1.
  • Mocchiutti, E., et al. (författare)
  • Precision studies of cosmic rays with the PAMELA satellite experiment
  • 2009
  • Ingår i: 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5. - : IEEE. - 9781424439621 ; , s. 2125-2130
  • Konferensbidrag (refereegranskat)abstract
    • The PAMELA satellite experiment was launched into low earth orbit on June 15th 2006. The combination of a permanent magnet silicon strip spectrometer, and a silicon-tungsten imaging calorimeter allows precision studies of the charged cosmic radiation to be conducted over a wide energy range (100 MeV - 200 GeV). A primary scientific goal is to search for dark matter particle annihilations by measuring the energy spectra of cosmic ray antiparticles. Latest results from the PAMELA experiment will be reviewed with a particular focus on cosmic ray antiprotons and positrons. The status of PAMELA measurements for other cosmic ray species will also be reviewed.
  •  
2.
  • Norlin, Börje, 1967-, et al. (författare)
  • Energy Resolved X-ray Imaging as a Tool for Characterization of Paper Coating Quality
  • 2009
  • Ingår i: IEEE Nuclear Science Symposium Conference Record 2009. - : IEEE conference proceedings. - 9781424439621 ; , s. 1703-1706
  • Konferensbidrag (refereegranskat)abstract
    • Energy resolved X-ray imaging can be used as a tool to analyze the variation in the chemical content of an object. In this work we have used energy resolved X-ray imaging to measure the variation in the chemical content of paper and paper coating. This is an important quality parameter for the paper industry. In order to separate the variation in coating thickness from the variation in paper thickness, energy resolution is used to separate the response of the coating from the response of the paper. The MEDIPIX2 single photon processing X-ray imaging system [1] has been used in the measurements.  The measurement results are compared to simulations with MCNP. The influence of charge sharing is discussed and the effects have been studied by comparing results from detectors with 220x220 µm2 pixels and detectors with 55x55 µm2 pixels. There is a trade-off between good spatial resolution obtained with detectors with small pixels and good energy resolution obtained with detectors with large pixels. The requirements on image quality, to achieve the resolution of coating distribution relevant for the application, are discussed.
  •  