.0-mm resistors at a flow of 10 L/min and 2.0-mm resistors at a flow of 18 L/min (P < .001). There were no significant differences between any of the resistors when testing sizes of 4.5 and 5.0 mm at either flow. The Mini-PEP and adapter resistors gave the highest pressures. CONCLUSIONS: Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures. (C) 2015 Daedalus Enterprises

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Allmänmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- General Practice (hsv//eng)

Nyckelord

positive expiratory pressure
breathing exercises
resistance breathing
chest-wall kinematics
physiotherapy
patterns
disease
bottle
copd
General & Internal Medicine
Respiratory System
positive expiratory pressure
Family Medicine

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy