  • Diczfalusy, Elin, et al. (författare)
  • Simulations and visualizations for interpretation of brain microdialysis data during deep brain stimulation
  • 2012
  • Ingår i: IEEE Engineering in Medicine and Biology Society (EMBC), 2012. - : IEEE. - 9781424441198 - 9781424441204 - 9781457717871 ; , s. 6438-6441
  • Konferensbidrag (refereegranskat)abstract
    • Microdialysis of the basal ganglia was used in parallel to deep brain stimulation (DBS) for patients with Parkinson’s disease. The aim of this study was to patientspecifically simulate and visualize the maximum tissue volume of influence (TVImax) for each microdialysis catheter and the electric field generated around each DBS electrode. The finite element method (FEM) was used for the simulations. The method allowed mapping of the anatomical origin of the microdialysis data and the electric stimulation for each patient. It  was seen that the sampling and stimulation targets differed among the patients, and the results will therefore be used in the future interpretation of the biochemical data.
  •  
2.
  • Rejmstad, Peter, et al. (författare)
  • A laser Doppler system for monitoring of intracerebral microcirculation
  • 2012
  • Ingår i: Conf Proc IEEE Eng Med Biol Soc.. - : IEEE. - 1557-170X. - 9781424441198 - 9781457717871 ; , s. 1988-1991
  • Tidskriftsartikel (refereegranskat)abstract
    • A two-channel standard laser Doppler perfusion monitor has been adapted for intracerebral measurements. Software developed in Labview makes it possible to present the microvascular perfusion, total light intensity (TLI), heart rate and trend curves in real-time during surgery. A custom-made optical probe was designed in order to enable easy fixation during brain surgery. The constructed brain probe was evaluated and compared to a standard probe. Both probes presented similar feasibility when used for the skin recordings. In addition, evaluation was done in one patient in relation to tumor resection. Stable perfusion and TLI signals were immediately recorded when the probe was positioned in cerebral tissue. Movement artifacts were clearly seen when the probe was moved to a new site. Recordings in cortex and tumor border showed higher perfusion and lower TLI compared to measurements in subcortical white matter. The calculated heart rate estimate agreed well with the noted value from the electrocardiographic patient monitoring system.                                                                                                                                                      
  •  
3.
  • Abualhoul, Mohammad Y., et al. (författare)
  • Free space optical link for biomedical applications
  • 2012
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - 1557-170X. - 9781424441198 ; , s. 1667-1670
  • Konferensbidrag (refereegranskat)abstract
    • Free space optics is an interesting alternative for telemetry with medical implants, due to the high data bandwidths available at optical frequencies. Especially implanted brain-computer interfaces gives rise to large data sets that needs to be transmitted transcutaneous. In this paper we show that it is possible to establish such a link at near-IR wavelengths using a modulated reflector in the implant, thus keeping the laser and the detector on the outside. In addition, we show that it will not only work on short, i.e. touch, distances but also at larger distances, in the range of a meter. We have used an electro absorption modulator to modulate the reflection of an external laser source back towards an external detector. The only part of this system that needs to be implanted is the modulator and drive electronics. The study has been done both by Monte-Carlo simulations of a multi-layer model of a rat skull, and with an experiment demonstrating the feasibility of the link when transmitted through biological tissue. The results show that it is possible to establish a transcutaneous link with an external laser source and light detector, and an internal modulated reflector.
  •  
4.
  • Atefi, Seyed Reza, 1985-, et al. (författare)
  • Electrical Bioimpedance cerebral monitoring. Preliminary results from measurements on stroke patients
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; 2012, s. 126-9
  • Konferensbidrag (refereegranskat)abstract
    • Electrical Bioimpedance Spectroscopy (EBIS) is currently used in different tissue characterization applications. In this work we aim to use EBIS to study changes in electrical properties of the cerebral tissues after an incident of hemorrhage/ischemic stroke. To do so a case-control study was conducted using six controls and three stroke cases. The preliminary results of this study show that by using Cole-based analysis on EBIS measurements and analyzing the Cole parameters R0 and R∞, it is possible to detect changes on electrical properties of cerebral tissue after stroke. 
  •  
5.
  • Chandra, Rohit, et al. (författare)
  • Effect of Frequency, Body Parts and Surrounding on the On-Body Propagation Channel Around the Torso
  • 2012
  • Ingår i: 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. - 9781424441198
  • Konferensbidrag (refereegranskat)abstract
    • Wearable medical devices can be positioned around the torso for monitoring of critical health parameters. The signal transmission between them is through a wireless link over an on-body propagation channel. In this paper, the effect of some factors which could influence the propagation channel around the torso as: (a) frequency of operation (b) positions of the arms (c) material of a chair used, have been investigated. Moreover, a comparison between the link loss around the torso of a full body phantom and a truncated torso phantom has been done. It is found that the frequency of operation and the positions of the arms have a significant influence on the channel. The difference between the link loss of a full body phantom and a truncated phantom is found to be minimal, indicating a possibility of using a truncated torso for a faster simulation. The results presented in the paper gives an insight in to the influence of arms and the frequency of operation on the propagation channel around the torso and thus would be beneficial for designing a reliable wireless link.
  •  
6.
  • Garcia-Molina, G., et al. (författare)
  • Automated NREM sleep staging using the Electro-oculogram : A pilot study
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; , s. 2255-2258
  • Konferensbidrag (refereegranskat)abstract
    • Automatic sleep staging from convenient and unobtrusive sensors has received considerable attention lately because this can enable a large range of potential applications in the clinical and consumer fields. In this paper the focus is on achieving non-REM (NREM) sleep staging from ocular electrodes. From these signals, specific patterns related to sleep such as slow eye movements, K-complexes, eye blinks, and spectral features are estimated. Although such patterns are characteristic of the Electroencephalogram, they can also be visible to a lesser extent on signals from ocular electrodes. Automatic sleep staging was implemented using two approaches: i) based on a state-machine and ii) using a neural network. The first one relied on the recommendations of the American Academy of Sleep Medicine, and the second one used a multilayer perceptron which was trained on manually sleep-staged data. Results were obtained on the data of five volunteers who participated in a nap experiment. Manual sleep staging of this data, performed by an expert, was used as reference. Five stages were considered, namely wake with eyes open, wake with eyes closed, and sleep stages N1, N2, and N3. The results were characterized in terms of confusion matrices from which the Cohen's κ coefficients were estimated. The values of κ for both the state-machine and neural-network based automatic sleep staging approaches were 0.79 and 0.59 respectively. Thus, the state-machine based approach shows a very good agreement with manual staging of sleep-data.
  •  
7.
  • Moshavegh, Ramin, et al. (författare)
  • Automated segmentation of free-lying cell nuclei in Pap smears for malignancy-associated change analysis
  • 2012
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - 1557-170X. - 9781424441198 ; , s. 5372-5375
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents an automated algorithm for robustly detecting and segmenting free-lying cell nuclei in bright-field microscope images of Pap smears. This is an essential initial step in the development of an automated screening system for cervical cancer based on malignancy associated change (MAC) analysis. The proposed segmentation algorithm makes use of gray-scale annular closings to identify free-lying nuclei-like objects together with marker-based watershed segmentation to accurately delineate the nuclear boundaries. The algorithm also employs artifact rejection based on size, shape, and granularity to ensure only the nuclei of intermediate squamous epithelial cells are retained. An evaluation of the performance of the algorithm relative to expert manual segmentation of 33 fields-of-view from 11 Pap smear slides is also presented. The results show that the sensitivity and specificity of nucleus detection is 94.71% and 85.30% respectively, and that the accuracy of segmentation, measured using the Dice coefficient, of the detected nuclei is 97.30±1.3%.
  •  
8.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Adaptive frequency distribution for Electrical Bioimpedance Spectroscopy measurements
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; 2012, s. 562-5
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a novel frequency distribution scheme intended to provide more accurate estimations of Cole parameters. Nowadays a logarithmic frequency distribution is mostly used in Electrical Bioimpedance Spectroscopy (EBIS) applications. However it is not optimized following any criterion. Our hypothesis is that an EBIS signal contains more information where the variation of the measurement regarding the frequency is larger; and that there ought to be more measuring frequencies where there is more information. Results show that for EBIS data with characteristic frequencies up to 200 kHz the error obtained with both frequency distribution schemes is similar. However, for EBIS data with higher values of characteristic frequency the error produced when estimating the values from EBIS measurements using an adaptive frequency distribution is smaller. Thus it may useful for EBIS applications with high values of characteristic frequency, e.g. cerebral bioimpedance.
  •  
9.
  • Shirvany, Yazdan, 1980, et al. (författare)
  • Non-invasive EEG source localization using particle swarm optimization: A clinical experiment
  • 2012
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - 1557-170X. - 9781424441198 ; , s. 6232-6235
  • Konferensbidrag (refereegranskat)abstract
    • One of the most important steps of pre-surgical diagnosis in patients with medically intractable epilepsy is to find the precise location of the epileptogenic foci. An Electroencephalography (EEG) is a non-invasive standard tool used at epilepsy surgery center for pre-surgical diagnosis. In this paper a modified particle swarm optimization (MPSO) method is applied to a real EEG data, i.e., a somatosensory evoked potentials (SEPs) measured from a healthy subject, to solve the EEG source localization problem. A high resolution 1 mm hexahedra finite element volume conductor model of the subject's head was generated using T1-weighted magnetic resonance imaging data. An exhaustive search pattern and the MPSO method were then applied to the peak of the averaged SEPs data. The non-invasive EEG source analysis methods localized the somatosensory cortex area where our clinical expert expected the received SEPs. The proposed inverse problem solver found the global minima with acceptable accuracy and reasonable number of iterations.
  •  
10.
  • Xie, Li, et al. (författare)
  • A system-on-chip and paper-based inkjet printed electrodes for a hybrid wearable bio-sensing system
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; , s. 5026-5029
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a hybrid wearable bio-sensing system, which combines traditional small-area low-power and high-performance System-on-Chip (SoC), flexible paper substrate and cost-effective Printed Electronics. Differential bio-signals are measured, digitized, stored and transmitted by the SoC. The total area of the chip is 1.5 × 3.0 mm2. This enables the miniaturization of the wearable system. The electrodes and interconnects are inkjet printed on paper substrate and the performance is verified in in-vivo tests. The quality of electrocardiogram signal sensed by printed electrodes is comparable with commercial electrodes, with noise level slightly increased. The paper-based inkjet printed system is flexible, light and thin, which makes the final system comfortable for end-users. The hybrid bio-sensing system offers a potential solution to the next generation wearable healthcare technology.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy