SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Àbalos Manuela) "

Sökning: WFRF:(Àbalos Manuela)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abad, Esteban, et al. (författare)
  • Air monitoring with passive samplers for dioxin-like persistent organic pollutants in developing countries (2017-2019)
  • 2021
  • Ingår i: Chemosphere. - : Pergamon Press. - 0045-6535 .- 1879-1298. ; 287:Pt 1
  • Tidskriftsartikel (refereegranskat)abstract
    • As part of the global monitoring plan on persistent organic pollutants (GMP) under the Stockholm Convention passive air samplers equipped with polyurethane foam disks (PUFs) were applied to monitor dioxin-like POPs. For sampling, toluene-pretreated PUFs were exposed for three months during two years. Chemical analysis was performed in one accredited expert laboratory using internationally accepted methods; for comparison, all results were normalized to one PUF and 3 month exposure. Total TEQs, using WHO2005-TEFs, were lowest in the Pacific Islands countries (PAC) and had similar mean values in Africa (16.8 pg TEQ/PUF), Asia (16.9 pg TEQ/PUF), and Latin American and Caribbean countries (GRULAC, 13.3 pg TEQ/PUF). Using median values, Asia (13.4 pg TEQ/PUF) and GRULAC (13.1 pg TEQ/PUF) had higher amounts than Africa (6.1 pg TEQ/PUF) and PAC (2.1 pg TEQ/PUF). The contribution of PCDD/PCDF to the total TEQ was 2-3-times higher than from the dl-PCB. Mono-ortho PCB did not play a role in any of the samples. The previous 40 samples during 2010/2011 and the present 195 samples from 2017/2018 did not show a statistical difference (p value = 0.3), only for GRULAC, a downward trend was identified. It is recommended combining 4 PUFs to ‘annual’ samples.
  •  
2.
  • Fiedler, Heidelore, Dr. 1953-, et al. (författare)
  • Dioxin-like POPs in national samples from global monitoring plan projects (2017-2019)
  • 2023
  • Ingår i: Chemosphere. - : Pergamon Press. - 0045-6535 .- 1879-1298. ; 325
  • Tidskriftsartikel (refereegranskat)abstract
    • The global monitoring plan (GMP) established under the Stockholm Convention on Persistent Organic Pollutants (POPs) had defined ambient air, human milk or blood, and water as core matrices to be analyzed and assessed for spatial and temporal distribution. Within projects coordinated by the United Nations Environment Programme (UNEP), developing countries were offered to have other matrices analyzed for dioxin-like POPs (dl-POPs) in experienced laboratories. Subsequently, 185 samples from 27 countries located in Africa, Asia, and Latin America were collected during 2018-2019 and analyzed for polychlorinated dibenzodioxins (PCDD), dibenzofurans (PCDF), and biphenyls (PCB). Using the WHO2005 toxic equivalency approach (TEQ), the amounts of dl-POPs found were low (<1 pg TEQ/g); however, singular samples had higher values; e.g., egg from Morocco, fish from Argentina or Tunisia; soil and sediment samples. Results showed that the matrix, abiotic or biota, had more impact on the TEQ pattern than the geographic location. Independent of the location and across all samples, dl-PCB in (shell)fish and beef samples had a contribution of 75% to the total TEQ; milk (63%), chicken (52%), and butter (50.2%) more than 50%. Sediment (57% and 32%) and soil (40% and 36%)) samples were dominated by PCDD and PCDF, respectively; therein, dl-PCB had shares of 11% and 24%. Egg samples (N = 27) did not follow the general biota pattern and had 21% of the TEQ from the PCDD, 45% from PCDF, and 34% from dl-PCB; thus, indicating that abiotic matrices such as soil or other material may have an impact.
  •  
3.
  •  
4.
  • Sales, Carlos, et al. (författare)
  • Potential of gas chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry for screening and quantification of hexabromocyclododecane
  • 2016
  • Ingår i: Analytical and Bioanalytical Chemistry. - Heidelberg, Germany : Springer. - 1618-2642 .- 1618-2650. ; 408:2, s. 449-459
  • Tidskriftsartikel (refereegranskat)abstract
    • A fast method for the screening and quantification of hexabromocyclododecane (sum of all isomers) by gas chromatography using a triple quadrupole mass spectrometer with atmospheric pressure chemical ionization (GC-APCI-QqQ) is proposed. This novel procedure makes use of the soft atmospheric pressure chemical ionization source, which results in less fragmentation of the analyte than by conventional electron impact (EI) and chemical ionization (CI) sources, favoring the formation of the [M - Br](+) ion and, thus, enhancing sensitivity and selectivity. Detection was based on the consecutive loses of HBr from the [M - Br](+) ion to form the specific [M - H5Br6](+) and [M - H4Br5](+) ions, which were selected as quantitation (Q) and qualification (q) transitions, respectively. Parameters affecting ionization and MS/MS detection were studied. Method performance was also evaluated; calibration curves were found linear from 1 pg/mu L to 100 pg/mu L for the total HBCD concentration; instrumental detection limit was estimated to be 0.10 pg/mu L; repeatability and reproducibility, expressed as relative standard deviation, were better than 7 % in both cases. The application to different real samples [polyurethane foam disks (PUFs), food, and marine samples] pointed out a rapid way to identify and allow quantification of this compound together with a number of polybrominated diphenyl ethers (BDE congeners 28, 47, 66, 85, 99, 100, 153, 154, 183, 184, 191, 196, 197, and 209) and two other novel brominated flame retardants [i.e., decabromodiphenyl ethane (DBDPE) and 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE)] because of their presence in the same fraction when performing the usual sample treatment.
  •  
5.
  • van Bavel, Bert, 1963-, et al. (författare)
  • Atmospheric-Pressure Chemical Ionization Tandem Mass Spectrometry (APGC/MS/MS) an Alternative to High-Resolution Mass Spectrometry (HRGC/HRMS) for the Determination of Dioxins
  • 2015
  • Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 87:17, s. 9047-9053
  • Tidskriftsartikel (refereegranskat)abstract
    • The use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described. The potential of using atmospheric-pressure chemical ionization (APCI) coupled to a tandem quadrupole analyzer has been validated for the identification and quantification of dioxins and furans in different complex matrices. The main advantage of using the APCI source is the soft ionization at atmospheric pressure, which results in very limited fragmentation. APCI mass spectra are dominated by the molecular ion cluster, in contrast with the high energy ionization process under electron ionization (El). The use of the molecular ion as the precursor ion in MS/MS enhances selectivity and, consequently, sensitivity by increasing the signal-to-noise ratios (S/N). For standard solutions of 2,3,7,8-TCDD, injections of 10 fg in the splitless mode on 30- or 60-m-length, 0.25 mm inner diameter (id), and 25 mu m film thickness low-polarity capillary columns (DB5MS type), signal-to-noise (S/N) ratios of >10:1 were routinely obtained. Linearity was achieved in the region (correlation coefficient of r(2) > 0.998) for calibration curves ranging from 100 fg/mu L, to 1000 pg/mu L. The results from a wide variety of complex samples, including certified and standard reference materials and samples from several QA/QC studies, which were previously analyzed by EI HRGC/HRMS, were compared with the results from the APGC/MS/MS system. Results between instruments showed good agreement both in individual congeners and toxic equivalence factors (TEQs). The data show that the use of APGC in combination with MS/MS for the analysis of dioxins has the same potential, in terms of sensitivity and selectivity, as the traditional HEMS instrumentation used for this analysis. However, the APCI/MS/MS system, as a benchtop system, is much easier to use.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy