SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1074 6218 "

Sökning: L773:1074 6218

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ivancev, Krassi, et al. (författare)
  • Abdominal aortic aneurysms: experience with the Ivancev-Malmo endovascular system for aortomonoiliac stent-grafts
  • 1997
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 4:3, s. 242-251
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To describe a component-based aortomonoiliac stent-graft system and the first clinical results achieved with this device in endovascular abdominal aortic aneurysm (AAA) repair. METHODS: From November 1993 to October 1996, 45 patients aged 60 to 86 years underwent endoluminal exclusion of true AAAs (median diameter 60 mm) involving the common iliac arteries (median diameter 16 mm right and 15 mm left) using unilimb stent-grafts deployed with the Iancev-Malmo system. RESULTS: Six immediate conversions occurred in the beginning of the series due to endografts that were too short. Complications, including 2 inadvertent renal artery occlusions, 7 kinked grafts, 6 iliac artery dissections, and 3 perioccluder leaks, were prominent features in the first 15 patients. Five patients died in the postoperative period, four of whom were nonsurgical candidates. There were five significant stent-graft migrations: one 3 weeks after surgery due to mechanical injury of the proximal stent and four after 1 year owing to continuous dilation of a wide proximal neck, stent-graft placement in a conical, thrombus-lined proximal neck, and two instances of proximal extension separation from the main graft. Translumbar aneurysm perfusion required embolization in 3 patients. CONCLUSIONS: Despite early complications associated with a learning curve, exclusion of large AAAs using unilimb stent-grafts is feasible. Strict inclusion criteria are necessary in order to improve mortality among nonsurgical candidates and minimize the risk for late migration.
  •  
2.
  • Lindh, Mats, et al. (författare)
  • Endovascular stent-anchored aortic grafts: a comparison between self-expanding and balloon-expandable stents in minipigs
  • 1996
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 3:3, s. 284-289
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To study endovascular graft attachment with self-expanding Gianturco Z-stents and balloon-expanded Palmaz stents and the effect of these devices on the renal ostia. METHODS: Ten stent-grafts were constructed, 5 with Gianturco Z-stents and 5 with Palmaz stents. The endografts were implanted under fluoroscopic guidance into the abdominal aorta of 10 pigs so that the uncovered portion of the proximal stent extended over the renal artery orifices. Distal aortic blood pressure and flow were measured before and after graft placement and 1 hour postprocedure. The aorta was then exposed surgically, and the central portion of the stent-graft was inspected through an aortotomy to assess perigraft leakage. RESULTS: Stent-graft implantation was accurate and hemostatic in all cases, despite longitudinal folding of the graft due to oversizing. However, transverse folds produced pressure gradients (> 15 mmHg) between the ends of the graft in two cases. In another case, a pressure gradient resulted from partial thrombosis of the graft. In two cases, renal artery occlusion and thrombosis occurred due to coverage by the graft material. In two other animals, one of the renal arteries was entirely uncovered by a stent. The remaining 16 renal arteries were covered by the proximal stent but not the graft, as intended. One (6.25%) of these arteries thrombosed, but the remainder were grossly patent when the animals were sacrificed at 1 hour. CONCLUSIONS: Both Palmaz and Gianturco Z-stents produced hemostatic endovascular graft attachment, even in the presence of moderate graft oversizing. The risk of acute renal artery occlusion from juxtarenal stenting does not appear to be prohibitive, but longer term observations are needed.
  •  
3.
  • Malina, Martin, et al. (författare)
  • Changing aneurysmal morphology after endovascular grafting: relation to leakage or persistent perfusion
  • 1997
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 4:1, s. 23-30
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To relate changing abdominal aortic aneurysm (AAA) morphology after endovascular grafting to the presence of leakage, collateral perfusion, and other factors. METHODS: Thirty-five patients who underwent successful AAA endovascular grafting were evaluated. Self-expanding Z-stents and Dacron grafts were applied in bifurcated and aortomonoiliac systems. Postoperative diameter changes were calculated from repeated spiral computed tomographic scans, angiograms, and ultrasonic phase-locked echo-tracking scans during a median 6-month follow-up (interquartile range [IQR] 3 to 12). RESULTS: At 12 months, the diameters of completely excluded aneurysms had decreased 6 mm (IQR 2 to 11; p = 0.006). The proximal graft-anchoring stents had dilated 2 mm (IQR 0.5 to 3.3; p = 0.01). The aortic diameters immediately below the renal arteries but above the stents had not changed. Endoleakage and collateral perfusion (n = 13) were each associated with preserved aneurysm size and a 12 times higher risk of aneurysm dilation. After the leakage or the collateral perfusion had been treated, the aneurysm size decreased. Aneurysms with extensive intraluminal thrombi presented a reduced risk of leakage or perfusion. CONCLUSIONS: The diameters of endovascularly excluded AAAs decrease, except in cases of leakage or perfusion. Careful follow-up of patients with aortic endografts is necessary.
  •  
4.
  • Malina, Martin, et al. (författare)
  • Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?
  • 1998
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 5:4, s. 310-317
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. METHODS: Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. RESULTS: The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p < 0.001. Both hooks and barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. CONCLUSIONS: Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.
  •  
5.
  • Malina, Martin, et al. (författare)
  • Late aortic arch perforation by graft-anchoring stent: complication of endovascular thoracic aneurysm exclusion
  • 1998
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 5:3, s. 274-277
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To describe a fatal case of late aortic perforation by an endograft-anchoring stent. METHODS AND RESULTS: A 69-year-old woman presented 2 years after thoracoabdominal aneurysm repair with a 9-cm dilatation of the descending thoracic aorta proximal to the conventional aortic graft. A 38-mm Dacron graft with multiple Gianturco Z-stents sutured inside was placed transluminally across the aortic arch such that part of the uncovered portion of the proximal stent was partially across the left subclavian orifice. Four months later, the patient died from massive hemorrhage. Autopsy showed that the uncovered portion of the proximal stent had perforated the aortic arch. CONCLUSIONS: This case stresses the need for low-profile stent-grafts and smaller, more flexible introducer systems. Anchoring stents must be flexible, less traumatic, and strong enough to create a watertight seal even in tortuous vessels. To avoid aortic arch damage by thoracic stent-grafts, the proximal stent should be fully covered by the fabric.
  •  
6.
  • Norgren, L, et al. (författare)
  • Aortoenteric fistula caused by a ruptured stent-graft: a case report
  • 1998
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 5:3, s. 269-272
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To report a case of aortoenteric fistula secondary to endovascular abdominal aortic aneurysm (AAA) exclusion using the Stentor bifurcated endovascular graft. METHODS AND RESULTS: Seventeen months after a successful endovascular AAA procedure, a male patient developed upper gastrointestinal bleeding. An aortoenteric fistula was diagnosed. At operation, the endograft fabric was found to be ruptured in an area of suture disruption between the nitinol stents. Coincidentally, a pre-existing inflammatory process might have caused adhesions between the bowel and the aortic wall, predisposing to fistula formation. The patient recovered after placement of a conventional aortic graft. CONCLUSIONS: Suture disruption between the internal support stents is a recognized complication in the first-generation Stentor device. Although the case described here is probably not typical of the consequences of this sequela, it does reinforce the need for continual periodic imaging to check for signs of graft disruption in Stentor endografts.
  •  
7.
  • Resch, Tim, et al. (författare)
  • Abdominal aortic aneurysm morphology in candidates for endovascular repair evaluated with spiral computed tomography and digital subtraction angiography
  • 1999
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 6:3, s. 227-232
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To analyze the morphology of abdominal aortic aneurysms (AAAs) and to study the usefulness of spiral computed tomography (CT) versus digital subtraction angiography (DSA) in the evaluation of patients for endovascular repair. METHODS: Of 133 AAA patients (120 men, mean age 67 years, range 52 to 84) evaluated preoperatively with CT imaging, 77 endograft candidates (68 men) were also assessed with intra-arterial DSA. Arterial parameters were measured on axial CT scans and angiographic films for comparison. RESULTS: Mean maximum AAA diameter was 58 +/- 11 mm (range 39 to 95). Aneurysmal neck diameter was consistently smaller on DSA than on CT (20.7 +/- 3.6 mm versus 23.0 +/ 3.5 mm, p < 0.0001). The distance from the most distal renal artery to the aortic bifurcation was longer on angiography than on CT (mean difference 10.0 mm, p < 0.0001). There was a positive correlation between the maximum AAA diameter and the AAA length (r = 0.49, p < 0.0001) and an inverse relationship between the neck length and the neck diameter (r = -0.36, p < 0.0001). No correlation was found between the maximum AAA diameter and maximum iliac diameter, angulation, or length. CONCLUSIONS: AAA anatomy varies widely and independently of the aneurysm size. Therefore, the maximum size of the aneurysm is a poor predictor of whether or not an aneurysm is suitable for endovascular repair. The discrepancy between angiographic and axial CT measurements suggests that neither alone is sufficient as a preoperative imaging technique when evaluating a patient for an endovascular graft procedure.
  •  
8.
  • Sonesson, Björn, et al. (författare)
  • Dilatation of the infrarenal aneurysm neck after endovascular exclusion of abdominal aortic aneurysm
  • 1998
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 5:3, s. 195-200
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To determine the fate of the infrarenal aneurysm neck and suprarenal aorta after endovascular exclusion of abdominal aortic aneurysms (AAAs). METHODS: Thirty-four patients underwent endovascular AAA repair between January 1994 and December 1995 using custom-made stent-grafts constructed from polyester graft material and modified self-expanding Gianturco Z-stents sutured to the graft orifices. Thirty-one patients were available for follow-up. Pre- and postimplantation diameters were measured using spiral computed tomography in the infrarenal aneurysm neck and the suprarenal aorta at the level of the superior mesenteric artery (SMA). RESULTS: The mean follow-up time was 25 months. There was a significant increase of the diameter of the infrarenal aneurysm neck (+ 1.65 mm, p = 0.002), but not in the aorta at the level of the SMA (+0.52 mm, p = 0.100). There was no difference in the change in diameter in the infrarenal neck in the group with a stent adjacent to the level of measurement (n = 20) compared with the group without an adjacent stent (n = 11, p = 0.790). There was no correlation between preimplantation size of the infrarenal neck and its diameter change (r = 0.14, p = 0.488). There was no correlation (r = 0.10, p = 0.603) or association (chi-square test, p = 0.211) between aortic diameter change at the level of the SMA and the infrarenal neck. CONCLUSIONS: This investigation shows a significant dilatation of the infrarenal aneurysm neck, but not in the suprarenal aorta, after endovascular AAA repair with this device. The clinical significance of these findings is unclear. Whether such a dilatation in the infrarenal aneurysm neck may affect the long-term attachment of stent-grafts remains to be shown in the future.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy