Full-scale in-line hydrolysis and simulation for potential energy and resource savings in activated sludge – a case study
-
- Hey, Tobias (författare)
- Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Jönsson, Karin (författare)
- Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- la Cour Jansen, Jes (författare)
- Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
(creator_code:org_t)
- Informa UK Limited, 2012
- 2012
- Engelska.
-
Ingår i: Environmental Technology. - : Informa UK Limited. - 1479-487X .- 0959-3330. ; 33:15, s. 1819-1825
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The potential effects of altering primary settlers during biological in-line hydrolysis and converting a nitrifying activated sludge process into a partial pre-denitrification process for the purpose of resource conservation were evaluated. A full-scale primary sludge hydrolysis experiment was performed at a wastewater treatment plant and implemented in a dynamic modelling tool based on ASM2d. The full-scale hydrolysis experiment achieved a volatile fatty acid (VFA) production of 43 g CODHAc·m−3 with no release of ammonium. Additional nitrogen removal of 44 t N·a−1 was simulated, and the produced hydrolysate was able to replace 50% of the annual ethanol usage. Furthermore, 196 MWh of electricity per annum could be saved through the reduction of ethanol production and the optimization of the operation strategy of the activated sludge tank by operating a different number of anoxic zones.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Kemiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Chemical Engineering (hsv//eng)
Nyckelord
- ASM2d
- energy savings
- full scale
- hydrolysis
- internal carbon source