SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1475 925X "

Sökning: L773:1475 925X

  • Resultat 1-10 av 28
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Antfolk, Christian, et al. (författare)
  • Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system
  • 2010
  • Ingår i: BioMedical Engineering Online. - 1475-925X. ; 9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The users of today's commercial prosthetic hands are not given any conscious sensory feedback. To overcome this deficiency in prosthetic hands we have recently proposed a sensory feedback system utilising a "tactile display" on the remaining amputation residual limb acting as man-machine interface. Our system uses the recorded pressure in a hand prosthesis and feeds back this pressure onto the forearm skin. Here we describe the design and technical solution of the sensory feedback system aimed at hand prostheses for trans-radial/humeral amputees. Critical parameters for the sensory feedback system were investigated. Methods: A sensory feedback system consisting of five actuators, control electronics and a test application running on a computer has been designed and built. Firstly, we investigate which force levels were applied to the forearm skin of the user while operating the sensory feedback system. Secondly, we study if the proposed system could be used together with a myoelectric control system. The displacement of the skin caused by the sensory feedback system would generate artefacts in the recorded myoelectric signals. Accordingly, EMG recordings were performed and an analysis of the these are included. The sensory feedback system was also preliminarily evaluated in a laboratory setting on two healthy non-amputated test subjects with a computer generating the stimuli, with regards to spatial resolution and force discrimination. Results: We showed that the sensory feedback system generated approximately proportional force to the angle of control. The system can be used together with a myoelectric system as the artefacts, generated by the actuators, were easily removed using a simple filter. Furthermore, the application of the system on two test subjects showed that they were able to discriminate tactile sensation with regards to spatial resolution and level of force. Conclusions: The results of these initial experiments in non-amputees indicate that the proposed tactile display, in its simple form, can be used to relocate tactile input from an artificial hand to the forearm and that the system can coexist with a myoelectric control systems. The proposed system may be a valuable addition to users of myoelectric prosthesis providing conscious sensory feedback during manipulation of objects.
  •  
2.
  • Axner, Lilit, et al. (författare)
  • Simulations of time harmonic blood flow in the Mesenteric artery: comparing finite element and lattice Boltzmann methods
  • 2009
  • Ingår i: Biomedical engineering online. - 1475-925X. ; 8:23, s. 28-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Systolic blood flow has been simulated in the abdominal aorta and the superior mesenteric artery. The simulations were carried out using two different computational hemodynamic methods: the finite element method to solve the Navier Stokes equations and the lattice Boltzmann method. Results: We have validated the lattice Boltzmann method for systolic flows by comparing the velocity and pressure profiles of simulated blood flow between methods. We have also analyzed flow-specific characteristics such as the formation of a vortex at curvatures and traces of flow. Conclusion: The lattice Boltzmann Method is as accurate as a Navier Stokes solver for computing complex blood flows. As such it is a good alternative for computational hemodynamics, certainly in situation where coupling to other models is required.
  •  
3.
  • Broomé, Michael, et al. (författare)
  • Closed-loop real-time simulation model of hemodynamics and oxygen transport in the cardiovascular system
  • 2013
  • Ingår i: Biomedical engineering online. - 1475-925X. ; 12:1, s. 69-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Computer technology enables realistic simulation of cardiovascular physiology. The increasing number of clinical surgical and medical treatment options imposes a need for better understanding of patient-specific pathology and outcome prediction. Methods: A distributed lumped parameter real-time closed-loop model with 26 vascular segments, cardiac modelling with time-varying elastance functions and gradually opening and closing valves, the pericardium, intrathoracic pressure, the atrial and ventricular septum, various pathological states and including oxygen transport has been developed. Results: Model output is pressure, volume, flow and oxygen saturation from every cardiac and vascular compartment. The model produces relevant clinical output and validation of quantitative data in normal physiology and qualitative directions in simulation of pathological states show good agreement with published data. Conclusion: The results show that it is possible to build a clinically relevant real-time computer simulation model of the normal adult cardiovascular system. It is suggested that understanding qualitative interaction between physiological parameters in health and disease may be improved by using the model, although further model development and validation is needed for quantitative patient-specific outcome prediction.
  •  
4.
  • Ekstrand, Vilhelm, et al. (författare)
  • Influence of electrical and thermal properties on RF ablation of breast cancer: is the tumour preferentially heated?
  • 2005
  • Ingår i: Biomedical engineering online. - 1475-925X. ; 4, s. 41-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Techniques based on radio frequency (RF) energy have many applications in medicine, in particular tumour ablation. Today, mammography screening detects many breast cancers at an early stage, facilitating treatment by minimally invasive techniques such as radio frequency ablation (RFA). The breast cancer is mostly surrounded by fat, which during RFA-treatment could result in preferential heating of the tumour due to the substantial differences in electrical parameters. The object of this study was to investigate if this preferential heating existed during experimental in vitro protocols and during computer simulations. Methods: Excised breast material from four patients with morphologically diagnosed breast cancers were treated with our newly developed RFA equipment. Subsequently, two finite element method (FEM) models were developed; one with only fat and one with fat and an incorporated breast cancer of varying size. The FEM models were solved using temperature dependent electrical conductivity versus constant conductivity, and transient versus steady-state analyses. Results: Our experimental study performed on excised breast tissue showed a preferential heating of the tumour, even if associated with long tumour strands. The fat between these tumour strands was surprisingly unaffected. Furthermore, the computer simulations demonstrated that the difference in electrical and thermal parameters between fat and tumour tissue can cause preferential heating of the tumour. The specific absorption rate (SAR) distribution changed significantly when a tumour was present in fatty tissue. The degree of preferential heating depended on tissue properties, tumour shape, and placement relative to the electrode. Temperature dependent electrical conductivity increased the thermal lesion volume, but did not change the preferential heating. Transient solutions decreased the thermal lesion volume but increased the preferential heating of the tumour. Conclusions: Both the computer model and the in vitro study confirmed that preferential heating of the tumour during RFA exists in breast tissue. However, the observed preferential heating in the in vitro studies were more pronounced, indicating that additional effects other than the difference in tissue parameters might be involved. The existing septa layers between the cancer tissue and the fatty tissue could have an additional electrical or thermal insulating effect, explaining the discrepancy between the in vitro study and the computer model.
  •  
5.
  • Grönlund, Christer, et al. (författare)
  • Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging
  • 2013
  • Ingår i: Biomedical engineering online. - : BioMed Central (BMC). - 1475-925X. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Ultrasound imaging of the heart is a commonly used clinical tool to assess cardiac function. The basis for this analysis is the quantification of cardiac blood flow and myocardial velocities. These are typically measured using different imaging modes and on different cardiac cycles. However, due to beat-to-beat variations such as irregular heart rhythm and transient events, simultaneous acquisition is preferred. There exists specialized ultrasound systems for this purpose; however, it would be beneficial if this could be achieved using conventional ultrasound systems due to their wide availability. The conventional Duplex mode ultrasound allows simultaneous acquisition, however at a highly reduced spatial and temporal resolution.METHODS: The aim of this work was to present and evaluate the performance of a novel method to recover myocardial tissue velocity using conventional Duplex ultrasound imaging, and to demonstrate its feasibility for the assessment of simultaneous blood flow and myocardial velocity in-vivo. The essence of the method was the estimation of the axial phase shift of robust echogenic structures between subsequent image frames. The performance of the method was evaluated on synthetic tissue mimicking B-mode image sequences at different frame rates (20--60 Hz) and tissue velocities (peak velocities 5-15cm/s), using cardiac deformation and displacement characteristics. The performance was also compared to a standard 2-D speckle tracking technique.RESULTS: The method had an overall high performance at frame rates above 25 Hz, with less than 15% error of the peak diastolic velocity, and less than 10 ms peak timing error. The method showed superior performance compared to the 2-D tracking technique at frame rates below 50 Hz. The in-vivo quantification of simultaneous blood flow and myocardial tissue velocities verified the echocardiographic patterns and features of healthy subjects and the specific patient group.CONCLUSIONS: A novel myocardial velocity quantification method was presented and high performance at frame rates above 25Hz was shown. In-vivo quantification of simultaneous myocardial and blood flow velocities was feasible using the proposed method and conventional Duplex mode imaging. We propose that the methodology is suitable for retrospective as well as prospective studies on the mechanics and hemodynamics of the heart.
  •  
6.
  •  
7.
  • Karlsson, Marcus, et al. (författare)
  • Automatic filtering of outliers in RR intervals before analysis of heart rate variability in Holter recordings : a comparison with carefully edited data.
  • 2012
  • Ingår i: Biomedical engineering online. - 1475-925X. ; 11:2, s. 12-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Undetected arrhythmic beats seriously affect the power spectrum of the heart rate variability (HRV). Therefore, the series of RR intervals are normally carefully edited before HRV is analysed, but this is a time consuming procedure when 24-hours recordings are analysed. Alternatively, different methods can be used for automatic removal of arrhythmic beats and artefacts. This study compared common frequency domain indices of HRV when determined from manually edited and automatically filtered RR intervals.Methods and Results: Twenty-four hours Holter recordings were available from 140 healthy subjects of age 1-75 years. An experienced technician carefully edited all recordings. Automatic filtering was performed using a recursive procedure where RR intervals were removed if they differed from the mean of the surrounding RR intervals with more than a predetermined limit (ranging from 10% to 50%). The filtering algorithm was evaluated by replacing 1% of the beats with synthesised ectopic beats. Power spectral analysis was performed before and after filtering of both the original edited data and the noisy data set. The results from the analysis using the noisy data were used to define an age-based filtering threshold. The age-based filtration was evaluated with completely unedited data, generated by removing all annotations from the series of RR intervals, and then comparing the resulting HRV indices with those obtained using edited data. The results showed equivalent results after age-based filtration of both the edited and unedited data sets, where the differences in HRV indices obtained by different preprocessing methods were small compared to the mean values within each age group.Conclusions: The study showed that it might not be necessary to perform the time-consuming careful editing of all detected heartbeats before HRV is analysed in Holter recordings.In most subjects, it is sufficient to perform the regular editing needed for valid arrhythmia analyses, and then remove undetected ectopic beats and artefacts by age-based filtration of the series of RR intervals, particularly in subjects older than 30 years.
  •  
8.
  •  
9.
  • Ortiz Catalan, Max Jair, 1982, et al. (författare)
  • On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion
  • 2012
  • Ingår i: BioMedical Engineering OnLine. - 1475-925X. ; 11:33
  • Tidskriftsartikel (refereegranskat)abstract
    • The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface electrodes and their highly environmental dependency. This paper describes several implantable electrodes and discusses them as a solution for the natural control of artificial limbs. In this context "natural" is defined as producing control over limb movement analogous to that of an intact physiological system. This includes coordinated and simultaneous movements of different degrees of freedom. It also implies that the input signals must come from nerves or muscles that were originally meant to produce the intended movement and that feedback is perceived as originating in the missing limb without requiring burdensome levels of concentration. After scrutinizing different electrode designs and their clinical implementation, we concluded that the epimysial and cuff electrodes are currently promising candidates to achieving a long-term stable and natural control of robotic prosthetics, provided that communication from the electrodes to the outside of the body is guaranteed.
  •  
10.
  • Peixoto, Helton M., et al. (författare)
  • Automatic tracking of cells for video microscopy in patch clamp experiments
  • 2014
  • Ingår i: Biomedical engineering online. - 1475-925X. ; 13, s. 78-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Visualisation of neurons labeled with fluorescent proteins or compounds generally require exposure to intense light for a relatively long period of time, often leading to bleaching of the fluorescent probe and photodamage of the tissue. Here we created a technique to drastically shorten light exposure and improve the targeting of fluorescent labeled cells that is specially useful for patch-clamp recordings. We applied image tracking and mask overlay to reduce the time of fluorescence exposure and minimise mistakes when identifying neurons. Methods: Neurons are first identified according to visual criteria (e.g. fluorescence protein expression, shape, viability etc.) and a transmission microscopy image Differential Interference Contrast (DIC) or Dodt contrast containing the cell used as a reference for the tracking algorithm. A fluorescence image can also be acquired later to be used as a mask (that can be overlaid on the target during live transmission video). As patch-clamp experiments require translating the microscope stage, we used pattern matching to track reference neurons in order to move the fluorescence mask to match the new position of the objective in relation to the sample. For the image processing we used the Open Source Computer Vision (OpenCV) library, including the Speeded-Up Robust Features (SURF) for tracking cells. The dataset of images (n = 720) was analyzed under normal conditions of acquisition and with influence of noise (defocusing and brightness). Results: We validated the method in dissociated neuronal cultures and fresh brain slices expressing Enhanced Yellow Fluorescent Protein (eYFP) or Tandem Dimer Tomato (tdTomato) proteins, which considerably decreased the exposure to fluorescence excitation, thereby minimising photodamage. We also show that the neuron tracking can be used in differential interference contrast or Dodt contrast microscopy. Conclusion: The techniques of digital image processing used in this work are an important addition to the set of microscopy tools used in modern electrophysiology, specially in experiments with neuron cultures and brain slices.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 28
Typ av publikation
tidskriftsartikel (27)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (28)
Författare/redaktör
Ahlström, Håkan, 195 ... (2)
Jönsson, Hanna (2)
Kullberg, Joel, 1979 ... (2)
Grönlund, Christer (2)
Rohlén, Robin (2)
Braunschweig, F (1)
visa fler...
Hovatta, O (1)
Stahlberg, M. (1)
Ortiz Catalan, Max J ... (1)
Rydberg, Annika (1)
Henein, Michael Y. (1)
Wang, Xin (1)
Norberg, Petronella (1)
Nilsson, David (1)
Wiklund, Urban (1)
Dalal, Koustuv, Prof ... (1)
Wang, Fei (1)
Linde, C (1)
Hansson, S (1)
Lundborg, Göran (1)
Hoekstra, Alfons G. (1)
Janerot-Sjöberg, Bir ... (1)
Wessberg, Johan, 196 ... (1)
Lindqvist, Per (1)
Nyberg, Lars (1)
Weigl, Wojciech (1)
Bennett, T (1)
Ander, Mats, 1964 (1)
Rosén, Birgitta (1)
Skottman, H (1)
Gasser, T. Christian (1)
Ask, Per (1)
Strand, Robin, 1978- (1)
Ahmad, Nouman (1)
Tarai, Sambit (1)
Lundström, Elin (1)
Dahlberg, Hugo (1)
Guggilla, Rama Krish ... (1)
Bergstrom, Goran (1)
Eriksson, Anders, 19 ... (1)
Chen, Yuting (1)
Xu, Linghui (1)
Björefors, Fredrik (1)
Jakola, Asgeir Store (1)
Rotstein, S (1)
Karlsson, Marcus (1)
Hörnsten, Rolf (1)
Gustafsson, Thomas (1)
Ali, Hazrat (1)
Umander, Johannes (1)
visa färre...
Lärosäte
Umeå universitet (5)
Kungliga Tekniska Högskolan (5)
Karolinska Institutet (5)
Göteborgs universitet (4)
Uppsala universitet (4)
Linköpings universitet (4)
visa fler...
Chalmers tekniska högskola (4)
Lunds universitet (3)
Luleå tekniska universitet (2)
Jönköping University (1)
Malmö universitet (1)
Mittuniversitetet (1)
RISE (1)
visa färre...
Språk
Engelska (28)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (18)
Teknik (13)
Naturvetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy