SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1543 2165 "

Sökning: L773:1543 2165

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Clarke, Emily L., et al. (författare)
  • Development and Evaluation of a Novel Point-of-Use Quality Assurance Tool for Digital Pathology
  • 2019
  • Ingår i: Archives of Pathology & Laboratory Medicine. - : COLL AMER PATHOLOGISTS. - 0003-9985 .- 1543-2165. ; 143:10, s. 1246-1255
  • Tidskriftsartikel (refereegranskat)abstract
    • Context.-Flexible working at diverse or remote sites is a major advantage when reporting using digital pathology, but currently there is no method to validate the clinical diagnostic setting within digital microscopy. Objective.-To develop a preliminary Point-of-Use Quality Assurance (POUQA) tool designed specifically to validate the diagnostic setting for digital microscopy. Design.-We based the POUQA tool on the red, green, and blue (RGB) values of hematoxylin-eosin. The tool used 144 hematoxylin-eosin-colored, 5x5-cm patches with a superimposed random letter with subtly lighter RGB values from the background color, with differing levels of difficulty. We performed an initial evaluation across 3 phases within 2 pathology departments: 1 in the United Kingdom and 1 in Sweden. Results.-In total, 53 experiments were conducted across all phases resulting in 7632 test images viewed in all. Results indicated that the display, the users visual system, and the environment each independently impacted performance. Performance was improved with reduction in natural light and through use of medical-grade displays. Conclusions.-The use of a POUQA tool for digital microscopy is essential to afford flexible working while ensuring patient safety. The color-contrast test provides a standardized method of comparing diagnostic settings for digital microscopy. With further planned development, the color-contrast test may be used to create a "Verified Login" for diagnostic setting validation.
  •  
4.
  •  
5.
  •  
6.
  • Elfving, Hedvig, et al. (författare)
  • Tumor Heterogeneity Confounds Lymphocyte Metrics in Diagnostic Lung Cancer Biopsies
  • 2024
  • Ingår i: Archives of Pathology & Laboratory Medicine. - : Archives of Pathology and Laboratory Medicine. - 0003-9985 .- 1543-2165. ; 148:1, s. e18-e24
  • Tidskriftsartikel (refereegranskat)abstract
    • Context.—The immune microenvironment is involved in fundamental aspects of tumorigenesis, and immune scores are now being developed for clinical diagnostics. Objective.—To evaluate how well small diagnostic biopsies and tissue microarrays (TMAs) reflect immune cell infiltration compared to the whole tumor slide, in tissue from patients with non–small cell lung cancer. Design.—A TMA was constructed comprising tissue from surgical resection specimens of 58 patients with non–small cell lung cancer, with available preoperative biopsy material. Whole sections, biopsies, and TMA were stained for the pan-T lymphocyte marker CD3 to determine densities of tumor-infiltrating lymphocytes. Immune cell infiltration was assessed semiquantitatively as well as objectively with a microscopic grid count. For 19 of the cases, RNA sequencing data were available. Results.—The semiquantitative comparison of immune cell infiltration between the whole section and the biopsy displayed fair agreement (intraclass correlation coefficient [ICC], 0.29; P ¼ .01; CI, 0.03–0.51). In contrast, the TMA showed substantial agreement compared with the whole slide (ICC, 0.64; P , .001; CI, 0.39–0.79). The grid-based method did not enhance the agreement between the different tissue materials. The comparison of CD3 RNA sequencing data with CD3 cell annotations confirmed the poor representativity of biopsies as well as the stronger correlation for the TMA cores. Conclusions.—Although overall lymphocyte infiltration is relatively well represented on TMAs, the representativity in diagnostic lung cancer biopsies is poor. This finding challenges the concept of using biopsies to establish immune scores as prognostic or predictive biomarkers for diagnostic applications.
  •  
7.
  •  
8.
  •  
9.
  • Hansson, Maire, et al. (författare)
  • Telomerase activity in effusions: a comparison between telomere repeat amplification protocol in situ and conventional telomere repeat amplification protocol assay.
  • 2008
  • Ingår i: Archives of pathology & laboratory medicine. - 1543-2165. ; 132:12, s. 1896-1902
  • Tidskriftsartikel (refereegranskat)abstract
    • CONTEXT: We previously found telomere repeat amplification protocol (TRAP) in situ helpful in the diagnosis of malignancy in effusions, whereas varying sensitivities and specificities for malignancy were reported by investigators using extract-based TRAP. OBJECTIVE: To compare the 2 methods and to elucidate the discrepancies between them. DESIGN: Twenty-three effusions were analyzed. Telomerase activity of whole cell lysate was measured with a Telo TAGGG telomerase polymerase chain reaction ELISA PLUS kit with modifications to exclude polymerase chain reaction inhibitors. TRAP in situ was performed on cytospins. An estimate of total TRAP activity in the specimen was made based on the amount of positive cells, their fluorescence intensity, and the proportion of different cell types in the specimen. The estimate was compared with the level of telomerase activity in cell lysate-based TRAP. RESULTS: TRAP in situ: Thirteen of 14 malignant cases and 2 of 2 equivocal cases showed moderate/strong reactivity. Five of 7 benign effusions were negative; in 2 of 7, mesothelial cells showed weak reactivity. Cell lysate-based TRAP assay: In 4 cases no internal standard was detected, indicating the presence of polymerase chain reaction inhibitors. The relative telomerase activities were 33.1 to 72.7 with a considerable overlap between malignant (48 +/- 9, mean +/- SD) and benign (43 +/- 9) cases. CONCLUSIONS: The TRAP in situ results correlated to final diagnoses, whereas the cell lysate-based TRAP assay did not differentiate between malignant and benign cases. The varying proportions of positive cells and the variation in fluorescence intensity in the TRAP in situ slides explained some of the discrepancies. The problems encountered with TRAP performed on cell lysates are partly overcome using TRAP in situ.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng