SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "L773:1057 7157 "

Search: L773:1057 7157

  • Result 1-10 of 73
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Antelius, Mikael, et al. (author)
  • Wafer-Level Vacuum Sealing by Coining of Wire Bonded Gold Bumps
  • 2013
  • In: Journal of microelectromechanical systems. - 1057-7157 .- 1941-0158. ; 22:6, s. 1347-1353
  • Journal article (peer-reviewed)abstract
    • This paper reports on the investigation of a novel room-temperature vacuum sealing method based on compressing wire bonded gold bumps which are placed to partially overlap the access ports into the cavity. The bump compression, which is done under vacuum, causes a material flow into the access ports, thereby hermetically sealing a vacuum inside the cavities. The sealed cavity pressure was measured by residual gas analysis to 8x10(-4) mbar two weeks after sealing. The residual gas content was found to be mainly argon, which indicates the source as outgassing inside the cavity and no measurable external leak. The seals are found to be mechanically robust and easily implemented by the use of standard commercial tools and processes.
  •  
2.
  • Asiatici, Mikhail, et al. (author)
  • Through Silicon Vias With Invar Metal Conductor for High-Temperature Applications
  • 2017
  • In: Journal of microelectromechanical systems. - : IEEE Press. - 1057-7157 .- 1941-0158. ; 26:1, s. 158-168
  • Journal article (peer-reviewed)abstract
    • Through silicon vias (TSVs) are key enablers of 3-D integration technologies which, by vertically stacking andinterconnecting multiple chips, achieve higher performances,lower power, and a smaller footprint. Copper is the mostcommonly used conductor to fill TSVs; however, copper hasa high thermal expansion mismatch in relation to the siliconsubstrate. This mismatch results in a large accumulation ofthermomechanical stress when TSVs are exposed to high temperaturesand/or temperature cycles, potentially resulting in devicefailure. In this paper, we demonstrate 300 μm long, 7:1 aspectratio TSVs with Invar as a conductive material. The entireTSV structure can withstand at least 100 thermal cycles from −50 °C to 190 °C and at least 1 h at 365 °C, limited bythe experimental setup. This is possible thanks to matchingcoefficients of thermal expansion of the Invar via conductor andof silicon substrate. This results in thermomechanical stressesthat are one order of magnitude smaller compared to copperTSV structures with identical geometries, according to finiteelement modeling. Our TSV structures are thus a promisingapproach enabling 2.5-D and 3-D integration platforms for hightemperatureand harsh-environment applications.
  •  
3.
  •  
4.
  • Bergkvist, Jonas, et al. (author)
  • Miniaturized flowthrough microdispenser with piezoceramic tripod actuation
  • 2005
  • In: Journal of Microelectromechanical Systems. - 1057-7157. ; 14:1, s. 134-140
  • Journal article (peer-reviewed)abstract
    • In this paper, the further development of a silicon flowthrough microdispenser is described. Previously reported designs of the dispenser used bimorph, and later multilayered, piezoelectric actuator elements for the generation of droplets. The introduction of a multilayered actuator significantly reduced the voltage amplitude needed to dispense droplets. Dispenser properties relevant for chemical analysis systems, e.g., reduced sample volume, internal surface area, and dispersion, were improved by miniaturization of the device. In this paper, a new actuator design, the tripod, is presented to enable further dispenser miniaturization and to facilitate device assembly. Tripod actuators were manufactured using a prototyping process, based on micromilling, for multilayer piezoceramic components. A building technique for miniaturized electrical interconnects, based on microstructured flexible printed circuits, is also suggested in line with the prospect of future miniaturization. The microfluidic properties of the tripod- actuated dispenser were evaluated. Stable droplet generation in the frequency range from 0 to 3 kHz was demonstrated, providing a maximum dispensed flow rate of 7.8 muL/min.
  •  
5.
  • Berglund, Martin, et al. (author)
  • Operation characteristics and optical emission distribution of a miniaturized silicon through-substrate split-ring resonator microplasma source
  • 2014
  • In: Journal of microelectromechanical systems. - 1057-7157 .- 1941-0158. ; 23:6, s. 1340-1345
  • Journal article (peer-reviewed)abstract
    • There are many new microplasma sources being developed for a wide variety of applications, each with different properties tailored to its specific use. Microplasma sources enable portable instruments for, e.g., chemical analysis, sterilization, or activation of substances. A novel microplasma source, based on a microstrip split-ring resonator design with electrodes integrated in its silicon substrate, was designed, manufactured, and evaluated. This device has a plasma discharge gap with a controlled volume and geometry, and offers straightforward integration with other microelectromechancial systems (MEMS) components, e.g., microfluidics. The realized device was resonant at around 2.9 GHz with a quality factor of 18.7. Two different operational modes were observed with the plasma at high pressure being confined in the gap between the electrodes, whereas the plasma at low pressures appeared between the ends of the electrodes on the backside. Measurement of the angular distribution of light emitted from the device with through-substrate electrodes showed narrow emission lobes compared with a reference plasma source with on-substrate electrodes.
  •  
6.
  • Bodén, Roger, et al. (author)
  • Microdispenser with continuous flow and selectable target volume for microfluidic high-pressure applications
  • 2014
  • In: Journal of microelectromechanical systems. - 1057-7157 .- 1941-0158. ; 23:2, s. 452-458
  • Journal article (peer-reviewed)abstract
    • This paper presents a reusable microdispenser intended for continuous flow dispensing of variable and controlled volumes of liquid against high back-pressures. The microdispenser consists of two active valves and a dispenser chamber, all actuated by the volume change associated with the solid-to-liquid phase transition of paraffin wax. It is fabricated using stainless steel sheets, a flexible printed circuit board, and a polyimide membrane. All are covered with Parylene C for insulation and fusion bonding at assembly. A finite element method (FEM) model of the paraffin actuator is used to predict the resulting flow characteristics. The results show dispensing of well-defined volumes of 350 and 540 nL, with a good repeatability between dispensing sequences, as well as reproducibility between devices. In addition, the flow characteristics show no back-pressure dependence of the dispensed flow in the interval 0.5--2.0 MPa. The FEM model can be used to predict the flow characteristics qualitatively
  •  
7.
  • Braun, Stefan, et al. (author)
  • Row/column addressing scheme for large electrostatic actuator MEMS switch arrays and optimization of the operational reliability by statistical analysis
  • 2008
  • In: Journal of microelectromechanical systems. - 1057-7157 .- 1941-0158. ; 17:5, s. 1104-1113
  • Journal article (peer-reviewed)abstract
    • This paper investigates the design and optimization of a row/column addressing scheme to individually pull in or pull out single electrostatic actuators in an N(2) array, utilizing the electromechanical hysteresis behavior of electrostatic actuators and efficiently reducing the number of necessary control lines from N(2) complexity to 2N. This paper illustrates the principle of the row/column addressing scheme. Furthermore, it investigates the optimal addressing voltages to individually pull in or pull out single actuators with maximum operational reliability, determined by the statistical parameters of the pull-in and pull-out characteristics of the actuators. The investigated addressing scheme is implemented for the individual addressing of cross-connect switches in a microelectromechanical systems 20 x 20 switch array, which is utilized for the automated any-to-any interconnection of 20 input signal line pairs to 20 output signal line pairs. The investigated addressing scheme and the presented calculations were successfully tested on electrostatic actuators in a fabricated 20 x 20 array. The actuation voltages and their statistical variations were characterized for different subarray cluster sizes. Finally, the addressing voltages were calculated and verified by tests, resulting in an operational reliability of 99.9498% (502 parts per million (ppm) failure rate) for a 20 x 20 switch array and of 99.99982% (1.75 ppm failure rate) for a 3 x 3 subarray cluster. The array operates by ac-actuation voltage to minimize the disturbing effects by dielectric charging of the actuator isolation layers, as observed in this paper for dc-actuation voltages.
  •  
8.
  • Braun, Stefan, et al. (author)
  • Wafer-Scale Manufacturing of Bulk Shape-Memory-Alloy Microactuators Based on Adhesive Bonding of Titanium-Nickel Sheets to Structured Silicon Wafers
  • 2009
  • In: Journal of microelectromechanical systems. - : Institute of Electrical and Electronics Engineers (IEEE). - 1057-7157 .- 1941-0158. ; 18:6, s. 1309-1317
  • Journal article (peer-reviewed)abstract
    • This paper presents a concept for the wafer-scale manufacturing of microactuators based on the adhesive bonding of bulk shape-memory-alloy (SMA) sheets to silicon microstructures. Wafer-scale integration of a cold-state deformation mechanism is provided by the deposition of stressed films onto the SMA sheet. A concept for heating of the SMA by Joule heating through a resistive heater layer is presented. Critical fabrication issues were investigated, including the cold-state deformation, the bonding scheme and related stresses, and the titanium-nickel (TiNi) sheet patterning. Novel methods for the transfer stamping of adhesive and for the handling of the thin TiNi sheets were developed, based on the use of standard dicing blue tape. First demonstrator TiNi cantilevers, wafer-level adhesively bonded on a microstructured silicon substrate, were successfully fabricated and evaluated. Intrinsically stressed silicon dioxide and silicon nitride were deposited using plasma-enhanced chemical vapor deposition to deform the cantilevers in the cold state. Tip deflections for 2.5-mm-long cantilevers in cold/hot state of 250/70 and 125/28 mu m were obtained using silicon dioxide and silicon nitride, respectively. The bond strength proved to be stronger than the force created by the 2.5-mm-long TiNi cantilever and showed no degradation after more than 700 temperature cycles. The shape-memory behavior of the TiNi is maintained during the integration process.
  •  
9.
  • Briand, D., et al. (author)
  • Low-power micromachined MOSFET gas sensor
  • 2000
  • In: Journal of microelectromechanical systems. - : Institute of Electrical and Electronics Engineers (IEEE). - 1057-7157 .- 1941-0158. ; 9:3, s. 303-308
  • Journal article (peer-reviewed)abstract
    • This paper reports on the design, fabrication, and characterization of the first low-power consumption MOSFET gas sensor. The novel MOSFET array gas sensor has been fabricated using anisotropic bulk silicon micromachining. A heating resistor, a diode used as temperature sensor, and four MOSFETs are located in a silicon island suspended by a dielectric membrane. The membrane has a low thermal conductivity coefficient and, therefore, thermally isolates the electronic components from the chip frame. This low thermal mass device allows the reduction of the power consumption to a value of 90 mW for an array of four MOSFETs at an operating temperature of 170 °C. Three of the MOSFETs have their gate covered with thin catalytic metals and are used as gas sensors. The fourth one has a standard gate covered with nitride and could act as a reference. The sensor was tested under different gaseous atmospheres and has shown good gas sensitivities to hydrogen and ammonia. The low-power MOSFET array gas sensor presented is suitable for applications in portable gas sensor instruments, electronic noses, and automobiles.
  •  
10.
  • Carlborg, Carl Fredrik, et al. (author)
  • A High-Yield Process for 3-D Large-Scale Integrated Microfluidic Networks in PDMS
  • 2010
  • In: Journal of microelectromechanical systems. - 1057-7157 .- 1941-0158. ; 19:5, s. 1050-1057
  • Journal article (peer-reviewed)abstract
    • This paper presents an uncomplicated high-yield fabrication process for creating large-scale integrated (LSI) 3-D microfluidic networks in poly(dimethylsiloxane) (PDMS). The key innovation lays in the robust definition of miniaturized out-of-plane fluidic interconnecting channels (=vias) between stacked layers of microfluidic channels in standard PDMS. Unblocked vias are essential for creating 3-D microfluidic networks. Previous methods either suffered from limited yield in achieving unblocked vias due to residual membranes obstructing the vias after polymerization, or required complicated and/or manual procedures to remove the blocking membranes. In contrast, our method prevents the formation of residual membranes by inhibiting the PDMS polymerization on top of the mold features that define the vias. In addition to providing unblocked vias, the inhibition process also leaves a partially cured, sticky flat-top surface that adheres well to other surfaces and that allows self-sealing stacking of several PDMS layers. We demonstrate the new method by manufacturing a densely perforated PDMS membrane and an LSI 3-D PDMS microfluidic channel network. We also characterize the inhibition mechanism and study the critical process parameters. We demonstrate that the method is suitable for structuring PDMS layers with a thickness down to 10 mu m.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 73
Type of publication
journal article (72)
patent (1)
Type of content
peer-reviewed (71)
other academic/artistic (1)
pop. science, debate, etc. (1)
Author/Editor
Stemme, Göran (36)
Niklaus, Frank (12)
Oberhammer, Joachim (9)
Roxhed, Niclas (7)
Hjort, Klas (6)
van der Wijngaart, W ... (6)
show more...
Enoksson, Peter, 195 ... (5)
Bodén, Roger (5)
Haasl, Sjoerd (5)
Stemme, Göran, 1958 (3)
Nilsson, Johan (2)
Laurell, Thomas (2)
Hjort, Klas, 1964- (2)
Svensson, Krister (2)
Rahiminejad, Sofia, ... (2)
Karlen, D. (2)
Enoksson, P. (2)
Klintberg, Lena (2)
Ogden, Sam (2)
Antelius, Mikael (2)
Lapisa, Martin (2)
Gupta, R. (1)
Abbasi, Morteza, 198 ... (1)
Ghorbani, Morteza (1)
Olin, Håkan (1)
Ollmar, Stig (1)
Fischer, Andreas (1)
Löfdahl, Lennart, 19 ... (1)
Lundström, Ingemar (1)
Johansson, S (1)
Nilsson, Bengt, 1954 (1)
Persson, Anders (1)
Svensson, Krister, 1 ... (1)
Rusu, Cristina (1)
Sterner, Mikael (1)
Johansson, Stefan (1)
Vassilev, Vessen, 19 ... (1)
Amberg, Gustav (1)
Pucci, Elena, 1982 (1)
Kildal, Per-Simon, 1 ... (1)
Lilliehorn, T (1)
Lilliehorn, Tobias (1)
Oberhammer, Joachim, ... (1)
Griss, P. (1)
Olin, Håkan, 1957- (1)
Cheng, Shi (1)
Yantchev, Ventsislav (1)
Fischer, Andreas C., ... (1)
Fischer, Andreas C. (1)
Edqvist, Erik (1)
show less...
University
Royal Institute of Technology (44)
Uppsala University (18)
Chalmers University of Technology (6)
Karlstad University (3)
Linköping University (2)
Mid Sweden University (2)
show more...
RISE (2)
Karolinska Institutet (2)
Umeå University (1)
Lund University (1)
Södertörn University (1)
Swedish National Defence College (1)
show less...
Language
English (72)
Undefined language (1)
Research subject (UKÄ/SCB)
Engineering and Technology (41)
Natural sciences (7)
Medical and Health Sciences (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view