SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Öhrnell Lars Olov) "

Sökning: WFRF:(Öhrnell Lars Olov)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kahnberg, Karl-Erik, 1941, et al. (författare)
  • Clinical evaluation of the zygoma implant : 3-year follow-up at 16 clinics
  • 2007
  • Ingår i: Journal of oral and maxillofacial surgery (Print). - : Elsevier BV. - 0278-2391 .- 1531-5053. ; 65:10, s. 2033-2038
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of this clinical investigation was to evaluate the treatment outcome with zygoma implants with regard to implant survival, patient satisfaction, and function of prosthesis replacement after 3 years. Patients and Methods: The treatment outcome of 76 patients treated with 145 zygoma fixtures at 16 centers was evaluated with regard to implant survival. Status of peri-implant mucosa and amount of plaque were registered annually. Patients' and dentists' evaluations of the functional and esthetic outcome of the treatment were assessed at delivery of prosthesis and thereafter at each follow-up visit. Results: Sixty of 76 patients were followed for 3 years after prosthetic delivery. Five of 145 placed zygoma implants failed during the course of the study resulting in an overall implant survival rate of 96.3%. At the 3-year follow-up, 75% of the implants sites were registered with normal peri-implant mucosa and 68% with no visible plaque. The patients were fully satisfied with the esthetic and functional outcome of the treatment in 86% and 71%, respectively, at the 3-year follow-up visit. All reported data from dentists scored from acceptable to excellent. Conclusion: The multicenter study showed a high predictability of the zygoma implant-supported rehabilitation.
  •  
2.
  • Brånemark, Per-Ingvar, et al. (författare)
  • Zygoma fixture in the management of advanced atrophy of the maxilla: technique and long-term results.
  • 2004
  • Ingår i: Scandinavian journal of plastic and reconstructive surgery and hand surgery / Nordisk plastikkirurgisk forening [and] Nordisk klubb for handkirurgi. - : Informa UK Limited. - 0284-4311. ; 38:2, s. 70-85
  • Tidskriftsartikel (refereegranskat)abstract
    • Despite refinements in surgical technique, including bone grafting and sophisticated prosthetic reconstructions, there are limitations to what can be achieved with bone-anchored fixed prostheses in patients with advanced atrophy of the maxillae. A new approach was suggested by a long-term study on onlay bone grafting and simultaneous placement of a fixture based on a new design: the zygoma fixture, and the aim of this study was to assess its potential. Twenty-eight consecutive patients with severely resorbed edentulous maxillae were included, 13 of whom had previously had multiple fixture surgery in the jawbone that had failed. A total of 52 zygoma fixtures and 106 conventional fixtures were installed. Bone grafting was deemed necessary in 17 patients. All patients have been followed for at least five years, and nine for up to 10 years. All patients were followed up with clinical and radiographic examinations, and in some cases rhinoscopy and sinoscopy as well. Three zygoma fixtures failed; two at the time of connection of the abutment and the third after six years. Of the conventional fixtures placed at the time of the zygoma fixture, 29 (27%) were lost. The overall prosthetic rehabilitation rate was 96% after at least five years of function. There were no signs of inflammatory reaction in the surrounding antral mucosa. Four patients with recurrent sinusitis recovered after inferior meatal antrostomy. To conclude, the zygoma fixture seems to be a valuable addition to our repertoire in the management of the compromised maxilla.
  •  
3.
  • Brånemark, Rickard, 1960, et al. (författare)
  • Biomechanical characterization of osseointegration: an experimental in vivo investigation in the beagle dog.
  • 1998
  • Ingår i: Journal of orthopaedic research : official publication of the Orthopaedic Research Society. - : Wiley. - 0736-0266. ; 16:1, s. 61-9
  • Tidskriftsartikel (refereegranskat)abstract
    • This study reports the results of torsion tests, pull-out tests, and lateral loading tests on osseointegrated commercially pure titanium fixtures. The tests were performed in vivo on six beagle dogs. Three fixtures, each with a diameter of 3.7 mm, were installed bilaterally in the tibia of each animal. The mean maximal pull-out load was 1.55 kN (n = 4), the mean maximal lateral transverse load was 0.21 kN (n = 2), the mean maximal lateral axial load was 0.18 kN (n = 2), the mean breakpoint torque was 0.31 Nm (n = 3), and the mean maximal torque was 0.43 Nm (n = 3). The torsion test revealed an almost immediate plastic deformation of the interface between the implant and bone; this indicates that although the contact between the bone and the implant is close, there is no strong bond, at least not in shear. The major transfer of load from the implant to the surrounding bone tissue must therefore depend on the design of the implant. A histological evaluation with measurements of the amount of bone in contact with the fixtures was performed. By the use of the histological and mechanical data, it is possible to estimate shear stresses in bone tissue (pull-out test) and in the interface (torque test). The mean maximal shear stress in bone tissue in the pull-out tests was 100 MPa (n = 4); the mean shear stress in the interface was 4.3 MPa (n = 3) in the torsion tests at the breakpoint torque and was 6.0 MPa (n = 3) at the maximal torque. It was also possible to estimate the shear modulus of elasticity in the pull-out and torque tests. The mean shear modulus in pull-out was 119 MPa (n = 4), and the mean apparent shear modulus in torsion was 9 kPa (n = 3) for an assumed interface thickness of 100 nm and was 86 kPa (n = 3) for an assumed interface thickness of 1,000 nm.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy