1.
  • Abdollahi, Sara, et al. (författare)
  • Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy : implementation and first clinical experience in Iran
  • 2022
  • Ingår i: Reports of Practical Oncology and Radiotherapy. - 1507-1367. ; 27:5, s. 881-896
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung dose reduction approach for left-sided breast cancer irradiation. Materials and methods: Accuracy and reproducibility of the optical surface scanner used for DIBH treatment were evaluated using different phantoms. Patient positioning accuracy and reproducibility of DIBH treatment were evaluated. Twenty patients were studied for treatment plan quality in target dose coverage and healthy organ sparing for the two different treatment techniques. Results: Reproducibility tests for the surface scanner showed good stability within 1 mm in all directions. The maximum position variation between applied shifts on the couch and the scanner measured offsets is 1 mm in all directions. The clinical study of 200 fractions showed good agreement between the surface scanner and portal imaging with the isocenter position deviation of less than 3 mm in each lateral, longitudinal, and vertical direction. The standard deviation of the DIBH level showed a value of < 2 mm during all evaluated DIBHs. Compared to the free breathing (FB) technique, DIBH showed significant reduction of 48% for heart mean dose, 43% for heart V25, and 20% for ipsilateral lung V20. Conclusion: Surface-guided radiotherapy can be regarded as an accurate tool for patient positioning and monitoring in breast radiotherapy. DIBH treatment are considered to be effective techniques in heart and ipsilateral lung dose reductions for left breast radiotherapy.
  •  
2.
  • Bartnikowska, Agnieszka, et al. (författare)
  • Comparison of pre-treatment and in-vivo dosimetry for advanced radiotherapy of prostate cancer
  • 2022
  • Ingår i: Reports of Practical Oncology and Radiotherapy. - : Elsevier. - 1507-1367 .- 2083-4640. ; 27:2, s. 189-197
  • Tidskriftsartikel (refereegranskat)abstract
    • The usage of advanced radiotherapy techniques requires validation of a previously calculated dose with the precise delivery with a linear accelerator. This study aimed to review and evaluate new verification methods of dose distribution. Moreover, our purpose was to define an internal protocol of acceptance for in-vivo measurements of dose distribution. This study included 43 treatment plans of prostate cancer calculated using the Monte Carlo algorithm. all plans were delivered using the Volumetric Modulated arc Therapy (VMaT) technique of advanced radiotherapy by the linear accelerator elekta VersahD. The dose distribution was verified using: MatriXX, iViewDose, and in-vivo measurements. The verification also included recalculation of fluence maps of quality assurance plans in another independent algorithm. The acceptance criterion of 95% points of dose in agreement was found for pre-treatment verification using MatriXX; the average γ value was 99.09 ± 0.93 (sD) and 99.64 ± 0.35 (sD) for recalculation in the collapse cone algorithm. Moreover, using the second algorithm in the verification process showed a positive correlation ρ = 0.58, p < 0.001. however, verification using iViewDose in a phantom and in-vivo did not meet this γ-pass rate.Evaluation of gamma values for in-vivo measurements utilizing iViewDose software was helpful to establish an internal dosimetry protocol for prostate cancer treatments. We assumed value at a minimum of 50% points of the dose in agreement with the 3%/3 mm criterion as an acceptable compliance level. The recalculated dose distribution of Qa plans in regard to the collapse cone algorithm in the other treatment planning system can be used as a pre-treatment verification method used by a medical physicist in their daily work. The effectiveness of use in iViewDose software, as a pre-treatment tool, is still debatable, unlike the MatriXX device.
  •  
3.
  •  
4.
  • Gunnarsson, Kerstin, et al. (författare)
  • Stereotactic radiotherapy for brain metastases in patients with lung cancer; outcome and toxicity in clinical practice.
  • 2022
  • Ingår i: Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. - 1507-1367. ; 27:3, s. 410-418
  • Tidskriftsartikel (refereegranskat)abstract
    • Stereotactic radiotherapy (SRT) is an established modality for treating limited brain metastases (BMs). This study aimed to assess the real-life treatment outcome and associated prognostic factors for survival in a consecutive lung cancer cohort receiving SRT for BMs.A retrospective review and analysis of patients with lung cancer with BMs treated with SRT in western Sweden between 2002 and 2017 were performed. Data were collected from patient charts and the radiotherapy dose planning system.One hundred nine patients corresponding to 139 lesions were assessed; the majority were treated with single-fractionated SRT with 20 Gy. The median overall survival (OS) was 6.1 months, with a 12-month survival rate of 24%. The estimated overall disease control rate (DCR) was 84% at a median time of three months. On multivariate analysis, WHO performance status (PS) (p = 0.002) and smoking status (p = 0.005) were significant predictive factors for survival. Four percent of the patients experienced possible grade III-IV toxicity, and previously administered cranial radiation therapy was a significant independent factor (p = 0.03) associated with the risk of developing acute toxicity.SRT due to brain metastases from lung cancer is a well-tolerated treatment. When selecting patients suitable for treatment, PS and extracranial disease progression should be considered. Smoking cessation is probably of value even in this palliative setting. The goal of SRT for BMs is not only to improve survival but also to provide symptom relief, and future studies on SRT should assess patient-reported outcomes in addition to survival.
  •  