SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:31329c0e-5c8b-400e-84d1-0bbdac852574"
 

Sökning: onr:"swepub:oai:research.chalmers.se:31329c0e-5c8b-400e-84d1-0bbdac852574" > Elevation angle ali...

Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements

Moseev, D. (författare)
Max Planck Society for the Advancement of Science (MPG), Germany
Meo, F. (författare)
Technical University of Denmark, Denmark
Korsholm, S. B. (författare)
Technical University of Denmark, Denmark
visa fler...
Bindslev, H. (författare)
Aarhus University, Denmark
Furtula, Vedran, 1981 (författare)
Chalmers University of Technology,Chalmers tekniska högskola
Kantor, M. (författare)
Russian Academy of Sciences, Russian Federation,Forschungszentrum Jülich GmbH, Germany
Leipold, F. (författare)
Technical University of Denmark, Denmark
Michelsen, P. K. (författare)
Technical University of Denmark, Denmark
Nielsen, S. K. (författare)
Technical University of Denmark, Denmark
Salewski, M. (författare)
Technical University of Denmark, Denmark
Stejner, M. (författare)
Technical University of Denmark, Denmark
visa färre...
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: Review of Scientific Instruments. - 0034-6748. ; 83:10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Localized measurements of the fast ion velocity distribution function and the plasma composition measurements are of significant interest for the fusion community. Collective Thomson scattering (CTS) diagnostics allow such measurements with spatial and temporal resolution. Localized measurements require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic on TEXTOR without a source of probing radiation in discharges with sawtooth oscillations, an elevation angle misalignment of 0.9 degrees was found with an accuracy of 0.25 degrees.

Nyckelord

radiation
ion temperature

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy