SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0018 9499 OR L773:1558 1578 "

Sökning: L773:0018 9499 OR L773:1558 1578

  • Resultat 1-10 av 175
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andreou, Charalambos M., et al. (författare)
  • Single Event Transients and Pulse Quenching Effects in Bandgap Reference Topologies for Space Applications
  • 2016
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 63:6, s. 2950-2961
  • Tidskriftsartikel (refereegranskat)abstract
    • An architectural performance comparison of bandgap voltage reference variants, designed in a 0.18 mu m CMOS process, is performed with respect to single event transients. These are commonly induced in microelectronics in the space radiation environment. Heavy ion tests (Silicon, Krypton, Xenon) are used to explore the analog single-event transients and have revealed pulse quenching mechanisms in analogue circuits. The different topologies are compared, in terms of cross-section, pulse duration and pulse amplitude. The measured results, and the explanations behind the findings, reveal important guidelines for designing analog integrated circuits, which are intended for space applications. The paper includes an analysis on how pulse quenching occurs within the indispensable current mirror, which is used in every analog circuit.
  •  
2.
  • Anelli, A., et al. (författare)
  • Measurement and simulation of the neutron response and detection efficiency of a Pb-scintillating fiber calorimeter
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 55:3, s. 1409-1412
  • Tidskriftsartikel (refereegranskat)abstract
    • We have measured the overall detection efficiency to neutrons of a small prototype of the KLOE Pb-scintillating fiber calorimeter in the kinetic energy range [5,175] MeV. using the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 28% to 33%. This value largely exceeds the estimated similar to 8% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beamline has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented together with first data to Monte Carlo comparison. The results show an overall neutron efficiency of about 35%. The reasons for such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.
  •  
3.
  • Argume, A., et al. (författare)
  • NOAA Image Data Acquisition to Determine Soil Moisture in Arequipa - Perú
  • 2021
  • Ingår i: IEEE Transactions on Nuclear Science. - : IEEE. - 0018-9499 .- 1558-1578. ; 68:8, s. 1933-1936
  • Tidskriftsartikel (refereegranskat)abstract
    • In recent years, irrigations have been built on dry areas in Majes-Arequipa. Over time, the irrigations water forms moist areas in lower areas, which can have positive or negative consequences. Therefore, it is important to know in advance where the water from the new irrigation will appear. The limited availability of real-time satellite image data is still a hindrance to some applications. Data from environmental satellites NOAA (National Oceanic and Atmospheric Administration) are available fee and license free. In order to receive data, users must obtain necessary equipment. In this work we present a satellite data acquisition system with an RTL SDR receiver, two 137-138 Mhz designed antennas, Orbitron, SDRSharp, WXTolmag and MatLab software. We have designed two antennas, a Turnstile Crossed dipole antenna with Balun and a quadrifilar helicoidal antenna. The antennas parameter measurements show very good correspondence with those obtained by simulation. The RTL SDR RTL2832U receiver, combined with our antennas and software, forms the system for recording, decoding, editing and displaying Automatic Picture Transmission (APT) signals. The results show that the satellite image receptions are sufficiently clear and descriptive for further analysis.
  •  
4.
  • Aykac, M., et al. (författare)
  • Timing performance of Hi-Rez detector for time-of-flight (TOF) PET
  • 2006
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 53:3, s. 1084-1089
  • Tidskriftsartikel (refereegranskat)abstract
    • Positron emission tomography (PET)-based on time-of-flight (TOF) is desired to enhance the image quality by improving the noise variance in the reconstruction. This benchtop study evaluates the timing performance of the current Hi-Rez detector which is based on a 13/spl times/13 LSO array of 4 mm/spl times/4 mm/spl times/20 mm crystals and not optimized for TOF PET applications. A Hamamatsu R9779, fast, 51-mm-diameter PMT was used for some experiments in this study as a reference PMT and its time resolution was measured to be 160 ps with a plastic scintillator. The average crystal time resolution of two Hi-Rez detectors, coupled to a 2/spl times/2 array of Hamamatsu 25-mm-diameter R8619 PMTs at +1050 V, in coincidence was measured to be 733 ps. The average crystal energy resolutions for two detectors were measured 13.1% and 13.2%. The average crystal time resolution of two Hi-Rez detectors improved from 733 ps to 642 ps when the PMT voltage was increased to +1300 V. The Hi-Rez detector was originally optimized for good energy resolution to reduce scatter and high packing fraction to obtain high sensitivity and improved spatial resolution for clinical PET.
  •  
5.
  • Badel, Xavier, et al. (författare)
  • Metallized and oxidized silicon macropore arrays filled with a scintillator for CCD-based X-ray imaging detectors
  • 2004
  • Ingår i: IEEE Transactions on Nuclear Science. - : IEEE. - 0018-9499 .- 1558-1578. ; 51:3, s. 1001-1005, s. 1006-1010
  • Tidskriftsartikel (refereegranskat)abstract
    • Silicon charge-coupled devices (CCDs) covered with a scintillating film are now available on the market for use in digital medical imaging. However, these devices could still be improved in terms of sensitivity and especially spatial resolution by coating the CCD with an array of scintillating waveguides. In this paper, such waveguides were fabricated by first etching pores in silicon, then performing metallization or oxidation of the pore walls and finally filling the pores with CsI(TI). The resulting structures were observed using scanning electron microscopy and tested under X-ray exposure. Theoretical efficiencies of macropore arrays filled with CsI(TI) were also calculated, indicating that the optimal pore depth for metallized macropore arrays is about 80 mum while it is around 350 mum for oxidized ones. This result, together with the roughness of the metal coating, explains why lower SNR values were measured with the metallized macropores. Indeed, the macropore arrays had depths in the range of 210-390 mum, which is favorable to oxidized structures.
  •  
6.
  • Badel, Xavier, et al. (författare)
  • Performance of scintillating waveguides for CCD-based X-ray detectors
  • 2006
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 53:1, s. 3-8
  • Tidskriftsartikel (refereegranskat)abstract
    • Scintillating films are usually used to improve the sensitivity of CCD-based X-ray imaging detectors. For an optimal spatial resolution and detection efficiency, a tradeoff has to be made on the film thickness. However, these scintillating layers can also be structured to provide a pixellated screen. In this paper, the study of CsI(TI)-filled pore arrays is reported. The pores are first etched in silicon, then oxidized and finally filled with CsI(TI) to form scintillating waveguides. The dependence of the detector sensitivity on pore depth, varied from 40 to 400 mu m here, follows rather well theoretical predictions. Most of the detectors produced in this work have a detective quantum efficiency of the incoming X-ray photons of about 25%. However, one detector shows that higher efficiency can be achieved approaching almost the theoretical limit set by Poisson statistics of the incoming X-rays. Thus, we conclude that it is possible to fabricate scintillating waveguides with almost ideal performance. Imaging capabilities of the detectors are demonstrated.
  •  
7.
  • Bauer, Florian, et al. (författare)
  • Depth of interaction with a 3-dimensional checkerboard arrangement LSO-LSO block
  • 2010
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 57:3, s. 971-975
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to improve image quality in Positron Emission Tomography (PET) different routes are being pursued such as fast timing resolution for time-of-flight PET, higher spatial resolution by the use of smaller scintillator pixels and the use of depth-of-interaction information. The detection of the depth-of-interaction (DOI) of a gamma ray within a detector, deploying pulse shape discrimination (PSD), has been used to increase sensitivity and spatial resolution, especially at the edge of the field of view (FOV). The DOI information is used to reduce the parallax error; thus improving spatial resolution. Commonly, different scintillator materials with different decay times and light output and other differentiating factors, such as density, emission spectra, etc. are used for DOI detectors. We present a multi-layer phoswich detector comprised of LSO with different decay times in the range from 30 ns to 47 ns. The difference in decay times is achieved by co-doping LSO:Ce with Ca, resulting in short decay times of ~ 30 ns [1]. The use of a cut light guide allows the use of regular Photomultiplier tubes, giving the opportunity of a potential DOI detector replacement for current detectors. We were able to identify each pixel in the different detector layers
  •  
8.
  • Bauer, F., et al. (författare)
  • Dynode-Timing Method for PET Block Detectors
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 55:1, s. 451-456
  • Tidskriftsartikel (refereegranskat)abstract
    • The focus of this paper is the investigation of a new dynode-timing technique optimized for PET block detectors. This method allows utilization of dynode signals from single but especially multiple photo-multiplier tubes (PMTs), operated with negative high-voltage. The technique will provide an event-timing trigger without deteriorating the anode signal. A printed circuit board has been developed and built for this investigation. Benchmark measurements have been performed, comparing timing of the anode signal with timing of the inverted last-dynode signal and timing of the dynode signal extracted via a newly developed LVPECL-logic based board. Timing measurements were performed with plastic as well as LSO scintillators. From single PMT measurements we find a 30 ps improvement with the dynode-timing method compared to the standard anode timing with two Photonis XP2020Q PMTs with LSO (10 mmtimes10 mmtimes10 mm). For a quad-PMT block detector, assembled of four Hamamatsu R9800 with a Hi-Rez block, the timing-resolution improves ~10%, by 43 ps compared to the standard anode timing.
  •  
9.
  • Bauer, F., et al. (författare)
  • Measurements and Ray-Tracing Simulations of Light Spread in LSO Crystals
  • 2009
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 56:5, s. 2566-2573
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on measurements of the absolute light output from LSO crystals for irradiation with 511 keV gamma rays as a function of interaction position, reflector arrangement, detector coupling geometry and optical coupling to an adjacent crystal. The light output for this series of geometrical configurations is simulated with the ZEMAX ray-tracing software. By fine-tuning the optical parameters of the bulk and at the interfaces of the crystal, a model is obtained which yields good agreement with experimental data for all configurations. The resulting parameter set is applied to calculate the light distribution in a 12$,times,$ 12 crystal block detector. A comparison of measured and calculated block position profiles shows good agreement, demonstrating the potential of the simulation model to predict block detector performance data and provide guidelines for future array designs.
  •  
10.
  • Bauer, F., et al. (författare)
  • Performance Study of the New Hamamatsu R9779 and Photonis XP20D0 Fast 2" Photomultipliers
  • 2007
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 54:3, s. 422-426
  • Tidskriftsartikel (refereegranskat)abstract
    • The focus of this paper is the evaluation of the new fast 51 mm-diameter, 8-stage Hamamatsu R9779 photomultipliers (PMTs) with an acceleration-ring at the front-end and the Photonis XP20D0 PMTs with a screening grid in front of the anode. The following performance characteristics are presented: Timing resolution, anode-scan-uniformity and transit-time spread. The unfolded timing resolution for two R9779 was 192 ps and 210 ps using plastic scintillators. The individual timing resolutions for two XP20D0 using plastic scintillators are 181 ps and 154 ps, respectively. The variation in time resolution across the windows of the two R9779 ranged between 117 ps and 171 ps, and 79 ps and 73 ps for the two XP20D0 PMTs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 175
Typ av publikation
tidskriftsartikel (173)
konferensbidrag (2)
Typ av innehåll
refereegranskat (144)
övrigt vetenskapligt/konstnärligt (31)
Författare/redaktör
Eriksson, L (15)
Bohm, Christian (11)
Danielsson, Mats (11)
Klamra, Wlodzimierz (10)
Peskov, V. (8)
Eriksson, M (8)
visa fler...
Ljungberg, Michael (8)
Iacobaeus, C (8)
Eriksson, Lars (7)
Lund-Jensen, Bengt (7)
Fröjdh, Christer (7)
Conti, M (7)
Pearce, Mark (5)
Bornefalk, Hans (5)
Ostling, J (5)
Santin, G (5)
Bauer, F. (4)
Lund-Jensen, B. (4)
Silverstein, Samuel (4)
Hidvégi, Attila (4)
Carlson, Per (4)
Pavlopoulos, P (4)
Petersson, Sture (4)
Marciniewski, Pawel (4)
Hallén, Anders. (4)
Tokanai, F. (4)
Nieminen, P (4)
King, Michael A (4)
Karlsson, Staffan (4)
Linnros, Jan (4)
Persson, Mats (4)
Jansson, Peter, 1971 ... (4)
Hellman, Sten (3)
Gustafsson, L (3)
Campbell, M. (3)
Fröjdh, Christer, 19 ... (3)
Batsch, T. (3)
Calén, Hans (3)
Fransson, Kjell (3)
Larsson, Anne (3)
Nyberg, Johan, 1955- (3)
Svensson, Christer (3)
Wadsworth, R. (3)
Prokofiev, Alexander ... (3)
Swiderski, L. (3)
Thungström, Göran (3)
Puglisi, Donatella (3)
Gerardin, Simone (3)
Periale, L. (3)
Picchi, P. (3)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (49)
Karolinska Institutet (41)
Uppsala universitet (31)
Stockholms universitet (28)
Lunds universitet (17)
Mittuniversitetet (16)
visa fler...
Linköpings universitet (11)
Umeå universitet (3)
Chalmers tekniska högskola (3)
Högskolan i Gävle (2)
Luleå tekniska universitet (1)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (173)
Odefinierat språk (2)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (59)
Teknik (35)
Medicin och hälsovetenskap (9)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy