SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:2363 9075 "

Sökning: L773:2363 9075

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Amin, Rucha, et al. (författare)
  • Exploring the Link between Thermal Experience and Adaptation to a New Climate
  • 2018
  • Ingår i: Future Cities and Environment. - : Ubiquity Press, Ltd.. - 2363-9075 .- 2363-9075. ; 4:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Numerous field studies conducted in different locations have found that peoples’ thermal comfort varies with local climate. However, little is understood about the effect of moving from one climate to another. Literature suggests that people would be able to adapt to the typical indoor climate in a new location, though estimated timescales for this process differ. This paper uses data from a 6-month field study to investigate the process of thermal adaptation to a new climate. The field study consisted of a series of four thermal comfort surveys conducted with 48 occupants of single occupancy residential accommodation units, which helped to estimate their preferred temperatures. The surveys were carried out between October 2015 and April 2016 in Southampton, UK, with high resolution indoor air temperature data collected for the periods between the surveys. Study participants were grouped into three categories: long term residents of the UK (Category A), recently moved to the UK from cold climates (Category An) and recently moved to the UK from warm climates (Category B). The higher indoor temperatures of participants from cool climates (Category An) indicates the influence of indoor thermal history in determining thermal comfort conditions in a new location. This is highlighted by the fact that 94% of Category An participants reported having heating in their previous residence compared to 17% of Category B participants. Analysis of comfort temperatures over the first 6 months of occupancy shows no indication that occupants from Category An or B are adapting their indoor preferences to match that of long term UK residents, given the choice to create their preferred environment. Finally, comparison of indoor air temperature and comfort temperature found a higher correlation in Category A participants which supports the key principles of adaptive comfort theory. Category An demonstrated fairly close correlation though air temperatures were higher than comfort temperatures which may be due to embedded heater use behaviour patterns. Category B demonstrated no correlation between comfort temperature and air temperature which may be due to unfamiliarity to indoor heating systems.
  •  
2.
  • Aragon, Victoria, et al. (författare)
  • Evaluation of Retrofit Approaches for Two Social Housing Tower Blocks in Portsmouth, UK
  • 2018
  • Ingår i: Future Cities and Environment. - : Ubiquity Press, Ltd.. - 2363-9075. ; 4:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The UK aims to reduce its carbon emissions focusing on the renovation of its existing building stock, particularly on the residential sector. Within this group, social housing is an excellent candidate for retrofits, but faces specific challenges. The cases presented in this study are social housing tower blocks in the City of Portsmouth, which are destined to be retrofitted but present particularities within its architecture, heating system, and occupants’ behaviour and comfort perception. This study presents an analysis of the thermal performance of these buildings after different retrofit intervention scenarios were undertaken to evaluate heating loads, comfort and overheating. A dynamic simulation model was developed using the software TRNSYS and included performance evaluation under future climate change scenarios. Firstly, the buildings were modelled under different occupier energy profiles and the results in all cases, show that the physical properties of the building lead to a high level of energy consumption and discomfort. Moreover, the simulation of possible retrofits demonstrated that improving the building envelope to meet 2010 Building Regulations or stricter standards would result in a decrease of more than 80% of the heating load but would result in overheating if no adequate shading is installed. The analysis indicates that the best performing retrofit corresponded to a mixed system of MHRV for heating and natural ventilation during the summer. The paper concludes that (a) existing buildings are inefficient and a retrofit would result in a complete change in their energy performance and (b) that a thorough economic appraisal is required to select the best environmentally and economically viable interventions.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Teli, Despoina, 1980 (2)
James, Patrick (2)
Amin, Rucha (1)
Aragon, Victoria (1)
Lärosäte
Chalmers tekniska högskola (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Teknik (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy