SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0956 5663 "

Sökning: L773:0956 5663

  • Resultat 1-10 av 304
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Mosbach, M., et al. (författare)
  • A miniaturised electrochemical affinity assay based on a wall-free sample droplet and micro-dispensing of the redox-labelled binding partner
  • 2001
  • Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 16:9-12, s. 611-620
  • Tidskriftsartikel (refereegranskat)abstract
    • An affinity-assay was developed that is based on the modulation of the diffusion coefficient of a redox-labelled hapten upon complementary recognition of the analyte leading to an increase of molecular weight and hence to a decrease of the diffusion coefficient. The slower diffusion is monitored by means of cyclic voltammetry. In order to demonstrate the feasibility of this assay format, recognition of biotin by streptavidin has been chosen as a model system. Labelling of biotin was achieved by covalent binding of a ferrocene derivative to the biotin unit. To reduce the consumption of expensive compounds and to allow automatisation of the assay a novel miniaturised set-up was developed based on a wall-free sample droplet which forms the electrochemical cell with typical volumes of up to 10 mul. This droplet is dispensed by means of a step-motor driven syringe pump through a specially designed electrode holder spanning the gap between a micro-working electrode and a macroscopic counter electrode. By means of a piezo-driven micro-dispenser a predefined number of nano-droplets (100 pl volume each) containing the redox-labelled hapten are shot into the sample droplet. By this, any physical contact and hence any cross-contamination between the sample and the reagent solution could be avoided. Signal amplification can be achieved by redox recycling between the micro-electrode and the perpendicular positioned macroscopic counter electrode. (C) 2001 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Mosbach, M, et al. (författare)
  • Picodroplet-deposition of enzymes on functionalized self-assembled monolayers as a basis for miniaturized multi-sensor structures
  • 2001
  • Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 16:9-12, s. 827-837
  • Tidskriftsartikel (refereegranskat)abstract
    • We are reporting on a novel approach for structured immobilisation of enzymes on gold surfaces modified with monolayers of functionalised alkylthiols. The formation of enzyme spots is achieved by shooting very small volumes of an appropriate enzyme solution (down to 100 pl) onto a thiol-monolayer modified gold surface using a micro-dispenser. Formation of enzyme patterns is obtained by moving the micro-dispenser relative to the modified gold surface using a micro-positioning device. Enzyme spots with typical lateral dimensions of 100 ml are obtained, but also, more complex structures, e.g. lines or meander structures, can be achieved by multiple droplets dispensed during the concomitant movement of the micro-dispenser. The first enzyme layer on top of the functionalised thiol-monolayer is subsequently covalently immobilised using either carbodiimide activation of carboxilic headgroups at the enzyme or via already introduced activated ester functions at the monolayer. Immobilised enzyme activities of glucose oxidase and lactate oxidase patterns have been characterised by means of scanning electrochemical microscopy. The product of the enzyme-catalysed reaction, H2O2, is detected with an micro-electrode in the presence of either or both substrates, glucose and lactate, leading to a visualisation of the corresponding enzyme pattern and the lateral enzymatic activity. (C) 2001 Elsevier Science B.V. All rights reserved.
  •  
3.
  • Ramanathan, Kumaran, et al. (författare)
  • Gold-coated capillary based 2,4-dichlorophenoxyacetic acid chemi-lumincscent assays: possibilities towards multianalysis
  • 2002
  • Ingår i: Biosensors and Bioelectronics. - 0956-5663. ; 17:4, s. 283-288
  • Konferensbidrag (refereegranskat)abstract
    • The application of gold-coated glass capillaries for the design of a sensitive chemiluminescent immunoassay for 2,4-dichlorophenoxyacetic acid (2,4-D) is reported. The gold coating on the glass capillaries has been partially characterized and its effect on enhancing the signal intensity has been measured. A simple photo-multiplier tube-based photon detector is used for this purpose. At least three times improvement in the signal intensity is observed compared to uncoated glass capillaries, with a consequent improvement in the sensitivity of detection. Using such gold-coated glass capillaries, 2,4-D in the range 10(-9) to 10(-13) mol/l is detectable at a precision of +/-15% (CV%) and a limit of detection of 10(-15) mol/l is achievable. The possibility of using such gold-coated capillaries with a portable multianalytical set-up for field studies is also demonstrated.
  •  
4.
  • Tkac, Jan, et al. (författare)
  • Improved selectivity of microbial biosensor using membrane coating. Application to the analysis of ethanol during fermentation
  • 2003
  • Ingår i: Biosensors & bioelectronics. - 0956-5663 .- 1873-4235. ; 18:9, s. 1125-1134
  • Tidskriftsartikel (refereegranskat)abstract
    • A ferricyanide mediated microbial biosensor for ethanol detection was prepared by surface modification of a glassy carbon electrode. The selectivity of the whole Gluconobacter oxydans cell biosensor for ethanol determination was greatly enhanced by the size exclusion effect of a cellulose acetate (CA) membrane. The use of a CA membrane increased the ethanol to glucose sensitivity ratio by a factor of 58.2 and even the ethanol to glycerol sensitivity ratio by a factor of 7.5 compared with the use of a dialysis membrane. The biosensor provides rapid and sensitive detection of ethanol with a limit of detection of 0.85 µM (S/N=3). The selectivity of the biosensor toward alcohols was better compared to previously published enzyme biosensors based on alcohol oxidase or alcohol dehydrogenases. The biosensor was successfully used in an off-line monitoring of ethanol during batch fermentation by immobilized Saccharomyces cerevisiae cells with an initial glucose concentration of 200 g l-1. © 2002 Elsevier Science B.V. All rights reserved.
  •  
5.
  • Önnerfjord, Patrik, et al. (författare)
  • Tyrosinase graphite-epoxy based composite electrodes for detection of phenols
  • 1995
  • Ingår i: Biosensors and Bioelectronics. - 0956-5663. ; 10:6-7, s. 607-619
  • Tidskriftsartikel (refereegranskat)abstract
    • The characterization and analytical performance of a tyrosinase graphite-epoxy electrode for the detection of phenolic compounds are described. The biocomposite configuration is based on the entrapment of commercially available tyrosinase in a graphite-epoxy matrix, and the mixing of the resulting conductive epoxy resin with a hardener. The enzyme electrode is mounted as a working electrode in an amperometric flow cell of the confined wall-jet type and studied in the flow injection mode. The bioprobe is electrochemically characterized by hydrodynamic and cyclic voltammetry for catechol and phenol. An applied potential of -100 mV vs. Ag/AgCl is found to be optimal for electrochemical reduction of the enzyme products (quinone forms) for the biocomposite electrode. The dependence of the response of the biocomposite on the flow rate, the amount of loaded enzyme, the buffer composition, pH, and oxygen is investigated. The response of the biosensor to different phenolic compounds is also evaluated. The limits of detection (S/N = 3) for phenol and catechol were 1·0 μM and 0·04 μM, respectively. No loss in response could be detected after 100 injections of catechol (R.S.D. <2%). Stability of the biocomposite depends on storage conditions. Theoretical advantages described in the literature for biocomposite electrodes, for example, repolishing and bulk modification, are empirically studied in this work.
  •  
6.
  • Alcock, S. J., et al. (författare)
  • Advances in the use of  in vivo sensors
  • 1992
  • Ingår i: Biosensors & bioelectronics. - : Elsevier. - 0956-5663 .- 1873-4235. ; 7:4, s. 243-254
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The sixth workshop of the European Community Concerted Action on Chemical sensors for in vivo monitoring was held at Snogeholm, Sweden, in October 1991. The meeting reviewed recent in vivo and ex vivo results, and also included a shorter session on ethical and safety problems.
  •  
7.
  • Bachinger, T., et al. (författare)
  • Gas sensor arrays for early detection of infection in mammalian cell culture
  • 2002
  • Ingår i: Biosensors & bioelectronics. - 0956-5663 .- 1873-4235. ; 17:5, s. 395-403
  • Tidskriftsartikel (refereegranskat)abstract
    • The detection of bacterial infections in a mammalian cell culture process is realised using a gas sensor array. In production-scale and laboratory-scale cultivations of a perfused recombinant CHO-cell culture producing human blood coagulation Factor VIII, we show that the gas sensor array identifies bacterial contamination earlier than conventional methods. The sensitivity of the instrument is verified by inoculation of a blank cell culture medium with defined bacterial cell counts. © 2002 Elsevier Science B.V. All rights reserved.
  •  
8.
  • Filippini, Daniel, et al. (författare)
  • Microplate based biosensing with a computer screen aided technique
  • 2003
  • Ingår i: Biosensors & bioelectronics. - 0956-5663 .- 1873-4235. ; 19:1, s. 35-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Melanophores, dark pigment cells from the frog Xenopus laevis, have the ability to change light absorbance upon stimulation by different biological agents. Hormone exposure (e.g. melatonin or α-melanocyte stimulating hormone) has been used here as a reversible stimulus to test a new compact microplate reading platform. As an application, the detection of the asthma drug formoterol in blood plasma samples is demonstrated. The present system utilizes a computer screen as a (programmable) large area light source, and a standard web camera as recording media enabling even kinetic microplate reading with a versatile and broadly available platform, which suffices to evaluate numerous bioassays. Especially in the context of point of care testing or self testing applications these possibilities become advantageous compared with highly dedicated comparatively expensive commercial systems.
  •  
9.
  •  
10.
  • Gabig-Ciminska, Magdalena, et al. (författare)
  • Electric chips for rapid detection and quantification of nucleic acids
  • 2004
  • Ingår i: Biosensors & bioelectronics. - : Elsevier BV. - 0956-5663 .- 1873-4235. ; 19:6, s. 537-546
  • Tidskriftsartikel (refereegranskat)abstract
    • A silicon chip-based electric detector coupled to bead-based sandwich hybridization (BBSH) is presented as an approach to perform rapid analysis of specific nucleic acids. A microfluidic platform incorporating paramagnetic beads with immobilized capture probes is used for the biorecognition steps. The protocol involves simultaneous sandwich hybridization of a single-stranded nucleic acid target with the capture probe on the beads and with a detection probe in the reaction solution, followed by enzyme labeling of the detection probe, enzymatic reaction, and finally, potentiometric measurement of the enzyme product at the chip surface. Anti-DIG-alkaline phosphatase conjugate was used for the enzyme labeling of the DIG-labeled detection probe. p-Aminophenol phosphate (pAPP) was used as a substrate. The enzyme reaction product, p-aminophenol (pAP), is oxidized at the anode of the chip to quinoneimine that is reduced back to pAP at the cathode. The cycling oxidation and reduction of these compounds result in a current producing a characteristic signal that can be related to the concentration of the analyte. The performance of the different steps in the assay was characterized using in vitro synthesized RNA oligonucleotides and then the instrument was used for analysis of 16S rRNA in Escherichia coli extract. The assay time depends on the sensitivity required. Artificial RNA target and 16S rRNA, in amounts ranging from 10(11) to 10(10) molecules, were assayed within 25 min and 4 h, respectively.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 304
Typ av publikation
tidskriftsartikel (289)
forskningsöversikt (10)
recension (3)
konferensbidrag (2)
Typ av innehåll
refereegranskat (279)
övrigt vetenskapligt/konstnärligt (24)
populärvet., debatt m.m. (1)
Författare/redaktör
Turner, APF (27)
Turner, Anthony (19)
Gorton, Lo (17)
Turner, Anthony P. F ... (17)
Ruzgas, Tautgirdas (15)
Mattiasson, Bo (13)
visa fler...
Tiwari, Ashutosh (12)
Turner, Anthony, 195 ... (11)
Shleev, Sergey (11)
Svedlindh, Peter (9)
Nilsson, Mats (8)
Willander, Magnus (7)
Ramström, Olof (7)
Lundström, Ingemar (7)
Hedström, Martin (7)
Crespo, Gaston A., 1 ... (7)
Strömberg, Mattias (7)
Ludwig, Roland (7)
Csöregi, Elisabeth (7)
Beni, Valerio (7)
Zardán Gómez de la T ... (6)
Lundström, Ingemar, ... (6)
Emnéus, Jenny (6)
Mecklenburg, Michael (5)
Xie, Bin (5)
Lindahl, Tomas, 1954 ... (5)
Dev, Apurba (5)
Mascini, M (5)
Johansson, Christer (4)
Tengvall, Pentti (4)
Schuhmann, Wolfgang (4)
Laurell, Thomas (4)
Liedberg, Bo (4)
Yan, Mingdi (4)
Falk, Magnus (4)
Filippini, Daniel (4)
Schuhmann, W (4)
Aastrup, Teodor (3)
Jager, Edwin (3)
Malmsten, M (3)
Eriksson Karlström, ... (3)
Kriz, Dario (3)
Vagin, Mikhail (3)
Linnros, Jan, 1953- (3)
Bakker, Eric (3)
Höök, Fredrik, 1966 (3)
Christenson, Andreas (3)
Strömme, Maria (3)
Filippini, Daniel, 1 ... (3)
Castillo Leon, Jaime (3)
visa färre...
Lärosäte
Linköpings universitet (139)
Lunds universitet (70)
Kungliga Tekniska Högskolan (34)
Uppsala universitet (29)
Malmö universitet (19)
Chalmers tekniska högskola (11)
visa fler...
Karolinska Institutet (11)
RISE (10)
Göteborgs universitet (9)
Stockholms universitet (7)
Umeå universitet (5)
Linnéuniversitetet (5)
Örebro universitet (1)
Mittuniversitetet (1)
Gymnastik- och idrottshögskolan (1)
Karlstads universitet (1)
visa färre...
Språk
Engelska (303)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (154)
Teknik (45)
Medicin och hälsovetenskap (21)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy