SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:2638 6100 "

Sökning: L773:2638 6100

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dahlblom, Victor, et al. (författare)
  • Artificial intelligence detection of missed cancers at digital mammography that were detected at digital breast tomosynthesis
  • 2021
  • Ingår i: Radiology: Artificial Intelligence. - : Radiological Society of North America (RSNA). - 2638-6100. ; 3:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate how an artificial intelligence (AI) system performs at digital mammography (DM) from a screening population with ground truth defined by digital breast tomosynthesis (DBT), and whether AI could detect breast cancers at DM that had originally only been detected at DBT. Materials and Methods: In this secondary analysis of data from a prospective study, DM examinations from 14 768 women (mean age, 57 years), examined with both DM and DBT with independent double reading in the Malmӧ Breast Tomosynthesis Screening Trial (MBTST) (ClinicalTrials.gov: NCT01091545; data collection, 2010–2015), were analyzed with an AI system. Of 136 screening-detected cancers, 95 cancers were detected at DM and 41 cancers were detected only at DBT. The system identifies suspicious areas in the image, scored 1–100, and provides a risk score of 1 to 10 for the whole examination. A cancer was defined as AI detected if the cancer lesion was correctly localized and scored at least 62 (threshold determined by the AI system developers), therefore resulting in the highest examination risk score of 10. Data were analyzed with descriptive statistics, and detection performance was analyzed with receiver operating characteristics. Results: The highest examination risk score was assigned to 10% (1493 of 14 786) of the examinations. With 90.8% specificity, the AI system detected 75% (71 of 95) of the DM-detected cancers and 44% (18 of 41) of cancers at DM that had originally been detected only at DBT. The majority were invasive cancers (17 of 18). Conclusion: Almost half of the additional DBT-only screening-detected cancers in the MBTST were detected at DM with AI. AI did not reach double reading performance; however, if combined with double reading, AI has the potential to achieve a substantial portion of the benefit of DBT screening.
  •  
2.
  •  
3.
  • Langner, Taro, et al. (författare)
  • MIMIR : Deep Regression for Automated Analysis of UK Biobank MRI Scans
  • 2022
  • Ingår i: Radiology: Artificial Intelligence. - : Radiological Society of North America (RSNA). - 2638-6100. ; 4:3
  • Tidskriftsartikel (refereegranskat)abstract
    • UK Biobank (UKB) has recruited more than 500000 volunteers from the United Kingdom, collecting health-related information on genetics, lifestyle, blood biochemistry, and more. Ongoing medical imaging of 100 000 participants with 70 000 follow-up sessions will yield up to 170 000 MRI scans, enabling image analysis of body composition, organs, and muscle. This study presents an experimental inference engine for automated analysis of UKB neck-to-knee body 1.5-T MRI scans. This retrospective cross-validation study includes data from 38 916 participants (52% female; mean age, 64 years) to capture baseline characteristics, such as age, height, weight, and sex, as well as measurements of body composition, organ volumes, and abstract properties, such as grip strength, pulse rate, and type 2 diabetes status. Prediction intervals for each end point were generated based on uncertainty quantification. On a subsequent release of UKB data, the proposed method predicted 12 body composition metrics with a 3% median error and yielded mostly well-calibrated individual prediction intervals. The processing of MRI scans from 1000 participants required 10 minutes. The underlying method used convolutional neural networks for image-based mean-variance regression on two-dimensional representations of the MRI data. An implementation was made publicly available for fast and fully automated estimation of 72 different measurements from future releases of UKB image data. (C) RSNA, 2022.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy