1.
  • Hammarsten, Ola, et al. (författare)
  • Evaluation of a Sensitive Copeptin Assay for Clinical Measurement
  • 2012
  • Ingår i: The Open Clinical Chemistry Journal. - : Bentham Science Publishers Ltd.. - 2588-7785 .- 1874-2416. ; 5:1, s. 21-26
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract: Background: Copeptin, a marker of vasopressin production, has been introduced for earlier diagnosis of acute myocardial infarction and other clinical emergencies. We evaluated the analytical performance of a new generation copeptin assay in an inter-laboratory trial. Methods: Precision, linearity range, carry-over contamination, the limit of blank and an inter-laboratory comparison trial for the copeptin US KRYPTOR assay were performed on the B·R·A·H·M·S KRYPTOR compact PLUS. Results: The intra-assay imprecision (CVs) was 12.6–2.2% and total imprecision over five days was 12.3-4.3% between 3.1 and 18.2 pmol/L. The assay had excellent linearity between 7-222 pmol/L. The limit of blank was 2.5 pmol/L and the limit of detection was 3.2 pmol/L, but was dependent on the analyte-free material used. No significant difference between sample type, such as serum or different types of plasma or reagent lots, was noted. The copeptin results remained unchanged upon five repeated freeze-thaw cycles. A set of patient samples with a mean copeptin concentration of 2.1-61 pmol/L run at two separate sites showed close correlation (r2=0.99, slope=1.01, intercept=0.35), indicating comparable results across laboratories. Conclusion: The new ultrasensitive copeptin KRYPTOR assay shows excellent inter-lab precision, opening up the possibility for international guidelines to exclude acute myocardial infarction.
  •  
2.
  • Muslimovic, Aida, et al. (författare)
  • Calibrators for Clinical Measurements of Phosphorylated H2AX in Patient Cells by Flow Cytometry
  • 2012
  • Ingår i: The Open Clinical Chemistry Journal. - : Bentham Science Publishers Ltd.. - 2588-7785 .- 1874-2416. ; 5:1, s. 33-39
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract: Agents that induce DNA double-strand breaks (DSBs), such as ionizing radiation, are frequently used in cancer therapy. H2AX is rapidly phosphorylated in response to DSBs and serves as a way to measure the extent of DSBs induced in patient cells. We have previously reported a flow cytometry-based method for measuring H2AX phosphorylation in pa-tient cells undergoing radiotherapy. To be able to implement measurement of H2AX phosphorylation in clinical practice, we have characterized calibrators for the flow cytometry analysis based on phosphopeptide-coated beads and fixed cells. The calibrator beads and fixed cells lost less than 11% of the signal after storage for 40 days under optimal conditions and were able to correct for day-to-day variation in method performance.
  •  