SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0909 0495 OR L773:1600 5775 "

Sökning: L773:0909 0495 OR L773:1600 5775

  • Resultat 1-10 av 143
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Agåker, Marcus, et al. (författare)
  • A five-axis parallel kinematic mirror unit for soft X-ray beamlines at MAX IV
  • 2020
  • Ingår i: Journal of Synchrotron Radiation. - : INT UNION CRYSTALLOGRAPHY. - 0909-0495 .- 1600-5775. ; 27, s. 262-271
  • Tidskriftsartikel (refereegranskat)abstract
    • With the introduction of the multi-bend achromats in the new fourth-generation storage rings the emittance has decreased by an order of magnitude resulting in increased brightness. However, the higher brightness comes with smaller beam sizes and narrower radiation cones. As a consequence, the requirements on mechanical stability regarding the beamline components increases. Here an innovative five-axis parallel kinematic mirror unit for use with soft X-ray beamlines using off-axis grazing-incidence optics is presented. Using simulations and measurements from the HIPPIE beamline at the MAX IV Laboratory it is shown that it has no Eigen frequencies below 90 Hz. Its positioning accuracy is better than 25 nm linearly and 17-35 mu rad angularly depending on the mirror chamber dimensions.
  •  
2.
  • Agåker, Marcus, et al. (författare)
  • An ultra-high-stability four-axis ultra-high-vacuum sample manipulator
  • 2021
  • Ingår i: Journal of Synchrotron Radiation. - : International Union Of Crystallography. - 1600-5775 .- 0909-0495. ; 28:Pt 4, s. 1059-1068
  • Tidskriftsartikel (refereegranskat)abstract
    • A report on a four-axis ultra-high-stability manipulator developed for use at the Veritas and Species RIXS beamlines at MAX IV Laboratory, Lund, Sweden, is presented. The manipulator consists of a compact, light-weight X-Y table with a stiffened Z tower carrying a platform with a rotary seal to which a manipulator rod holding the sample can be attached. Its design parameters have been optimized to achieve high eigen-frequencies via a light-weight yet stiff construction, to absorb forces without deformations, provide a low center of gravity, and have a compact footprint without compromising access to the manipulator rod. The manipulator system can house a multitude of different, easily exchangeable, manipulator rods that can be tailor-made for specific experimental requirements without having to rebuild the entire sample positioning system. It is shown that the manipulator has its lowest eigen-frequency at 48.5 Hz and that long-term stability is in the few tens of nanometres. Position accuracy is shown to be better than 100 nm. Angular accuracy is in the 500 nrad range with a long-term stability of a few hundred nanoradians.
  •  
3.
  • Allahgholi, Aschkan, et al. (författare)
  • The Adaptive Gain Integrating Pixel Detector at the European XFEL
  • 2019
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 26, s. 74-82
  • Tidskriftsartikel (refereegranskat)abstract
    • The Adaptive Gain Integrating Pixel Detector (AGIPD) is an X-ray imager, custom designed for the European X-ray Free-Electron Laser (XFEL). It is a fast, low-noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 10(4)photons of 12keV. In burst mode the system is able to store 352 images while running at up to 6.5MHz, which is compatible with the 4.5MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.
  •  
4.
  • Almkvist, Gunnar, et al. (författare)
  • K-edge XANES analysis of sulfur compounds: an investigation of the relative intensities using internal calibration
  • 2010
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 17, s. 683-688
  • Tidskriftsartikel (refereegranskat)abstract
    • Sulfur K-edge XANES (X-ray absorption near-edge structure) spectroscopy is an excellent tool for determining the speciation of sulfur compounds in complex matrices. This paper presents a method to quantitatively determine the kinds of sulfur species in natural samples using internally calibrated reference spectra of model compounds Owing to significant self-absorption of formed fluorescence radiation in the sample itself the fluorescence signal displays a non-linear correlation with the sulfur content over a wide concentration range. Self-absorption is also a problem at low total absorption of the sample when the sulfur compounds are present as particles. The post-edge Intensity patterns of the sulfur K-edge XANES spectra vary with the type of sulfur compound, with reducing sulfur compounds often having a higher post-edge intensity than the oxidized forms. In dilute solutions (less than 0.3-0.5%) it is possible to use sulfur K-edge XANES reference data for quantitative analysis of the contribution from different species The results show that it is essential to use an internal calibration system when performing quantitative XANES analysis Preparation of unknown samples must take both the total absorption and possible presence of self-absorbing particles into consideration.
  •  
5.
  • Anderson, Danielle L., et al. (författare)
  • Spatial and temporal distribution of gamma H2AX fluorescence in human cell cultures following synchrotron-generated X-ray microbeams : lack of correlation between persistent gamma H2AX foci and apoptosis
  • 2014
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 21, s. 801-810
  • Tidskriftsartikel (refereegranskat)abstract
    • Formation of gamma H2AX foci (a marker of DNA double-strand breaks), rates of foci clearance and apoptosis were investigated in cultured normal human fibroblasts and p53 wild-type malignant glioma cells after exposure to high-dose synchrotron-generated microbeams. Doses up to 283 Gy were delivered using beam geometries that included a microbeam array (50 mu m wide, 400 mu m spacing), single microbeams (60-570 mu m wide) and a broad beam (32 mm wide). The two cell types exhibited similar trends with respect to the initial formation and time-dependent clearance of gamma H2AX foci after irradiation. High levels of gamma H2AX foci persisted as late as 72 h post-irradiation in the majority of cells within cultures of both cell types. Levels of persistent foci after irradiation via the 570 mu m microbeam or broad beam were higher when compared with those observed after exposure to the 60 mu m microbeam or microbeam array. Despite persistence of gamma H2AX foci, these irradiation conditions triggered apoptosis in only a small proportion (<5%) of cells within cultures of both cell types. These results contribute to the understanding of the fundamental biological consequences of high-dose microbeam irradiations, and implicate the importance of non-apoptotic responses such as p53-mediated growth arrest (premature senescence).
  •  
6.
  • Bergmann, U, et al. (författare)
  • High-resolution X-ray spectroscopy of rare events : a different look at local structure and chemistry
  • 2001
  • Ingår i: Journal of Synchrotron Radiation. - Univ Calif Berkeley, Lawrence Berkeley Lab, Phys Biosci Div, Berkeley, CA 94720 USA. Univ Calif Davis, Dept Appl Sci, Davis, CA 95616 USA. CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA. : MUNKSGAARD INT PUBL LTD. - 0909-0495 .- 1600-5775. ; 8, s. 199-203
  • Tidskriftsartikel (refereegranskat)abstract
    • The combination of large-acceptance high-resolution X-ray optics with bright synchrotron sources permits quantitative analysis of rare events such as X-ray fluorescence from very dilute systems, weak fluorescence transitions or X-ray Raman scattering. Transition-metal K beta fluorescence contains information about spin and oxidation state; examples of the characterization of the Mn oxidation states in the oxygen-evolving complex of photosystem II and Mn-consuming spores from the marine bacillus SG-1 are presented. Weaker features of the K beta spectrum resulting from valence-level and 'interatomic' ligand to metal transitions contain detailed information on the ligand-atom type, distance and orientation. Applications of this spectral region to characterize the local structure of model compounds are presented. X-ray Raman scattering (XRS) is an extremely rare event, but also represents a unique technique to obtain bulk-sensitive low-energy (<600 eV) X-ray absorption fine structure (XAFS) spectra using hard ( 10 keV) X-rays. A photon is inelastically scattered, losing part of its energy to promote an electron into an unoccupied level. In many cases, the cross section is proportional to that of the corresponding absorption process yielding the same X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) features. XRS finds application for systems that defy XAFS analysis at low energies, e.g. liquids or highly concentrated complex systems, reactive compounds and samples under extreme conditions (pressure, temperature). Recent results are discussed.
  •  
7.
  • Blomberg, Sara, et al. (författare)
  • Combining synchrotron light with laser technology in catalysis research
  • 2018
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775 .- 0909-0495. ; 25:5, s. 1389-1394
  • Tidskriftsartikel (refereegranskat)abstract
    • High-energy surface X-ray diffraction (HESXRD) provides surface structural information with high temporal resolution, facilitating the understanding of the surface dynamics and structure of the active phase of catalytic surfaces. The surface structure detected during the reaction is sensitive to the composition of the gas phase close to the catalyst surface, and the catalytic activity of the sample itself may affect the surface structure, which in turn may complicate the assignment of the active phase. For this reason, planar laser-induced fluorescence (PLIF) and HESXRD have been combined during the oxidation of CO over a Pd(100) crystal. PLIF complements the structural studies with an instantaneous two-dimensional image of the CO2 gas phase in the vicinity of the active model catalyst. Here the combined HESXRD and PLIF operandomeasurements of CO oxidation over Pd(100) are presented, allowing for an improved assignment of the correlation between sample structure and the CO2distribution above the sample surface with sub-second time resolution.
  •  
8.
  • Bora, D. K., et al. (författare)
  • Influence of crystal structure, ligand environment and morphology on Co L-edge XAS spectral characteristics in cobalt compounds
  • 2015
  • Ingår i: Journal of Synchrotron Radiation. - : International Union of Crystallography (IUCr). - 0909-0495 .- 1600-5775. ; 22, s. 1450-1458
  • Tidskriftsartikel (refereegranskat)abstract
    • The electronic structure of a material plays an important role in its functionality for different applications which can be probed using synchrotron-based spectroscopy techniques. Here, various cobalt-based compounds, differing in crystal structure, ligands surrounding the central metal ion and morphology, have been studied by soft X-ray absorption spectroscopy (XAS) at the Co L-edge in order to measure the effect of these parameters on the electronic structure. A careful qualitative analysis of the spectral branching ratio and relative intensities of the L 3 and L 2 peaks provide useful insight into the electronic properties of compounds such as CoO/Co(OH)2, CoCl2.6H2O/CoF2.4H2O, CoCl2/CoF2, Co3O4 (bulk/nano/micro). For further detailed analysis of the XAS spectra, quantitative analysis has been performed by fitting the spectral profile with simulated spectra for a number of cobalt compounds using crystal field atomic multiplet calculations.
  •  
9.
  • Bouchet, Audrey, et al. (författare)
  • Chalcone JAI-51 improves efficacy of synchrotron microbeam radiation therapy of brain tumors
  • 2012
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 19, s. 478-482
  • Tidskriftsartikel (refereegranskat)abstract
    • Microbeam radiation therapy (MRT), a preclinical form of radiosurgery, uses spatially fractionated micrometre-wide synchrotron-generated X-ray beams. As MRT alone is predominantly palliative for animal tumors, the effects of the combination of MRT and a newly synthesized chemotherapeutic agent JAI-51 on 9L gliosarcomas have been evaluated. Fourteen days (D14) after implantation (D0), intracerebral 9LGS-bearing rats received either MRT, JAI-51 or both treatments. JAI-51, alone or immediately after MRT, was administered three times per week. Animals were kept up to similar to 20 weeks after irradiation or sacrificed at D16 or D28 after treatment for cell cycle analysis. MRT plus JAI-51 increased significantly the lifespan compared with MRT alone (p = 0.0367). JAI-51 treatment alone had no effect on rat survival. MRT alone or associated with JAI-51 induced a cell cycle blockade in G2/M (p < 0.01) while the combined treatment also reduced the proportion of G0/G1 cells. At D28 after irradiation, MRT and MRT/JAI-51 had a smaller cell blockade effect in the G2/M phase owing to a significant increase in tumor cell death rate (<2c) and a proportional increase of endoreplicative cells (>8c). The combination of MRT and JAI-51 increases the survival of 9LGS-bearing rats by inducing endoreduplication of DNA and tumor cell death; further, it slowed the onset of tumor growth resumption two weeks after treatment.
  •  
10.
  • Butorin, Sergei, et al. (författare)
  • X-ray spectroscopic study of chemical state in uranium carbides
  • 2022
  • Ingår i: Journal of Synchrotron Radiation. - : International Union of Crystallography (IUCr). - 0909-0495 .- 1600-5775. ; 29, s. 295-302
  • Tidskriftsartikel (refereegranskat)abstract
    • UC and UMeC2 (Me = Fe, Zr, Mo) carbides were studied by the high-energyresolution fluorescence-detected X-ray absorption (HERFD-XAS) technique at the U M-4 and L-3 edges. Both U M-4 and L-3 HERFD-XAS reveal some differences between UMeC2 and UC; there are differences also between the M-4 and L-3 edge results for both types of carbide in terms of the spectral width and energy position. The observed differences are attributed to the consequences of the U 5f, 6d-4d(3d) hybridization in UMeC2. Calculations of the U M-4 HERFD-XAS spectra were also performed using the Anderson impurity model (AIM). Based on the analysis of the data, the 5f occupancy in the ground state of UC was estimated to be 3.05 electrons. This finding is also supported by the analysis of U N-4,N-5 XAS of UC and by the results of the AIM calculations of the U 4f X-ray photoelectron spectrum of UC.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 143
Typ av publikation
tidskriftsartikel (143)
Typ av innehåll
refereegranskat (141)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Tarawneh, Hamed (11)
Kahnt, Maik (7)
Kalbfleisch, Sebasti ... (7)
Weninger, Clemens (6)
Carbone, Dina (6)
Johansson, Ulf (5)
visa fler...
Caleman, Carl (5)
Urpelainen, Samuli (5)
Graafsma, Heinz (5)
Björling, Alexander (5)
Ursby, Thomas (5)
Wallentin, Jesper (4)
Såthe, Conny (4)
Sjöblom, Peter (4)
Knudsen, Jan (4)
Sala, Simone (4)
Nan, Jie (4)
Timneanu, Nicusor (4)
Arvanitis, D (4)
Zhang, Yuhe (4)
Villanueva Perez, Pa ... (4)
Schnadt, Joachim (4)
Larsson, Emanuel (4)
Matej, Zdenek (4)
Lidon-Simon, Julio (4)
Szlachetko, Jakub (3)
Schroer, Christian G ... (3)
Plivelic, Tomás S. (3)
Agåker, Marcus (3)
Åhnberg, Karl (3)
Pärna, Rainer (3)
Svensson, Christer (3)
Al Dmour, Eshraq (3)
Bonetti, Stefano (3)
Boutet, Sébastien (3)
Thunnissen, Marjolei ... (3)
Thorin, Sara (3)
Bech, Martin (3)
Shoeman, Robert L (3)
Chapman, Henry N. (3)
Dunn, JH (3)
Johansson, Niclas (3)
Hennies, Franz (3)
Bell, Paul (3)
Uhlig, Jens (3)
Klementiev, Konstant ... (3)
Tromba, Giuliana (3)
Jönsson, H. Olof (3)
Eguiraun, Mikel (3)
Chayanun, Lert (3)
visa färre...
Lärosäte
Lunds universitet (83)
Uppsala universitet (34)
Kungliga Tekniska Högskolan (15)
Stockholms universitet (8)
Linköpings universitet (6)
Mittuniversitetet (6)
visa fler...
Chalmers tekniska högskola (6)
RISE (4)
Göteborgs universitet (3)
Högskolan i Halmstad (2)
Malmö universitet (2)
Karolinska Institutet (2)
Umeå universitet (1)
Högskolan i Gävle (1)
Sveriges Lantbruksuniversitet (1)
visa färre...
Språk
Engelska (143)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (134)
Teknik (8)
Medicin och hälsovetenskap (6)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy