Sökning: onr:"swepub:oai:lup.lub.lu.se:7ac4ece9-d27c-4a85-9912-7561ceadc80f" >
Removal of pharmace...
Removal of pharmaceuticals in WWTP effluents by ozone and hydrogen peroxide
-
- Hey, Gerly (författare)
- Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Vega, S. R. (författare)
-
- Fick, Jerker (författare)
- Umeå universitet,Kemiska institutionen
-
visa fler...
-
- Tysklind, Mats (författare)
- Umeå universitet,Kemiska institutionen
-
Ledin, A. (författare)
-
- la Cour Jansen, Jes (författare)
- Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Andersen, H. R. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2014-01-28
- 2014
- Engelska.
-
Ingår i: Water S.A.. - : Academy of Science of South Africa. - 1816-7950 .- 0378-4738. ; 40:1, s. 165-173
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://www.ajol.inf...
-
https://lup.lub.lu.s...
-
https://doi.org/10.4...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Ozonation to achieve removal of pharmaceuticals from wastewater effluents, with pH values in the upper and lower regions of the typical range for Swedish wastewater, was investigated. The main aim was to study the effects of varying pH values (6.0 and 8.0), and if small additions of H2O2 prior to ozone treatment could improve the removal and lower the reaction time. The effluents studied differed in their chemical characteristics, particularly in terms of alkalinity (65.3-427 mg center dot l(-1) HCO3-), COD (18.2-41.8 mg center dot l(-1)), DOC (6.9-12.5 mg center dot l(-1)), ammonium content (0.02-3.6 mg center dot l(-1)) and specific UV absorbance (1.78-2.76 l center dot mg(-1)center dot m(-1)). As expected, lower ozone decomposition rates were observed in the effluents at pH 6.0 compared to pH 8.0. When pH 8.0 effluents were ozonated, a higher degree of pharmaceutical removal occurred in the effluent with low specific UV absorbance. For pH 6.0 effluents, the removal of pharmaceuticals was most efficient in the effluent with the lowest organic content. The addition of H2O2 had no significant effect on the quantitative removal of pharmaceuticals but enhanced the ozone decomposition rate. Thus, H2O2 addition increased the reaction rate. In practice, this will mean that the reactor volume needed for the ozonation of wastewater effluents can be reduced.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Kemiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Chemical Engineering (hsv//eng)
- NATURVETENSKAP -- Kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences (hsv//eng)
Nyckelord
- ozone
- pharmaceuticals
- hydrogen peroxide
- wastewater effluents
- ozone
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas