SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:c9b0e8f1-d187-4ac2-ac0e-fc1b2338b6eb"
 

Sökning: onr:"swepub:oai:research.chalmers.se:c9b0e8f1-d187-4ac2-ac0e-fc1b2338b6eb" > Copper Iron Convers...

Copper Iron Conversion Coating for Solid Oxide Fuel Cell Interconnects

Grolig, Jan Gustav, 1986 (författare)
Oorganisk miljökemi,Energi och material,Institutionen för kemi och kemiteknik,Chalmers tekniska högskola,Environmental Inorganic Chemistry,Energy and Material,Department of Chemistry and Chemical Engineering,Chalmers University of Technology
Alnegren, Patrik, 1988 (författare)
Oorganisk miljökemi,Energi och material,Institutionen för kemi och kemiteknik,Chalmers tekniska högskola,Environmental Inorganic Chemistry,Energy and Material,Department of Chemistry and Chemical Engineering,Chalmers University of Technology
Froitzheim, Jan, 1981 (författare)
Oorganisk miljökemi,Energi och material,Institutionen för kemi och kemiteknik,Chalmers tekniska högskola,Environmental Inorganic Chemistry,Energy and Material,Department of Chemistry and Chemical Engineering,Chalmers University of Technology
visa fler...
Svensson, Jan-Erik, 1965 (författare)
Oorganisk miljökemi,Energi och material,Institutionen för kemi och kemiteknik,Chalmers tekniska högskola,Environmental Inorganic Chemistry,Energy and Material,Department of Chemistry and Chemical Engineering,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Journal of Power Sources. - : Elsevier BV. - 0378-7753. ; 297, s. 534-539
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A conversion coating of iron and copper was investigated with the purpose of increasing the performance of Sanergy HT as a potential SOFC interconnect material. Samples were exposed to a simulated cathode atmosphere (air, 3 % H2O) for durations of up to 1000 h at 850 °C. Their performance in terms of corrosion, chromium evaporation and electrical resistance (ASR) was monitored and compared to uncoated and cobalt-coated Sanergy HT samples. The copper iron coating had no negative effects on corrosion protection and decreased chromium evaporation by about 80%. An Area Specific Resistance (ASR) of 10 mΩcm2 was reached after 1000 h of exposure. Scanning Electron Microscopy revealed well adherent oxide layers comprised of an inner chromia layer and an outer spinel oxide layer.

Ämnesord

NATURVETENSKAP  -- Kemi -- Oorganisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Inorganic Chemistry (hsv//eng)

Nyckelord

Metal coatings
Electrical resistances
Evaporation
Solid oxide fuel cells (SOFC)
Corrosion
Chromia layers
Sanergy HT
Chromium volatilization
Conversion coatings
Coatings
Copper
Scanning electron microscopy
Chromium
Interconnect
SOFC
Area-specific resistances
Area specific resistance
Spinel oxide
Sofc interconnect
Fuel cells
Iron

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst. Hantera kakor

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy