SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0391 3988 "

Sökning: L773:0391 3988

  • Resultat 1-10 av 77
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Al-Hwiesh, AK, et al. (författare)
  • Prevention of peritoneal dialysis catheter infections in Saudi peritoneal dialysis patients: the emergence of high-level mupirocin resistance
  • 2013
  • Ingår i: The International journal of artificial organs. - : SAGE Publications. - 1724-6040 .- 0391-3988. ; 36:7, s. 473-483
  • Tidskriftsartikel (refereegranskat)abstract
    • Exit-site infection (ESI) and peritonitis remain the major causes of morbidity and mortality in peritoneal dialysis (PD) patients. This study compared the effectiveness of local mupirocin ointment and gentamicin cream in preventing both gram-positive and gram-negative bacterial infections in PD patients. Methods Patients from two centers (n = 203) were assigned to daily mupirocin ointment or gentamicin cream application. Infections were tracked prospectively by organisms and expressed as episodes per patient-year for both ESI and peritonitis. Results The rate of gram-positive ESI was 0.31/episode/patient-year and 0.22 episodes/patient-year (p<0.05), whereas the rate of gram-negative ESI was 0.28 episode/patient-year and 0.11 episode/patient-year (p<0.01) in the mupirocin group and gentamicin group, respectively. Gram-positive ESI occurred in 17.1% vs 10.2% of patients (p<0.05), whereas 20% of and 5.1% of patients (p<0.001) had gram-negative ESI in the 2 groups respectively. S.aureus was cultured at exit-site in the mupirocin group in 27.8% patients, 60% (16.7% of the total Gram-positive isolates) of them being with high-level mupirocin-resistance. Pseudomonas aeruginosa was cultured in 21.8% of ESI in the mupirocin group, and in only 6.7% in the gentamicin group (p<0.01). Peritonitis rates were lower using gentamicin cream, 0.17 episode/patient-year compared with mupirocin, 0.39 episode/patient-year (p<0.01). With multivariate analysis, only gentamicin exit-site use was a significant predictor for lower catheter infection rate. Conclusion Prolonged use of mupirocin for ESI-prophylaxis is associated with the emergence of mupirocin-resistant S. aureus. Gentamicin cream is superior to mupirocin ointment in the prevention of PD catheter infections.
  •  
2.
  • Alquist, M, et al. (författare)
  • Development of a urea concentration gradient between muscle interstitium and plasma during hemodialysis
  • 1999
  • Ingår i: The International journal of artificial organs. - : SAGE Publications. - 0391-3988 .- 1724-6040. ; 22:12, s. 811-815
  • Tidskriftsartikel (refereegranskat)abstract
    • In this pilot study, muscle interstitial urea concentrations during hemodialysis (HD) were determined with a microdialysis technique and the results were compared with plasma water urea concentrations. Three patients were investigated during a total of five treatments. Under predialysis steady-state conditions, no difference was observed. During treatment, the muscle interstitial urea concentration was on average 19% higher (range 13–28%, n=4) than the plasma urea concentration after 17±3 min, 29% higher (25–31%, n=3) after 53±10 min, 40% higher (26–50%, n=3) after 117±6 min, 31% higher (26–34%, n= 3) after 179±5 min, and 31% higher (27–36%, n=4) after 231±5 min. The gradient declined after the conclusion of HD, muscle interstitial concentrations being on average 16% (9–26%, n=4) higher than plasma urea concentrations 9±2 min after treatment, and 8% (6–10%, n=3) 25±3 min after treatment. Thus, a urea concentration gradient with a higher concentration in muscle interstitium than in plasma, developed during HD, and dissipated gradually after treatment. This is consistent with blood flow-dependent urea sequestration in muscle tissue, causing intercompartment disequilibrium of urea during HD, and its consequent redistribution after treatment contributing to postdialysis urea rebound.
  •  
3.
  • Andersson, Roger, 1967-, et al. (författare)
  • Force to restore the shape of an asymmetric extracorporeal tube as the basis for non-invasive pressure measurements
  • 2002
  • Ingår i: International Journal of Artificial Organs. - 0391-3988 .- 1724-6040. ; 25:4, s. 281-289
  • Tidskriftsartikel (refereegranskat)abstract
    • A zero-balance principle is described where intraluminal pressure is estimated from the counter force needed to restore the tube shape of an elastic extra corporeal tube. The aim was to optimise cross-sectional tube geometry for tube expansion due to pressure and to reduce the sensitivity to variation in mechanical tube characteristics using an experimental statistical and factorial design. The main application is pressure monitoring in blood and dialysate tubes during hemodialysis. Improving the monitoring of the dialysis process will reduce complications, such as sudden decreases in systemic blood pressure or occlusion at the artero-venous fistula. The factorial design indicated strong influence from the geometrical characteristics of the tube as well from the geometrical design parameters of the pressure transducer. We found a consistent relationship between the intraluminal pressure and the applied force needed to restore the tube shape. The modified cross-sectional tube geometry enhances measurement sensitivity and facilitates the desired behavior of tubes during pressure applications.
  •  
4.
  •  
5.
  •  
6.
  • Belliato, M., et al. (författare)
  • An experimental model of veno-venous arterial extracorporeal membrane oxygenation
  • 2019
  • Ingår i: International Journal of Artificial Organs. - : SAGE Publications Ltd. - 0391-3988 .- 1724-6040.
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Veno-venous arterial extracorporeal membrane oxygenation is a hybrid-modality of extracorporeal membrane oxygenation combining veno-venous and veno-arterial extracorporeal membrane oxygenation. It may be applied to patients with both respiratory and cardio-circulatory failure. Aim: To describe a computational spreadsheet regarding an ex vivo experimental model of veno-venous arterial extracorporeal membrane oxygenation to determine the return of cannula pairs in a single pump–driven circuit. Methods: We developed an ex vivo model of veno-venous arterial extracorporeal membrane oxygenation with a single pump and two outflow cannulas, and a glucose solution was used to mimic the features of blood. We maintained a fixed aortic impedance and physiological pulmonary resistance. Both flow and pressure data were collected while testing different pairs of outflow cannulas. Six simulations of different cannula pairs were performed, and data were analysed by a custom-made spreadsheet, which was able to predict the flow partition at different flow levels. Results: In all simulations, the flow in the arterial cannula gradually increased differently depending on the cannula pair. The best cannula pair was a 19-Fr/18-cm arterial with a 17-Fr/50-cm venous cannula, where we observed an equal flow split and acceptable flow into the arterial cannula at a lower flow rate of 4 L/min. Conclusion: Our computational spreadsheet identifies the suitable cannula pairing set for correctly splitting the outlet blood flow into the arterial and venous return cannulas in a veno-venous arterial extracorporeal membrane oxygenation configuration without the use of external throttles. Several limitations were reported regarding fixed aortic impedance, central venous pressure and the types of cannulas tested; therefore, further studies are mandatory to confirm our findings.
  •  
7.
  • Biancari, Fausto, et al. (författare)
  • Inter-institutional analysis of the outcome after postcardiotomy veno-arterial extracorporeal membrane oxygenation
  • 2024
  • Ingår i: International Journal of Artificial Organs. - 0391-3988. ; 47:1, s. 25-34
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Patients requiring postcardiotomy veno-arterial extracorporeal membrane oxygenation (V-A-ECMO) have a high risk of early mortality. In this analysis, we evaluated whether any interinstitutional difference exists in the results of postcardiotomy V-A-ECMO. Methods: Studies on postcardiotomy V-A-ECMO were identified through a systematic review for individual patient data (IPD) meta-analysis. Analysis of interinstitutional results was performed using direct standardization, estimation of observed/expected in-hospital mortality ratio and propensity score matching. Results: Systematic review of the literature yielded 31 studies. Data from 10 studies on 1269 patients treated at 25 hospitals were available for the present analysis. In-hospital mortality was 66.7%. The relative risk of in-hospital mortality was significantly higher in six hospitals. Observed versus expected in-hospital mortality ratio showed that four hospitals were outliers with significantly increased mortality rates, and one hospital had significantly lower in-hospital mortality rate. Participating hospitals were classified as underperforming and overperforming hospitals if their observed/expected in-hospital mortality was higher or lower than 1.0, respectively. Among 395 propensity score matched pairs, the overperforming hospitals had significantly lower in-hospital mortality (60.3% vs 71.4%, p = 0.001) than underperforming hospitals. Low annual volume of postcardiotomy V-A-ECMO tended to be predictive of poor outcome only when adjusted for patients’ risk profile. Conclusions: In-hospital mortality after postcardiotomy V-A-ECMO differed significantly between participating hospitals. These findings suggest that in many centers there is room for improvement of the results of postcardiotomy V-A-ECMO.
  •  
8.
  • Broman, Mikael, et al. (författare)
  • Recirculation during veno-venous extra-corporeal membrane oxygenation - a simulation study
  • 2015
  • Ingår i: International Journal of Artificial Organs. - : SAGE Publications. - 0391-3988 .- 1724-6040. ; 38:1, s. 23-30
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Veno-venous ECMO is indicated in reversible life-threatening respiratory failure without life-threatening circulatory failure. Recirculation of oxygenated blood in the ECMO circuit decreases efficiency of patient oxygen delivery but is difficult to measure. We seek to identify and quantify some of the factors responsible for recirculation in a simulation model and compare with clinical data. Methods: A closed-loop real-time simulation model of the cardiovascular system has been developed. ECMO is simulated with a fixed flow pump 0 to 5 l/min with various cannulation sites -1) right atrium to inferior vena cava, 2) inferior vena cava to right atrium, and 3) superior+ inferior vena cava to right atrium. Simulations are compared to data from a retrospective cohort of 11 consecutive adult veno-venous ECMO patients in our department. Results: Recirculation increases with increasing ECMO-flow, decreases with increasing cardiac output, and is highly dependent on choice of cannulation sites. A more peripheral drainage site decreases recirculation substantially. Conclusions: Simulations suggest that recirculation is a significant clinical problem in veno-venous ECMO in agreement with clinical data. Due to the difficulties in measuring recirculation and interpretation of the venous oxygen saturation in the ECMO drainage blood, flow settings and cannula positioning should rather be optimized with help of arterial oxygenation parameters. Simulation may be useful in quantification and understanding of recirculation in VV-ECMO.
  •  
9.
  •  
10.
  • Dare, E.V., et al. (författare)
  • Differentiation of a fibrin gel encapsulated chondrogenic cell line
  • 2007
  • Ingår i: International Journal of Artificial Organs. - : Wichtig Editore. - 0391-3988 .- 1724-6040. ; 30:7, s. 619-627
  • Tidskriftsartikel (refereegranskat)abstract
    • Hyaline cartilage has very limited regenerative capacity following damage. Therefore engineered tissue substitutes have been the focus of much research. Our objective was to develop a fibrin-based scaffold as a cell delivery vehicle and template for hyaline cartilage regeneration, and compare its cellular properties against monolayer and pellet culture for chondrogenic cells. The chondrogenic precursor cell line, RCJ 3.1C5.18 (C5.18), was chosen as a test system for evaluating the effect of various culture conditions, including cell encapsulation, on articular chondrogenic cell differentiation. The C5.18 cells in monolayer showed elevated expression of collagen II, an articular chondrogenic marker, but also markers for fibrocartilage differentiation (collagen I and versican) when cultured with chondrogenic medium as compared to basic maintenance medium. Pellets of C5.18 cells cultured in chondrogenic medium were histologically more organized in structure than pellets cultured in control maintenance medium. The chondrogenic medium cultured pellets also secreted an extracellular matrix that was comprised of type II with very little type I collagen, indicating a trend towards a more hyaline-like cartilage. Moreover, when cultured in chondrogenic medium, fibrin-encapsulated C5.18 cells elaborated an extracellular matrix containing type II collagen, as well as aggrecan, which are both components of hyaline cartilage. This indicated a more articular-like chondrogenic differentiation for fibrin encapsulated C5.18 cells. The results of these experiments provide evidence that the C5.18 cell line can be used as a tool to evaluate potential scaffolds for articular cartilage tissue engineering.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 77
Typ av publikation
tidskriftsartikel (65)
konferensbidrag (10)
forskningsöversikt (2)
Typ av innehåll
refereegranskat (56)
övrigt vetenskapligt/konstnärligt (21)
Författare/redaktör
Lindholm, B (20)
Qureshi, AR (4)
Wang, T. (2)
Jonsson, P. (2)
Martin, P. (2)
Mangano, S. (2)
visa fler...
Li, F. (2)
Bergstrom, J (2)
Brännström, Thomas (2)
Stegmayr, B (2)
Liu, Y. (1)
Wang, J. (1)
Gomez, R. (1)
De Deyn, PP (1)
Svensson, L (1)
Massy, ZA (1)
Henein, Michael Y. (1)
Jacobson, SH (1)
Spittle, M (1)
Johansson, G. (1)
Magnusson, Martin (1)
Stenvinkel, P (1)
Kato, S. (1)
Anderstam, B (1)
Svenmarker, Pontus (1)
Lundberg, L (1)
Morris, A (1)
Gustafsson, Fredrik (1)
Nilsson Ekdahl, Kris ... (1)
Nilsson, Bo (1)
Fridolin, Ivo (1)
Mellgren, Karin, 196 ... (1)
Mellgren, G (1)
Wadenvik, Hans, 1955 (1)
Jakobson Mo, Susanna ... (1)
Hadimeri, Henrik (1)
Hadimeri, H (1)
Persson, B (1)
Isaksson, B (1)
Frenckner, B (1)
Hübbert, Laila (1)
Mustafa, Kamal (1)
Ask, Per, 1950- (1)
Karlsson, Daniel (1)
Rodriguez, M (1)
Ahn, Henrik Casimir (1)
Brännström, M (1)
Ramsauer, Bernd (1)
Lundahl, J (1)
Al-Hwiesh, AK (1)
visa färre...
Lärosäte
Umeå universitet (34)
Karolinska Institutet (33)
Linköpings universitet (10)
Kungliga Tekniska Högskolan (3)
Uppsala universitet (3)
Göteborgs universitet (2)
visa fler...
Jönköping University (1)
Lunds universitet (1)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (77)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (28)
Teknik (4)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy