SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Aase Hildegunn S.) "

Sökning: WFRF:(Aase Hildegunn S.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Moshina, Nataliia, et al. (författare)
  • Comparing screening outcomes for digital breast tomosynthesis and digital mammography by automated breast density in a randomized controlled trial : Results from the to-be trial
  • 2020
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 0033-8419 .- 1527-1315. ; 297:3, s. 522-531
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Digital breast tomosynthesis (DBT) is considered superior to digital mammography (DM) for women with dense breasts. Purpose: To identify differences in screening outcomes, including rates of recall, false-positive (FP) findings, biopsy, cancer detection rate, positive predictive value of recalls and biopsies, and histopathologic tumor characteristics by density using DBT combined with two-dimensional synthetic mammography (SM) (hereafter, DBT+SM) versus DM. Materials and Methods: This randomized controlled trial comparing DBT+SM and DM was performed in Bergen as part of BreastScreen Norway, 2016-2017. Automated software measured density (Volpara Density Grade [VDG], 1-4). The outcomes were compared for DBT+SM versus DM by VDG in descriptive analyses. A stratified log-binomial regression model was used to estimate relative risk of outcomes in subgroups by screening technique. Results: Data included 28 749 women, 14 380 of whom were screened with DBT+SM and 14 369 of whom were screened with DM (both groups: median age, 59 years; interquartile range [IQR], 54-64 years). The recall rate was lower for women screened with DBT+SM versus those screened with DM for VDG 1 (2.1% [81 of 3929] vs 3.3% [106 of 3212]; P = .001) and VDG 2 (3.2% [200 of 6216] vs 4.3% [267 of 6280]; P = .002). For DBT+SM, adjusted relative risk of recall (VDG 2: 1.8; P < .001; VDG 3: 2.4; P < .001; VDG 4: 1.8; P = .02) and screen-detected breast cancer (VDG 2: 2.4; P = .004; VDG 3: 2.8; P = .01; VDG 4: 2.8; P = .05) increased with VDG, whereas no differences were observed for DM (relative risk of recall for VDG 2: 1.3; P = .06; VDG 3: 1.1; P = .41; VDG 4: 1.1; P = .71; and relative risk of screen-detected breast cancer for VDG 2: 1.7; P = .13; VDG 3: 2.1; P = .06; VDG 4: 2.2; P = .15). Conclusion: Screening with digital breast tomosynthesis combined with synthetic two-dimensional mammograms (DBT+SM) versus digital mammography (DM) yielded lower recall rates for women with Volpara Density Grade (VDG) 1 and VDG 2. Adjusted relative risk of recall and screen-detected breast cancer increased with denser breasts for DBT+SM but not for DM.
  •  
2.
  • Moshina, Nataliia, et al. (författare)
  • Digital breast tomosynthesis in mammographic screening : false negative cancer cases in the To-Be 1 trial
  • 2024
  • Ingår i: Insights into Imaging. - 1869-4101. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The randomized controlled trial comparing digital breast tomosynthesis and synthetic 2D mammograms (DBT + SM) versus digital mammography (DM) (the To-Be 1 trial), 2016–2017, did not result in higher cancer detection for DBT + SM. We aimed to determine if negative cases prior to interval and consecutive screen-detected cancers from DBT + SM were due to interpretive error. Methods: Five external breast radiologists performed the individual blinded review of 239 screening examinations (90 true negative, 39 false positive, 19 prior to interval cancer, and 91 prior to consecutive screen-detected cancer) and the informed consensus review of examinations prior to interval and screen-detected cancers (n = 110). The reviewers marked suspicious findings with a score of 1–5 (probability of malignancy). A case was false negative if ≥ 2 radiologists assigned the cancer site with a score of ≥ 2 in the blinded review and if the case was assigned as false negative by a consensus in the informed review. Results: In the informed review, 5.3% of examinations prior to interval cancer and 18.7% prior to consecutive round screen-detected cancer were considered false negative. In the blinded review, 10.6% of examinations prior to interval cancer and 42.9% prior to consecutive round screen-detected cancer were scored ≥ 2. A score of ≥ 2 was assigned to 47.8% of negative and 89.7% of false positive examinations. Conclusions: The false negative rates were consistent with those of prior DM reviews, indicating that the lack of higher cancer detection for DBT + SM versus DM in the To-Be 1 trial is complex and not due to interpretive error alone. Critical relevance statement: The randomized controlled trial on digital breast tomosynthesis and synthetic 2D mammograms (DBT) and digital mammography (DM), 2016–2017, showed no difference in cancer detection for the two techniques. The rates of false negative screening examinations prior to interval and consecutive screen-detected cancer for DBT were consistent with the rates in prior DM reviews, indicating that the non-superior DBT performance in the trial might not be due to interpretive error alone. Key points: • Screening with digital breast tomosynthesis (DBT) did not result in a higher breast cancer detection rate compared to screening with digital mammography (DM) in the To-Be 1 trial. • The false negative rates for examinations prior to interval and consecutive screen-detected cancer for DBT were determined in the trial to test if the lack of differences was due to interpretive error. • The false negative rates were consistent with those of prior DM reviews, indicating that the lack of higher cancer detection for DBT versus DM was complex and not due to interpretive error alone. Graphical Abstract: (Figure presented.)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy