1.
  •  
2.
  • Baig, M.M., et al. (författare)
  • Tablet-based Patient Monitoring and Decision Support Systems in Hospital Care
  • 2015
  • Ingår i: 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC). - 9781424492701 ; , s. 1215-1218
  • Konferensbidrag (refereegranskat)abstract
    • Remote patient monitoring with evidence-based decision support is revolutionizing healthcare. This novel approach could enable both patients and healthcare providers to improve quality of care and reduce costs. Clinicians can also view patients' data within the hospital network on tablet computers as well as other ubiquitous devices. Today, a wide range of applications are available on tablet computers which are increasingly integrating into the healthcare mainstream as clinical decision support systems. Despite the benefits of table-based healthcare applications, there are concerns around the accuracy, security and stability of such applications. In this study, we developed five tablet-based application screens for remote patient monitoring at hospital care settings and identified related issues and challenges. The ultimate aim of this research is to integrate decision support algorithms into the monitoring system in order to improve inpatient care and the effectiveness of such applications.
  •  
3.
  • Hamed, Zaid, et al. (författare)
  • A Programmable Low Power Current Source for Bioimpedance Measurement : Towards a Wearable Personalized Health
  • 2015
  • Ingår i: 2015 37th Annual International Conference of The IEEE ENGINEERING in Medicine and Biology Society (EMBC). - 9781424492701 ; , s. 2038-2042
  • Konferensbidrag (refereegranskat)abstract
    • Bioimpedance is a noninvasive measurement method that facilitates body composition analysis, besides being indicative of many other health parameters. In this work a novel programmable, low complexity, high output impedance, high voltage compliance and wideband current source for bioimpedance applications is presented. Previously, we designed, fabricated and tested in vivo a bio-patch for acquisition of multiple bio-signals [1]. Upon integration with our previous work, this circuit is envisioned to constitute part of a personalized health assistant. Simulation at worst case corners and real operation conditions was carried out using UMC-180 nm 1 poly 6 metal CMOS process. Full duty cycle, shortened or stepped square waves can be generated. Amplitude control of 8 different current levels is supported. Frequency can be tuned up to 1 MHz and an output impedance of 2.8 MO @ 250 KHz is achieved at full current capacity. Total current consumption is comparable to the injected current, making the circuit highly efficient.
  •  
4.
  • Seoane, Fernando, et al. (författare)
  • Slightly superior performance of bioimpedance spectroscopy over single frequency regression equations for assessment of total body water.
  • 2015
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE. 25-29 Aug. 2015, Milan, Italy.. - : IEEE. - 1094-687X .- 1558-4615. - 9781424492718 - 9781424492701 ; 2015, s. 3707-10
  • Konferensbidrag (refereegranskat)abstract
    • Electrical bioimpedance has been used for several decades to assess body fluid distribution and body composition by using single frequency and bioimpedance spectroscopic (BIS) techniques. It remains uncertain whether BIS methods have better performance compare to single frequency regression equations. In this work the performance of two BIS methods and four different 50 kHz single frequency prediction equations was studied in a data set of wrist-to-ankle tetrapolar BIS measurements (5-1000 kHz) together with reference values of total body water obtained by tritium dilution in 92 patients. Data were compared using regression techniques and Bland-Altman plots. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Limits of agreement analysis indicated that the population level performance of Sun's prediction equations was very similar to the performance of both BIS methods. However, BIS methods in practice have slightly better predictive performance than the single-frequency equations as judged by higher correlation and the limits of agreement from the Bland-Altman analysis. In any case, the authors believe that an accurate evaluation of performance of the methods cannot be done as long as the evaluation is done using Bland-Altman analysis, the commonly accepted technique for this kind of performance comparisons.
  •  