Sökning: onr:"swepub:oai:lup.lub.lu.se:efb9c748-10d7-4f55-a43b-ed758fd5c064" >
Required ozone dose...
Required ozone doses for removing pharmaceuticals from wastewater effluents
-
Antoniou, Maria G. (författare)
-
- Hey, Gerly (författare)
- Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Rodriguez Vega, Sergio (författare)
-
visa fler...
-
Spiliotopoulou, Aikaterini (författare)
-
- Fick, Jerker (författare)
- Umeå universitet,Kemiska institutionen
-
- Tysklind, Mats (författare)
- Umeå universitet,Kemiska institutionen
-
- la Cour Jansen, Jes (författare)
- Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Andersen, Henrik Rasmus (författare)
-
visa färre...
-
(creator_code:org_t)
- Amsterdam : Elsevier BV, 2013
- 2013
- Engelska.
-
Ingår i: Science of the Total Environment. - Amsterdam : Elsevier BV. - 1879-1026 .- 0048-9697. ; 456, s. 42-49
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://backend.orbi...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- The aim of the this study was to investigate the ozone dosage required to remove active pharmaceutical ingredients (APIs) from biologically treated wastewater of varying quality, originated from different raw wastewater and wastewater treatment processes. Secondary effluents from six Swedish wastewater treatment plants (WWTP) were spiked with 42 APIs (nominal concentration 1 mu g/L) and treated with different O-3 doses (0.5-12.0 mg/L ozone) in bench-scale experiments. In order to compare the sensitivity of APIs in each matrix, the specific dose of ozone required to achieve reduction by one decade of each investigated API (DDO3) was determined for each effluent by fitting a first order equation to the remaining concentration of API at each applied ozone dose. Ozone dose requirements were found to vary significantly between effluents depending on their matrix characteristics. The specific ozone dose was then normalized to the dissolved organic carbon (DOC) of each effluent. The DDO3/DOC ratios were comparable for each API between the effluents. 15 of the 42 investigated APIs could be classified as easily degradable (DDO3/DOC <= 0.7), while 19 were moderately degradable (0.7 < DDO3/DOC <= 1.4), and 8 were recalcitrant towards O-3-treatment (DDO3/DOC > 1.4). Furthermore, we predict that a reasonable estimate of the ozone dose required to remove any of the investigated APIs may be attained by multiplying the experimental average DDO3/DOC obtained with the actual DOC of any effluent. (C) 2013 Elsevier B.V. All rights reserved.
Ämnesord
- NATURVETENSKAP -- Geovetenskap och miljövetenskap -- Miljövetenskap (hsv//swe)
- NATURAL SCIENCES -- Earth and Related Environmental Sciences -- Environmental Sciences (hsv//eng)
- NATURVETENSKAP -- Kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences (hsv//eng)
Nyckelord
- Matrix effect
- Ozonation
- Ozone dose
- Pharmaceuticals
- Wastewater
- Matrix effect
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas