SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0946 2171 "

Sökning: L773:0946 2171

  • Resultat 1-10 av 174
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hellström, Jonas, et al. (författare)
  • Efficient Yb : KGW lasers end-pumped by high-power diode bars
  • 2006
  • Ingår i: Applied physics. B, Lasers and optics (Print). - : Springer Science and Business Media LLC. - 0946-2171 .- 1432-0649. ; 82:2, s. 235-239
  • Tidskriftsartikel (refereegranskat)abstract
    • The laser performance of Yb:KGW under end-pumping with high-power diode bars has been investigated. In one configuration, the pump is delivered through an optical fiber yielding a symmetric but unpolarized pump spot. In the second configuration, the pump is delivered through an optical lens system yielding a polarized but asymmetric pump spot. Both configurations resulted in a maximum optical to optical efficiency of 47% and a maximum power of 12.4 W has been generated with the fiber coupled pump source. The output power was limited by crystal fracture, which occurred at an estimated temperature gradient of 1.2 x 10(5) K/m. Thermal lensing and laser tuning characteristics are also investigated.
  •  
2.
  • Abou Nada, Fahd Jouda, et al. (författare)
  • Improved measurement precision in decay time‑based phosphor thermometry
  • 2016
  • Ingår i: Applied Physics B. - : Springer Science and Business Media LLC. - 1432-0649 .- 0946-2171. ; 122
  • Tidskriftsartikel (refereegranskat)abstract
    • This study comprises a continuation of the previous efforts of the authors to characterize different sources of errors in phosphor thermometry based on the determination of luminescence decays from thermographic phosphors. Whereas earlier investigations focused on point detectors utilizing different sensor technology, this work presents a comparison of four PMTs that are identical in terms of their product type. These detectors are supposedly identical, but the investigations revealed that their response is strictly individual. This study also shows a linear excitation energy dependence for the decay time of cadmium tungstate (CdWO4), the phosphor being used in this work. In addition, the potential influence of the intense and short fluorescence peak preceding the weaker and longer exponential decay in some phosphor materials, was investigated using the electrical signal gating capability of the PMT. Finally, the evaluated decay time also appeared to be affected by the oscilloscope settings used when recording the phosphorescence signals. The presented results indicate that all operating parameters from the calibration measurement need to be rigorously reproduced in order to avoid systematic temperature errors in phosphor thermometry experiments that are based on reproducible measurements of the decay time. These results should be of more general interest also outside the phosphor community as the findings, presented herein, in principal concern all kinds of measurements that are dependent on reproducible measurements of signal shapes or time-transients.
  •  
3.
  • Afzelius, Mikael, et al. (författare)
  • Dual-broadband rotational CARS modelling of nitrogen at pressures up to 9 MPa. I. Inter-branch interference effect
  • 2002
  • Ingår i: Applied Physics B. - : Springer Science and Business Media LLC. - 0946-2171. ; 75:6-7, s. 763-769
  • Tidskriftsartikel (refereegranskat)abstract
    • An improved model for pure rotational coherent anti-Stokes Raman scattering (CARS) has been developed or the dual-broadband approach. This model takes into account the fact that coherent anti-Stokes as well as Stokes radiation are generated simultaneously, and these two branches overlap and interact at high pressures giving rise to an inter-branch interference effect. In combustion studies, the anti-Stokes branch is used to determine temperature and concentrations of key species, of which nitrogen is the most widely used, and we have found that the interference effect on the anti-Stokes side is of such magnitude that it clearly needs to be taken into account at pressures of a few MPa. The necessary modifications to the total third-order susceptibility are presented and a derivation of the convolution integral for a finite-bandwidth pump source is given.
  •  
4.
  • Afzelius, Mikael, et al. (författare)
  • Dual-broadband rotational CARS modelling of nitrogen at pressures up to 9 MPa. II. Rotational Raman line widths
  • 2002
  • Ingår i: Applied Physics B. - : Springer Science and Business Media LLC. - 0946-2171. ; 75:6-7, s. 771-778
  • Tidskriftsartikel (refereegranskat)abstract
    • Rotational coherent anti-Stokes Raman spectroscopy (CARS) is a well-established spectroscopic technique for thermometry at pre-combustion temperatures an atmospheric pressure. However, at pressures of several MPa, a previous investigation revealed large discrepancies between experimental data and the theoretical model. A re-evaluation has been made of these data (at room temperature and in the range 1.5-9 MPa) with two improvements to the spectral code. The first is the inclusion of an inter-branch interference effect, which is described in detail in Paper I. The second is the use of experimental S-1-branch Raman line widths measured at 295 K, with a temperature dependence extracted from semi-classical calculations following the Robert-Bonamy formalism. It is shown that these two modifications significantly improve the theoretical model, since both the spectral fits and the accuracy of the evaluated temperatures are considerably improved.
  •  
5.
  • Aldén, Marcus, et al. (författare)
  • Applications of two-photon absorption for detection of CO in combustion gases
  • 1984
  • Ingår i: Applied Physics B. - 0946-2171. ; 33:4, s. 205-208
  • Tidskriftsartikel (refereegranskat)abstract
    • Laser-induced fluorescence has been used for detection of CO in different environments. The fluorescence light was obtained by using a two-photon transition between theX1?- and theB1?- electronical states around 230 nm. Cell measurements indicate a detection limit lower than 0.1 ppm. Measurements in a CH4/air flame and in a low pressure dc discharge were realized with a diode-array detector, which was used in an imaging mode, permitting single-shot CO distributions to be captured.
  •  
6.
  •  
7.
  • Alnis, Janis, et al. (författare)
  • Laser spectroscopy of free molecular oxygen dispersed in wood materials
  • 2003
  • Ingår i: Applied Physics B. - : Springer Science and Business Media LLC. - 0946-2171 .- 1432-0649. ; 77:6-7, s. 691-695
  • Tidskriftsartikel (refereegranskat)abstract
    • The recently introduced Gas in Scattering Media Absorption Spectroscopy (GASMAS) technique is applied to the study of various wood samples. Molecular oxygen in the pores of the strongly scattering material is detected using diode laser spectroscopy around 760 nm. Diffuse light propagation in these media is studied by time-dispersion measurements. Furthermore, anisotropy related to the fibre structure of wood and gas diffusion properties are studied. Promising extensions of the experiments are discussed.
  •  
8.
  • Alonso, Benjamin, et al. (författare)
  • Characterization of sub-two-cycle pulses from a hollow-core fiber compressor in the spatiotemporal and spatiospectral domains
  • 2013
  • Ingår i: Applied Physics B. - : Springer Science and Business Media LLC. - 0946-2171 .- 1432-0649. ; 112:1, s. 105-114
  • Tidskriftsartikel (refereegranskat)abstract
    • We have post-compressed 25 fs (Fourier limit) amplified pulses in an argon-filled hollow-core fiber. The output pulses were compressed using a pair of wedges and chirped mirrors down to 4.5 fs (Fourier limit of 4.1 fs), which corresponds to less than two optical cycles. We then performed the characterization of the pulses by combining the d-scan and the STARFISH techniques. The temporal (and spectral) measurement of the pulses is done with d-scan, which is used as the reference to extend the characterization to the spatiotemporal (and spatiospectral) amplitude and phase of the pulses by means of STARFISH. The post-compressed pulses at the output of the hollow-fiber had an energy of 150 mu J. The analysis of the pulses revealed larger spectral broadening and blue-shift, and shorter duration at the center of the beam. For the first time, we demonstrate the complete characterization of intense ultra-broadband pulses in the sub-two-cycle regime, which provides an improved insight into the properties (space-time and space-frequency) of the pulses and is highly relevant for their applications.
  •  
9.
  • Aurand, Bastian, et al. (författare)
  • Reduction of X-ray generation in high-intensity laser ion acceleration
  • 2015
  • Ingår i: Applied Physics B. - : Springer Science and Business Media LLC. - 0946-2171 .- 1432-0649. ; 118:2, s. 247-251
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we report on measurements of bremsstrahlung in laser ion acceleration experiments from ultra-thin, polymer-based target foils. The influence of laser polarization on the generated radiation, the maximum achievable proton energy and the total proton number is investigated. A clear benefit in terms of radiation reduction by the use of circular polarized light can be observed. At the same time, the total number of accelerated protons was increased.
  •  
10.
  • Axelsson, Boman, et al. (författare)
  • Laser-induced incandescence for soot particle size and volume fraction measurements using on-line extinction calibration
  • 2001
  • Ingår i: Applied Physics B. - : Springer Science and Business Media LLC. - 0946-2171 .- 1432-0649. ; 72:3, s. 367-372
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel technique for two-dimensional measurements of soot volume fraction and particle size has been developed. It is based on a combined measurement of extinction and laser-induced incandescence using Nd:YAG laser wavelengths of 532 nm and 1064 nm. A low-energy laser pulse at 532 nm was used for extinction measurements and was followed by a more intense pulse at 1064 nm, delayed by 15 ns, for LII measurements. The 532-nm beam was split into a signal beam passing the flame and a reference beam, both of which were directed to a dye cell. The resulting fluorescence signals, from which the extinction was deduced, together with the LII signal, were registered on a single CCD detector. Thus the two-dimensional LII image could be converted to a soot volume fraction map through a calibration procedure during the same laser shot. The soot particle sizes were evaluated from the ratio of the temporal LII signals at two gate time positions. The uncertainty in the particle sizing arose mainly from the low signal for small particles at long gate times and the uncertainty in the flame temperature. The technique was applied to a well-characterized premixed flat flame, the soot properties of which had been previously thoroughly investigated.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 174
Typ av publikation
tidskriftsartikel (173)
konferensbidrag (1)
Typ av innehåll
refereegranskat (173)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Aldén, Marcus (26)
Svanberg, Sune (26)
Bengtsson, Per-Erik (21)
Laurell, Fredrik (17)
Li, Zhongshan (11)
Somesfalean, Gabriel (9)
visa fler...
Edner, Hans (6)
Schmidt, Florian M. (5)
Bengtsson, P. E. (5)
Zhang, Z. G. (5)
Axner, Ove (5)
Weibring, Petter (5)
Wahlström, Claes-Gör ... (4)
Bood, Joakim (4)
Omrane, Alaa (4)
L'Huillier, Anne (4)
Zetterberg, Johan (3)
Duan, Zheng (3)
Richter, Mattias (3)
Andersson-Engels, St ... (3)
Sjöholm, Mikael (3)
Holmlid, Leif, 1942 (3)
Mevel, E (3)
Persson, Linda (3)
Axner, Ove, 1957- (3)
Foltynowicz, Aleksan ... (2)
Svensson, Tomas (2)
Rupinski, M. (2)
Andersson, Mats (2)
Adolfsson, Erik (2)
Persson, Anders (2)
Friberg, Ari T. (2)
Svanberg, Katarina (2)
Afzelius, Mikael (2)
Brackmann, Christian (2)
Bood, J (2)
Dreier, T (2)
Tiihonen, Mikael (2)
Zhou, Bo (2)
Karlsson, H (2)
Cai, Y (2)
Johansson, Bengt (2)
Cecchi, G (2)
Pantani, L (2)
Martinsson, L. (2)
Tcherbakoff, O. (2)
Larsson, Jörgen (2)
Johnsson, Per (2)
Mauritsson, Johan (2)
Xu, Can (2)
visa färre...
Lärosäte
Lunds universitet (102)
Kungliga Tekniska Högskolan (41)
Umeå universitet (19)
Göteborgs universitet (4)
RISE (4)
Uppsala universitet (3)
visa fler...
Chalmers tekniska högskola (3)
Luleå tekniska universitet (2)
Linköpings universitet (2)
Malmö universitet (1)
visa färre...
Språk
Engelska (174)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (151)
Teknik (18)
Medicin och hälsovetenskap (3)
Lantbruksvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy